Issue Date: 01/17/02
NRC Inspection Manual IIPB
To establish the policy for the light-water operating reactor inspection program.
| 02.01 | To obtain factual information providing objective evidence that power reactor facilities are operated safely and licensee activities do not pose an undue risk to public health and safety. |
| 02.02 | To determine the causes of declining performance before such performance reaches a level that may result in an undue risk to public health and safety. |
| 02.03 | To identify those safety significant issues that may have generic applicability. |
This inspection program is implemented when an operating license is issued for a facility. Portions of the light-water reactor inspection program for the startup phase (IMC 2514) may also be conducted during the initial operation of a facility. The light-water reactor inspection program for the preoperational testing and operational preparedness phase (IMC 2513) will have been completed by the time this program is in effect.
This inspection program will remain in effect until the facility is permanently shut down and enters the post-operational phase (cf, IMC 2561, "Decommissioning Power Reactor Inspection Program").
| 04.01 | Triennially or Every Three Years (T). The inspection effort should be performed every three years. |
| 04.02 | Biennially or Every Two Years (B). The inspection effort should be performed every 2 years. |
| 04.03 | Annually (A). The inspection effort should be performed every year. Projects Branch Chief |
| 04.04 | Semiannually (S). The inspection effort should be performed two times each year. |
| 04.05 | Quarterly (Q). The inspection effort should be performed four times each year. |
| 04.06 | As Needed (AN). The inspection effort should be performed when the activity or event occurs at the facility as specified in the guidance section of specific inspection procedures (e.g, refueling outages). |
| 05.01 | Director, Office of Nuclear Reactor Regulation | |
| a. | Provides overall program direction for the reactor inspection program. | |
| b. | Develops and directs the implementation of policies, programs, and procedures for inspecting applicants, licensees, and other entities subject to NRC jurisdiction. | |
| c. | Assesses the effectiveness, uniformity, and completeness of implementa-tion of the reactor inspection program. | |
| 05.02 | Associate Director for Inspection and Programs. Directs the development of the inspection program within the Office of Nuclear Reactor Regulation (NRR). | |
| 05.03 | Director, Division of Inspection Program Management (DIPM). Manages inspection program development within NRR, develops and prepares revisions to the reactor inspection program, oversees regional implementation, and serves as the NRR contact with the regional offices for program development and implementation. | |
| 05.04 | Directors, Technical Divisions, NRR. Assists the Director, DIPM in developing the technical content of and reviewing periodic revisions to the requirements and guidance contained in inspection procedures related to their areas of technical expertise. | |
| 05.05 | Regional Administrator | |
| a. | Provides program direction for management and implementation of the inspection program elements performed by their regional office. | |
| b. | Ensures, within budget limitations, that the regional office staff includes adequate numbers of inspectors in the various disciplines necessary to carry out the inspection program described in this chapter, including that which may be needed for regional supplemental and reactive inspections. | |
| c. | Directs the implementation of the supplemental inspection program in accordance with the guidance in Appendix B of this document. | |
| d. | Applies inspection resources, as necessary, to deal with significant issues and problems at specific plants. | |
The fundamental building blocks that form the framework for the regulatory oversight process are seven cornerstones of safety; initiating events, mitigating systems, barrier integrity, emergency preparedness, occupational radiation safety, public radiation safety, and physical protection. These cornerstones have been grouped into three strategic areas: reactor safety, radiation safety, and safeguards. This framework is based on the principle that the agency's mission of assuring public health and safety is met when the agency has reasonable assurance that licensee's are meeting the objectives of the seven cornerstones of safety. The reactor inspection program is an integral part, along with performance indicators (PIs), assessment, and enforcement, of the reactor oversight process. Acceptable performance in the cornerstones, as measured by the PIs and the risk-informed baseline inspection program, is indicative of overall performance that provides for adequate protection of public health and safety.
Another principle of the framework is that there is a level of performance above which the NRC does not need to engage the licensee beyond some minimum level of oversight. Performance indicators reported by power reactor licensees and the NRC's inspection program provide the information used in determining licensee performance in the cornerstones of safety. The risk-informed baseline inspection program is designed to be the inspection oversight that provides indications of performance within areas of the cornerstones of safety that are not measured by the PIs or not adequately measured by PIs. The PI program reporting guidelines are in NEI 99-02, "Regulatory Assessment Performance Indicator Guideline," which is endorsed by the NRC.
The supplemental portion of the inspection program will provide more diagnostic inspections of identified problems and issues beyond the baseline. Supplemental inspections will be planned in response to issues that result in crossing an Action Matrix threshold. These changes to the inspection program are factored into the inspection program through the assessment process, as further discussed in Section 8.0, below.
The inspection program described in this manual chapter is comprised of the following three major program elements:
Overall, the inspection program emphasizes achieving a balanced look at a cross section of licensee activities important to plant safety, reliability, and risk. The baseline inspections constitute an appropriate level of inspection at plants whose overall performance remains in the licensee response band. Plants, whose performance is outside the licensee response band, will receive additional plant specific supplemental inspection based on their assessed performance in the cornerstones of safety. Additionally, Appendix D is provided for use by the resident inspectors in conducting routine activities that may assist them in identifying potentially risk significant activities.
The supplemental inspections, described in Appendix B, are only performed as a result of performance issues that are identified by either performance indicators (PIs), baseline inspections, or event analysis. The depth and breadth of specific supplemental inspections chosen for implementation will depend upon the risk characterization of the issues as shown in the Action Matrix of the reactor assessment program (IMC 0305, "Operating Reactor Assessment Program").
The need for additional inspections to address emergent generic safety issues, such as those that were performed for motor-operated valves and year 2000 issues, will be assessed on a case by case basis. The need for additional, ad hoc inspections will be assessed for major licensee evolutions such as independent spent fuel storage facilities or steam generator replacements.
In addition to the three elements, the inspection program also provides for the agency's response to operational events. The guidance for determining the level of response to an event is contained in NRC Management Directive 8.3, "Incident Investigation Program."
| 07.01 | Risk-Informed Baseline Inspections. The baseline
inspection program element, described in Appendix A, is to
be performed at all operating reactors. It requires
inspections of licensee performance in the seven
cornerstones of safety.
The baseline inspections provide sufficient examination of the plants and licensee activities to determine, along with performance indicators, whether licensees are meeting the objectives of all seven cornerstones, and to identify indications of performance problems to allow further engagement by the NRC before the objectives of the cornerstones are compromised. The inspection procedures included in the baseline inspection program are based on "inspectable areas" for the seven cornerstones of safety. The oversight framework identified key attributes for each cornerstone that need to be verified to have a reasonable assurance that the cornerstone objectives are met. Licensee performance within the key attributes are then measured by either a performance indicator, a risk-informed inspectable area, or a combination of both indicator and inspection. The baseline inspection procedures are organized by cornerstone and include the inspectable areas associated with the cornerstone. The baseline inspections are performance-based and risk-informed and emphasize the observation and evaluation of ongoing facility operations and supporting activities affecting the safety function of facility structures, systems, and components. Appendix D has been provided to assist the resident inspectors in conducting activities that may identify potentially risk significant activities. The baseline inspections are risk informed through (1) the inspectable areas, which are based on their risk importance in measuring a cornerstone objective; (2) the inspection frequency and sample size for each inspectable area, which are based on risk information; and (3) sample selection of activities and equipment to inspect in each inspectable area, which is based on risk insights that will be modified by plant-specific information, Appendix A contains a list of baseline inspection procedures and specifies the required frequency for their performance. The baseline inspection procedures must be completed at every plant at a prescribed interval. In certain cases, completion of some inspection requirements may be accomplished through other inspections. See 2515-07.04. |
Inspection requirements are the controlling factor in determining the amount of inspection effort necessary to complete the baseline inspections. Appendix A provides an estimate of the hours associated with each inspection procedure for overall resource planning only. | |
| 07.02 | Plant Specific Supplemental Inspections |
| The supplemental element of the inspection program is
designed to apply NRC inspection assets in an increasing
manner when performance issues are identified, either by
inspection findings evaluated using the significance
determination process (SDP) or when performance indicator
thresholds are exceeded. Accordingly, the NRC regional
office will assess the need for supplemental inspections
after identifying an inspection finding categorized as risk
significant (i.e., white, yellow, or red) with the SDP, or
when a performance indicator exceeds the licensee response
band threshold. The scope and breadth of these inspections
will be based upon the guidance provided in the assessment
program's Action Matrix and expanded upon in the
"Supplemental Inspection Selection Table" included in
Appendix B.
Depending on the risk significance and breadth of the identified performance issues, the supplemental inspections provide a graded response, which includes: oversight of the licensee's root cause evaluation of the issues; expansion of the baseline inspection sample or a focused team inspection (as necessary to evaluate extent of condition); or a broad scope, multi-disciplined team inspection, which would include inspection of multiple cornerstone areas and inspection of crosscutting issues. Any new issues identified during the supplemental inspections will be evaluated by the SDP. The need for additional NRC actions, including additional supplemental inspections, will be governed by the Action Matrix. A supplemental inspection will be performed for all white, yellow, or red issues (either PIs or inspection findings). The region may choose not to perform a supplemental inspection for white issues identified as part of a licensee's self assessment, although such exceptions are expected to be infrequent. In such instances, the region will still ensure that the issue is entered into the licensee's corrective action program and that an appropriate evaluation is performed. The licensee's evaluation for such an issue will be reviewed as part of baseline inspection procedure 71152, "Identification and Resolution of Problems." | |
| 07.03 | Generic Safety Issues, Special, and Infrequent Inspections.
Concerns with specific safety issues that arise may be
addressed solely through the NRR license review process
and the use of regulatory communications issued to
licensees. If the concern is of safety significance, it may be
appropriate to perform a one-time inspection under the
safety issues program element. These inspections will be
established by temporary instructions (TIs). For example,
when it is determined that a safety issue addressed in a
bulletin or generic letter requires inspection verification or
followup, requirements and guidance for the inspection will
be developed and issued in a TI. Unless such a TI is issued,
inspection followup is not required to verify completion of
licensees' actions discussed in a bulletin or generic letter.
When a TI is issued, overall assessment ratings may be
considered in establishing priorities for conducting these
inspections. The plants to be inspected will be designated
in the TIs.
The resources budgeted to safety issues inspections are established by NRR. It is the intent that the inspections be conducted within the resources budgeted for that element of the program. Specific criteria for closing a TI will be addressed in the TI itself. In general, TIs should not be closed until all relevant safety issue items have been completed by the licensee and verified by inspection. However, exceptions may be considered when the licensee's schedule for completing items remaining is acceptable, properly documented, and is not a critical element to resolving the safety issue. The need may arise for specific inspections to address major evolutions limited to a few licensees such as upgrading to a digital control system. The need for these inspections will also be assessed on a case-by-case basis and conducted under the guidance of a temporary instruction. This element of the inspection program also includes other special or infrequently performed inspections. These inspections may be in response to events, infrequent major activities at nuclear power plants, or to fulfil the NRC's obligations under interagency memoranda of understanding. The applicable procedures are listed in Appendix C, "Special and Infrequently Performed Inspections." |
| 07.04 | Related Activities Associated with the Reactor Inspection Program. All inspections, as well as performance indicators reported by licensees, provide input to the plant performance assessment process. The performance assessment process is to be conducted in accordance with IMC 0305, "Operating Reactor Assessment Program." |
| 08.01 | General. The inspection program described in Appendices
A, B, and C is intended to provide the framework for
managing inspection resources without being overly
prescriptive. At the same time, a level of inspections
necessary to complete pre-defined objectives at a facility is
specified, below which inspection should not decrease. It is
intended to place inspection emphasis on elements of
licensee activities most important to reactor safety, radiation
safety, and safeguards.
Using a performance-based, risk-informed approach, inspectors focus their attention on activities important to safety. Performance-based inspection emphasizes observing activities and the results of licensee programs over reviewing procedures or records. For example, an inspector may identify an issue through observing a plant activity in progress, monitoring equipment performance, or the in-plant results of an activity (e.g. an engineering calculation)--and then let the observed discrepancy or uncertainty lead to evaluation of other associated areas. Discussions with plant personnel and reviewing documents should be used to enhance or verify performance-based observations. These procedures are designed to emphasize observation of activities, or those portions that are most risk significant in terms of safety and reliability. It is expected that resident and region-based inspectors will have the necessary technical capability to accurately observe and evaluate the activity. NRC inspectors perform a basic mission in determining whether a licensee operates the plant safely and meets current regulatory requirements and commitments. Limiting inspection to identification of specific instances where a licensee fails to meet such requirements and commitments could result in correction of symptoms rather than correction of underlying causes of licensee problems. The inspection and assessment processes establish thresholds for determining the significance of issues and whether those issues may require additional evaluation and follow up. Thus, the inspection program requires that inspectors and their managers evaluate problems to determine if follow up inspections are necessary to diagnose whether a safety concern represents an isolated case or may signify a broader, more serious problem based on the evaluated significance of the issues. Licensee management controls (e.g., QA, safety committees, etc.) may need to be examined to determine if weaknesses in these controls contributed to identified safety concerns. |
| The NRC inspection program covers only small samples of licensee activities in any particular area. The sample sizes specified in the inspection procedures are based on the relative importance of the area covered by the procedure to the other areas inspected by the program. They are also based on the inspectors choosing a "smart" sample instead of a statistically based random sample because the risk-informed nature of the inspection program requires the inspections to be focused on those aspects of plant operations and licensee activities that could pose the greatest risk to public health and safety. The philosophy behind this concept is that the licensee's processes are effective if they deal properly with the items of greatest significance. Some areas (such as reviewing 10 CFR 50.59 evaluations) do not have a direct connection with risk and inspection sample sizes in these areas are chosen to provide periodic indications of a licensee's performance in those areas. | |
| 08.02 | Allocation of Resources as a Function of Performance
Assessment. The results of plant performance assessments
are an important factor in defining the inspection program
for each plant. The baseline inspections are the level of
defined requirements for all plants and additional regional
supplemental inspections will be planned for plants whose
performance is below a certain level, i.e., the licensee
response band. The amount and focus of the additional
supplemental inspections will be proportional to the plant's
assessed performance and the nature of the issues that
provide the indication of that performance. See IMC 0305,
"Operating Reactor Assessment Program," for more
detailed guidance on responding to issues with licensee
performance.
Only baseline inspections, applicable generic safety issues, and special and infrequent inspections will be planned and conducted at plants whose overall performance (all performance indicators and inspection findings) is determined to be in the licensee response band. Plants whose performance is determined to be outside of the licensee response band (see IMC 0305) should have supplemental inspections planned to examine the root causes of the change in performance and corrective actions of identified findings or safety issues that have indicated the performance change. |
| 08.03 | Allocation of Resources Among Program Elements. The allocation of resources among the three principal inspection program elements (baseline, supplemental, and generic safety issues) is provided for each year in the budget process. |
| 08.04 | Completion of Inspection Procedures. The baseline
inspection procedures represent the inspection necessary to
allow the NRC to assess performance. This means that the
inspector is to perform the requirements in each inspectable
area within the baseline inspection procedures unless
approval is given by the Director, Division of Inspection
Program Management, NRR. Likewise, each inspection
requirement contained in the supplemental inspection
procedures must be adequately addressed.
Inspection procedures identify requirements that the inspector must consider while evaluating the associated area. These requirements may not be the same as NRC requirements placed on a specific licensee. As such, it is not implied or intended that inspection program requirements are to be levied on the licensee. Any attempt to force inspection program requirements on the licensee constitutes misinterpretation of NRC inspection philosophy and misuse of inspection requirements. Temporary instructions are issued for specific inspection purposes. For inspections performed using a temporary instruction, the inspector is expected to complete all inspection requirements listed. |
| 08.05 | Program Feedback. The reactor inspection program is expected to be dynamic and to respond to changes in the nuclear power industry and operational experience. Therefore, the program office expects the regions and inspectors to identify problems in implementing the program, and to recommend changes to the program for consideration by the program office. Any such feedback and recommendations should be submitted to IIPB through the associated regional office. |
Regional offices must develop annual site-specific inspection plans consistent with the Inspection Planning (IP) module of the Reactor Program System (RPS) to help manage inspection resources and monitor the inspection programs. Under circumstances where the operation of multiple units at a site is not comparable (e.g., Millstone), the inspection plan should be specific for each unit. The regional integrated inspection plan (i.e., the integration of individual site or unit plans) should project the planned inspection activities and available resources for all sites for at least the next 12 months. The integrated plan should also provide for a summary of the fraction of regional resources allocated to each of the individual program elements discussed in section 2515-06 of this manual chapter for each site.
Planning significant alterations to the baseline inspection program for a plant's annual inspection plan to accommodate the plant's particular situation needs the concurrence of the Chief, Inspection Program Branch. Significant alterations include treating a multi-unit site as separate single unit sites, or increasing or decreasing the frequency of inspections or sample sizes from those stated in the baseline inspection procedures. The factors to consider when planning alterations to the baseline inspection program at a plant site include (1) known plant activities (or lack thereof), (2) the plant's size, design, and age, and (3) complexity of the licensee's programs.
The results of the end-of-cycle and mid-cycle performance reviews, conducted in accordance with IMC 0305, shall be used to schedule baseline inspections and to determine the amount and focus of planned supplemental inspections at each site. The basis for the allocation or significant reallocation of resources among the sites will be documented. It is expected that the integrated plans will be living documents and be reviewed periodically, adjusted, and reissued to reflect shifts in plant performance and safety concerns. Individual site plans and the regional integrated inspection plan should be reviewed by regional management and updated at least semiannually as part of the assessment process that is discussed in IMC 0305.
As a general rule, inspections should be conducted in accordance with inspection procedures. However, it is not possible to anticipate all the unique circumstances that might be encountered during the course of a particular inspection and, therefore, individual inspectors are expected to exercise initiative in conducting inspections, based on their expertise and experience and risk insights, as needed to assure that all the inspection objectives are met.
| 11.01 | Resident Inspector Policy. The resident inspectors provide
the major onsite NRC presence for direct observation and
verification of licensees' ongoing activities. Appendix D
outlines the responsibilities of resident inspectors for being
aware of major activities and the current status of the plant
as NRC's onsite representative. The resident inspectors
also are primary NRC onsite evaluators for events or
incidents. See section 11.3, "Responding to Events and
Event Reports," below. The greater part of initial
event-related inspection effort will be performed by the
resident inspectors, who may be augmented by other
inspectors depending on the type and significance of the
event. Regional managers will decide when normal
inspection activities will be resumed by those involved with
inspecting events.
The following is the general policy on the extent to which resident inspectors are to provide coverage at all sites with one or more units licensed for operation. |
| 11.02 | Regional Inspector Policy. Regional inspectors conduct inspections as directed by their supervisors. In addition to baseline inspection program procedures, regional inspectors often will conduct inspections under other program elements described in this chapter. Certain aspects of their inspection activity may be conducted in the regional office; e.g., portions of procedure review and administrative program inspection. |
| 11.03 | Inspection Coordination. The senior resident inspector and
the regional Division of Reactor Projects must be kept
advised of regional and headquarters inspectors' activities
at the facility. The associated regional branch chief must
ensure coordination of regional and headquarters inspection
activities in accordance with IMC 0301, "Coordination of
NRC Visits to Commercial Reactor Sites."
Regional and headquarters-based inspectors should contact the senior resident inspector before each inspection to get information concerning the availability of specific licensee personnel and the status of plant conditions that may affect the planned inspection. In addition, they should contact the senior resident inspector as soon as is convenient after they arrive at the site to ensure a coordinated NRC presence at the facility. The visiting inspectors should advise the senior resident inspector of changes to their planned inspection effort and schedule for the exit interview with the licensee. The senior resident inspector should inform the regional and headquarters inspectors of any unique activities in progress and offer specific inspection suggestions. The regional and headquarters inspectors should brief the senior resident inspector about the results of their inspection before the exit meeting with the licensee's management. The senior resident inspector (or resident inspector in his absence) should attend all exit meetings where significant issues are expected to be discussed. |
| 11.04 | Third Party Assistance. On occasion licensees ask inspectors for recommendations for obtaining help solving programmatic problems. Inspectors are prohibited from recommending the services of individuals or organizations for a project under NRC regulatory jurisdiction. Providing such a recommendation violates 5 C.F.R. 2635.702, which prohibits Federal employees from using public office for endorsement of any product, service, or enterprise. For further information refer to the Executive Director for Operations' (EDO's) Field Policy Manual No. 19, "Guidance For Recommending Third Party Assistance to Licensees," which can found at the following Internet Web address: (http://www.internal.nrc.gov/NRC/NUREGS/BR0075/R4/index.html). |
2515-12 General Inspection Policies
| 12.01 | Management Entrance and Exit Meetings. Inspectors are
required to meet with licensee management as part of every
inspection. Region-based inspectors should hold an
entrance meeting with the senior licensee representative
who has responsibility for the areas to be inspected. Each
inspection conducted by resident inspectors and
region-based inspectors must include discussing inspection
results with licensee management. At the conclusion of an
inspection, inspectors must discuss their preliminary
findings with the licensee's management at a scheduled exit
meeting. Management and exit meetings with licensee
personnel should be scheduled to have the minimum impact
on other licensee activities necessary to assure the safe
operation of the plant.
Time spent on scheduled and periodic entrance and exit meetings (including preparing for the meetings) is considered part of preparation and documentation of inspections. Entrance meeting time is charged to preparation and exit meeting time is charged to documentation. Daily communications with licensee management is considered to be an integral part of every inspection procedure and the time used for such routine communications should be charged to the inspection procedures used. Communicating inspection observations also is an integral and important part of every inspection, whether done daily during the course of an inspection, or periodically with status meetings. Many licensees have expressed the desire to hear inspector insights related to safety/regulatory performance even in instances where they do not reach the threshold for documentation in an inspection report (see IMC 0610*, "Reactor Inspection Reports"). When deciding which observations and insights to pass on to the licensee, inspectors should consider the following: |
| |
| 12.02 | Review of Updated Final Safety Analysis Report (UFSAR) |
| For planning inspections, several baseline inspection
procedures specify reviewing applicable portions of the
plant's UFSAR. This review is intended to provide the
inspectors with design bases insights in preparing for
inspections and is not intended to be a review of UFSAR
accuracy. The general focus of the baseline inspection
program is to monitor licensee performance, therefore
UFSAR accuracy will not be routinely inspected, although
it is a source of information for inspections.
However, the NRC does rely on the accuracy of the UFSAR in making informed licensing decisions on changes; therefore limited requirements for UFSAR accuracy may be incorporated into specific inspection procedures. Perform these inspection requirements as directed by the implementing procedure. | |
| 12.03 | Responding to Events and Event Reports. Routine events
of low significance, such as uncomplicated reactor trips,
will be followed up by resident or region-based inspectors
to verify that the events are not complicated by loss of
mitigation equipment or other factors. This event follow up
is part of the baseline inspection program, and emphasizes
collecting information about the event for use by risk
analysts in evaluating the risk significance of the event to
help regional and headquarters management determine if a
response beyond the baseline program is warranted.
The significance of operational events is evaluated using the Conditional Core Damage Probability (CCDP) metric, which best reflects the full extent of any loss of defense-in-depth due to the event, in conjunction with various deterministic criteria to address the most influential related assumptions and uncertainties. The significance is determined regardless of whether the cause is due to licensee performance or otherwise. The agency's response to significant events is described in NRC Management Directive 8.3, "NRC Incident Response Program." In general, significant operational events may be investigated by multi-disciplined Incident Investigation Teams (IITs) that are initiated by the EDO, and are comprised of both regional and headquarters personnel. Operational events of lesser significance may be investigated by Augmented Inspection Teams (AITs) that are initiated by Regional Administrators. Regional Administrators may also initiate special inspection (SI) teams that use only regional personnel. The applicable procedures for AITs and SI teams are listed in Appendix C, "Special and Infrequently Performed Inspections." In addition, for an event of extraordinary safety significance or profound regulatory implications, an Accident Review Group may be formed that reports directly to the Commission, as described in Management Directive 8.9, "Accident Investigation." |
Licensees often notify inspectors of events or conditions in anticipation of the inspectors' interest in the issue, but such notifications do not exempt the licensee from reporting events and conditions through the required regulatory processes. The licensee should be made aware that documents that it gives to inspectors are subject to Freedom of Information Act requests and may be placed in the Public Document Room. In addition to reviewing plant events to determine whether the NRC should devote additional effort and resources to respond to the event, the baseline inspection program screens for potential risk significance and possible future inspection all written event reports submitted to the NRC by licensees. The review should be acknowledged in an inspection report. | |
| 12.04 | Findings Outside of Inspector's Qualifications. Inspectors
sometimes identify issues or violations outside of the
inspector's qualifications or expertise. In these cases the
inspector is responsible for (1) determining if an immediate
threat to public or worker health or safety exists, and if one
does exist to notify licensee management immediately,
(2) determining if the issue is better addressed by an
inspector with different qualifications (i.e., a specialist
inspector). Inspectors may follow issues outside of their
qualifications or expertise with the concurrence of a
regional manager responsible for the area associated with
the issue and the inspector's supervisor.
Such issues are associated with the most applicable cornerstone and inspectable area, regardless of the baseline inspection procedure in use when the issue is identified. The inspector's time associated with the issue is charged to the baseline procedure that best corresponds to the issue. If the issue is found during inspections other than baseline inspections, the time is charged to the procedure in use. |
| END |
Appendices:
A. Risk-Informed Baseline Inspection Program
B. Supplemental Inspection Program
C. Generic, Special, and Infrequent Inspections
D. Plant Status
END