Power Reactor Status Report for June 28, 2008
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Beaver Valley 1 | 100 | ||||
Beaver Valley 2 | 100 | ||||
Calvert Cliffs 1 | 100 | ||||
Calvert Cliffs 2 | 100 | ||||
FitzPatrick | 100 | * | |||
Ginna | 100 | ||||
Hope Creek 1 | 97 | 100% ELECTRICAL CAPABILITY | |||
Indian Point 2 | 100 | ||||
Indian Point 3 | 100 | ||||
Limerick 1 | 100 | ||||
Limerick 2 | 100 | ||||
Millstone 2 | 100 | ||||
Millstone 3 | 100 | ||||
Nine Mile Point 1 | 100 | ||||
Nine Mile Point 2 | 100 | ||||
Oyster Creek | 100 | ||||
Peach Bottom 2 | 100 | ||||
Peach Bottom 3 | 100 | ||||
Pilgrim 1 | 100 | 345 KV LINE 322 OOS | |||
Salem 1 | 100 | ||||
Salem 2 | 98 | GOVERNOR VALVES WIDE OPEN | |||
Seabrook 1 | 100 | ||||
Susquehanna 1 | 94 | NEW NSSS LIMIT DUE TO POWER UPRATE | * | ||
Susquehanna 2 | 100 | * | |||
Three Mile Island 1 | 100 | * | |||
Vermont Yankee | 100 |
Region 2
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Browns Ferry 1 | 100 | ||||
Browns Ferry 2 | 92 | REDUCED FOR CONTROL VALVE TESTING | * | ||
Browns Ferry 3 | 100 | ||||
Brunswick 1 | 100 | ||||
Brunswick 2 | 100 | ||||
Catawba 1 | 100 | ||||
Catawba 2 | 100 | ||||
Crystal River 3 | 100 | ||||
Farley 1 | 100 | ||||
Farley 2 | 100 | ||||
Harris 1 | 100 | ||||
Hatch 1 | 83 | REDUCED FOR ROD PATTERN ADJUSTMENT | * | ||
Hatch 2 | 100 | ||||
McGuire 1 | 0 | 06/26/2008 | TRIPPED. SEE EN #44318. | ||
McGuire 2 | 100 | ||||
North Anna 1 | 100 | HOT WEATHER ALERT | |||
North Anna 2 | 100 | HOT WEATHER ALERT | |||
Oconee 1 | 100 | ||||
Oconee 2 | 100 | ||||
Oconee 3 | 100 | ||||
Robinson 2 | 100 | ||||
Saint Lucie 1 | 100 | ||||
Saint Lucie 2 | 100 | ||||
Sequoyah 1 | 100 | ||||
Sequoyah 2 | 100 | ||||
Summer | 100 | ||||
Surry 1 | 100 | * | |||
Surry 2 | 100 | * | |||
Turkey Point 3 | 2 | POWER REDUCED TO CONDUCT TURBINE BALANCING | * | ||
Turkey Point 4 | 100 | ||||
Vogtle 1 | 100 | ||||
Vogtle 2 | 98 | 100% ELECTRICAL CAPABILITY | |||
Watts Bar 1 | 100 |
Region 3
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Braidwood 1 | 100 | ||||
Braidwood 2 | 100 | ||||
Byron 1 | 100 | ||||
Byron 2 | 100 | ||||
Clinton | 97 | 100% ELECTRICAL CAPABILITY | |||
D.C. Cook 1 | 90 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
D.C. Cook 2 | 100 | ||||
Davis-Besse | 100 | ||||
Dresden 2 | 99 | 100% ELECTRICAL CAPABILITY | |||
Dresden 3 | 99 | 100% ELECTRICAL CAPABILITY | |||
Duane Arnold | 96 | 98% ELECTRICAL CAPABILITY - DERATE | |||
Fermi 2 | 100 | ||||
Kewaunee | 98 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
La Salle 1 | 100 | ||||
La Salle 2 | 100 | ||||
Monticello | 100 | ||||
Palisades | 100 | ||||
Perry 1 | 64 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
Point Beach 1 | 98 | AFW TESTING IN PROGRESS | * | ||
Point Beach 2 | 98 | AFW TESTING IN PROGRESS | |||
Prairie Island 1 | 99 | POWER REDUCED DUE TO CALORIMETRIC MONITORING ISSUE | |||
Prairie Island 2 | 100 | ||||
Quad Cities 1 | 99 | 100% ELECTRICAL CAPABILITY | * | ||
Quad Cities 2 | 97 | 100% ELECTRICAL CAPABILITY |
Region 4
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Arkansas Nuclear 1 | 100 | ||||
Arkansas Nuclear 2 | 100 | ||||
Callaway | 100 | ||||
Columbia Generating Station | 85 | ECONOMIC DISPATCH | |||
Comanche Peak 1 | 100 | ||||
Comanche Peak 2 | 100 | ||||
Cooper | 100 | ||||
Diablo Canyon 1 | 100 | ||||
Diablo Canyon 2 | 100 | ||||
Fort Calhoun | 98 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
Grand Gulf 1 | 100 | ||||
Palo Verde 1 | 100 | * | |||
Palo Verde 2 | 100 | ||||
Palo Verde 3 | 100 | ||||
River Bend 1 | 45 | INCREASING POWER | * | ||
San Onofre 2 | 97 | STEAM GENERATOR PRESSURE LIMITATIONS | |||
San Onofre 3 | 96 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
South Texas 1 | 100 | ||||
South Texas 2 | 100 | ||||
Waterford 3 | 100 | ||||
Wolf Creek 1 | 100 |