Part 21 Report - 1996-550

LICENSEE: ROCHESTER GAS & ELECTRIC CORP. SITE: GINNA 1 EN NUMBER:31128 DOCKET: 05000244 EVENT DATE: 10-10-96 RX TYPE: PWR EVENT TIME: 09:38 VENDORS: W-2-LP NOTIFY DATE: 10-10-96 EMERGENCY CLASS: N/A REGION: 1 STATE: NY TIME: 09:38 OPS OFFICER: JOHN MacKINNON 10 CFR SECTION: CCCC 21.21 UNSPECIFIED PARAGRAPH UNIT SCRAM RX INIT INITIAL MODE CURR CURRENT MODE CODE CRIT PWR PWR 1 N Y 100 POWER OPERATION 100 POWER OPERATION "A" SERVICE WATER PUMP MOTOR DID NOT PASS ITS POST-MODIFICATION FUNCTIONAL TEST. A 350HP, 1800RPM, 460VAC, 3 PHASE, 500G FRAME, 1.15 SF, VERTICAL HOLLOW SHAFT MOTOR FOR USED AS A SERVICE WATER (SW) PUMP MOTOR MANUFACTURED BY U.S ELECTRICAL MOTORS DID NOT PASS ITS POST-MODIFICATION FUNCTIONAL TESTING PROGRAM. THE MOTOR WAS REMOVED FROM THE "A' SW PUMP, DISASSEMBLED, AND INSPECTED. INFERIOR WORKMANSHIP WAS DISCOVERED, MOST NOTABLY, DAMAGED MOTOR LEADS. IN THE SCENARIO OF THE "C" SW PUMP OUT OF SERVICE AND A CONCURRENT LOSS OF POWER TO BUS 17, A LOSS OF ALL SW WOULD OCCUR IF THE "A" SW PUMP FAILED TO OPERATE DUE TO THE IDENTIFIED DEFECT. THIS MOTOR WAS PURCHASED COMMERCIAL-GRADE, WAS COMMERCIALLY-DEDICATED BY ROCHESTER GAS & ELECTRIC, AND SATISFIED ALL TESTING REQUIREMENTS INCLUDED IN THE PROCUREMENT DOCUMENTS.