Part 21 Report - 1996-236
ACCESSION #: 9606040240 Information & Support Services P.O. Box 3707 Seattle, WA 98124-2207 May 30, 1996 G-1151-SJA-96-302 Document Control Desk United States Nuclear Regulatory Commission Washington, D. C. 20555 BOEING Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Tenera Engineering Services Gibbs & Hill, Inc. Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator G-1151 M/S 7A-33 (206) 865-6248 Attachment(s): GTSTRUDL Program Report Form No. 96.16 Georgia Tech Computer Aided Structural Engineering Center Georgia Institute of Technology School of Civil & Environmental Engineering Atlanta, Georgia 30332-0355 USA 404-894-2260 404 894 8014 FAX May 24, 1996 Attention: Nuclear Administrator Boeing Information & Support Services P.O. Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM No. 96.16 and a VENDOR ACKNOWLEDGEMENT FORM. Please sign and return the VENDOR ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards, CASE Center Catherine Lee Configuration Control Manager CL/jhb Enclosures An Equal Education and Employment A Unit of the University System Opportunity Institution of Georgia GTSTRUDL Program Report Form GPRF No.: 96.16 DATE: May 23, 1996 FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. _ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. _ MINOR Problem can be worked around or problem poses high frustration factor. _ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed May 23, 1996 Date Notification Sent May 24, 1996 Computers All Operating System All Version 94.01 and later Target Release for Correction 96.02 Mgr. ASD Signature Title R & D Division Michael H. Swanger Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 96.16 DATE: May 23 1996 DESCRIPTION: The LIST DYNAMIC PARTICIPATION FACTORS command produces incorrect results for the case when rotated released support conditions are present in a consistent mass model. A consistent mass model will be computed if the INERTIA OF JOINTS CONSISTENT command is given or if rigid body elements are used in the model. The only possible work around at this time is to avoid one or more of these conditions. Other dynamic analysis computations or results are not adversely affected by these conditions. Applicable sections of the User's Manual Inertia specification Command Section 2.4.3.1, Vol. 3 The JOINT RELEASES Command Section 2.1.7.2, Vol. 1 Joint Constraints Section 5.9, GTSTRUDL Release Guide Version 9401 RS, 9401VAX, 9401 Solaris Section 6.9, GTSTRUDL Release Guide Version 9401 PC, 9601 PC Rev. 2.2 *** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021