Human Factors Engineering Program Review Model (NUREG-0711, Revision 3)
On this page:
Download complete document
Publication Information
Manuscript Completed: September 2012
Date Published: November 2012
Prepared by:
J.M. O'Hara*, J.C. Higgins*
S. A. Fleger, P. A. Pieringer
*Brookhaven National Laboratory
Energy Sciences and Technology Department
Upton, NY 11973-5000
S. A. Fleger, NRC Project Manager
NRC Job Code Number N6765
Office of Nuclear Reactor Regulation,
U.S. Nuclear Regulatory Commission,
Washington, D.C. 20555-0001
Abstract
This document is used by the staff of the Nuclear Regulatory Commission to review the human factors engineering (HFE) programs of applicants for construction permits, operating licenses, standard design certifications, combined operating licenses, and license amendments. The purpose of these reviews is to verify that the applicant’s HFE program incorporates HFE practices and guidelines accepted by the staff as described within the twelve elements of an HFE program: HFE Program Management, Operating Experience Review, Functional Requirements Analysis and Function Allocation, Task Analysis, Staffing and Qualifications, Treatment of Important Human Actions, Human-System Interface Design, Procedure Development, Training Program Development, Human Factors Verification and Validation, Design Implementation, and Human Performance Monitoring. Each element encompasses five sections: Background, Objective, Applicant Products and Submittals, Review Criteria, and Bibliography.
Page Last Reviewed/Updated Wednesday, April 30, 2025
Page Last Reviewed/Updated Wednesday, April 30, 2025