Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Power Reactor Status Report for March 18, 2008

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100     *  
Ginna 100        
Hope Creek 1 100   OFFSITE LINE 5023 (500 KV) OOS    
Indian Point 2 98   COASTDOWN TO REFUELING OUTAGE LINE 13W93 OOS *  
Indian Point 3 100   LINE 13W93 OOS *  
Limerick 1 0 02/29/2008 REFUELING OUTAGE *  
Limerick 2 100        
Millstone 2 100        
Millstone 3 100   LINE 348 (345 KV) OOS UNTIL 3/21    
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 93   HOLDING POWER FOR CONTROL VALVE OSCILLATION PROBLEM AND FEEDWATER HEATER ISSUES *  
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 0 03/11/2008 REFUELING OUTAGE DEFUELED *  
Seabrook 1 100   369 KV NEWINGTON LINE OOS FROM 1300-1500 *  
Susquehanna 1 0 03/03/2008 REFUELING OUTAGE    
Susquehanna 2 100   VOLTAGE REGULATOR IN MANUAL    
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 31   COMMENCE REFUELING OUTAGE AT 0900 *  
Brunswick 1 0 03/14/2008 REFUELING OUTAGE *  
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Crystal River 3 0 03/01/2008 DROP LINE WELD REPAIR IN PROGRESS    
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 0 03/14/2008 MAINTENANCE OUTAGE    
Hatch 2 100        
McGuire 1 100        
McGuire 2 0 03/01/2008 DEFUELED    
North Anna 1 100        
North Anna 2 100        
Oconee 1 73   1A1 RCP SHUT DOWN    
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100   161 KV MOCCASIN LINE OOS THRU 3/21    
Sequoyah 2 100   161 KV MOCCASIN LINE OOS THRU 3/21    
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 0 03/15/2008 REFUELING OUTAGE *  
Vogtle 2 99   100% ELECTRICAL CAPABILITY *  
Watts Bar 1 0 02/10/2008 REFUELING OUTAGE    

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 96   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 99   100% ELECTRICAL CAPABILITY; LINE 1221 (345KV) OOS WITH SWITCHING ONGOING UNTIL 3/18 *  
Dresden 3 98   100% ELECTRICAL CAPABILITY    
Duane Arnold 98   100% ELECTRICAL CAPABILITY *  
Fermi 2 100   SHOAL LINE (120KV) OOS UNTIL 3/20 (1 OF 5) *  
Kewaunee 100        
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 60   POWER SUPPRESSION TESTING AND ROD SEQUENCE EXCHANGE *  
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 0 03/16/2008 REFUELING OUTAGE    
Prairie Island 2 100        
Quad Cities 1 97   100% ELECTRICAL OUTPUT    
Quad Cities 2 0 03/02/2008 REFUELING OUTAGE    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 0 03/16/2008 REFUELING OUTAGE    
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 45   INCREASING POWER *  
Cooper 90   COASTDOWN TO REFUELING OUTAGE    
Diablo Canyon 1 100   DIABLO-MESA 230 KV LINE OOS 3/11 THRU 3/18. DIABLO-GATES1 500 KV LINE OOS THRU 3/28    
Diablo Canyon 2 0 02/03/2008 DEFUELED    
Fort Calhoun 0 03/15/2008 TRIP SEE EN# 44066    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 70   TROUBLESHOOT FEEDWATER HEATER FLOW ISSUE *  
San Onofre 2 99        
San Onofre 3 100        
South Texas 1 89   COASTDOWN TO REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 0 03/17/2008 TRIP - SEE EN #44072 *  

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021