Part 21 Report - 1996-202
ACCESSION #: 9512200024 Information & Support Services P.O. Box 3707 Seattle, WA 98124-2207 BOEING December 12, 1995 G-1151-SJA-95-519 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992 R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Tenera Engineering Services Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator G-1151 M/S 7A-33 (206) 865-6248 Attachment(s): GTSTRUDL Program Report Form No. 95.28 Georgia Tech GT STRUDL December 5, 1995 Attention: Nuclear Administrator Boeing Information & Support Services P.O.Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM No. 95.28 and a VENDOR ACKNOWLEDGEMENT FORM. Please sign and return the VENDOR ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards, CASE Center Catherine Lee Configuration Control Manager CL/jhb Enclosures School of Civil & Environmental Computer Aided Structural Engineering Engineering Center Georgia Institute of Technology Phone: (404) 894-2260 Atlanta, Georgia 30332-0355 USA Fax: (404) 894-8014 A Unit of the University System of Georgia GTSTRUDL Program Report Form GPRF No.: 95.28 DATE: December 5, 1995 FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. MINOR Problem can be worked around or problem poses high frustration factor. INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed December 5, 1995 Date Notification Sent December 7, 1995 Computers ALL Operating System ALL Version 9101 thru 9401 Target Release for Correction 9601 Director, R&D Signature Title R & D Division Kenneth Will December 5, 1995 Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 95.28 DATE: December 5, 1995 DESCRIPTION: In GTModeler, if a user specifies the Density in force units other than pounds or the Coefficient of Thermal Expansion (CTE) in temperature units other than degrees Fahrenheit, incorrect data will be stored. If the data is specified in GTSTRUDL command mode and subsequently output in GTModeler, it will appear that the data is incorrect. However, the data is still stored correctly and will be used correctly after returning to GTSTRUDL. Users may verify the values that will be used in an analysis by issuing the PRINT MEMBER CONSTANTS command. Workaround: in GTModeler, specify the Density only in force units of pounds and CTE only in degrees Fahrenheit. Alternatively, the user may specify the data and assign it to members in the command mode of GTSTRUDL. Applicable Sections of the Users Manual Documentation: CONSTANTS command: Section 2.1.10.2 of Volume 1 MATERIAL command: Section 2.1.10.3 of Volume 1 PRINT MEMBER CONSTANTS command: Section 2.1.14.2 of Volume 1 GEN PROP, MATL in GTModeler: Section 9.1 of Volume 6 EDIT PROP, MATL in GTModeler: Section 13.3.1 of Volume 6 Rev. 2.2 *** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021