Skip to main content

Event Notification Report for August 28, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/27/2025 - 08/28/2025

EVENT NUMBERS
578915789257889
Agreement State
Event Number: 57891
Rep Org: New York State Dept. of Health
Licensee: Gentech Scientific, LLC
Region: 1
City: Arcade   State: NY
County:
License #: C5661
Agreement: Y
Docket:
NRC Notified By: Nathaniel Kishbaugh
HQ OPS Officer: Ian Howard
Notification Date: 08/29/2025
Notification Time: 12:46 [ET]
Event Date: 08/28/2025
Event Time: 00:00 [EDT]
Last Update Date: 08/29/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Carfang, Erin (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - LEAKING SOURCE

The following information was provided by the New York State Department of Health (NYSDOH) Bureau of Environmental Radiation Protection (BERP) via email:

"NYSDOH BERP received a phone call from the U.S. Nuclear Regulatory Commission (U.S. NRC) on August 29, 2025, at approximately 1045 EDT to report a call they received from Gentech Scientific, LLC, a NYSDOH radioactive material licensee, to report a leaking electron capture device (ECD) source. NYSDOH contacted Gentech Scientific, LLC on August 29, 2025, at approximately 1100 to follow up on this event. The representative from Gentech Scientific confirmed that a leak test was performed and analyzed by the National Leak Test Center (NYSDOH radioactive material license number C2323) the day prior (August 28, 2025) on entrance port, housing, and exit ports of an Agilent 58-90 ECD (serial number K3818) containing 15 millicuries of Ni-63 (foil source).

"Only the entrance port sample returned a result considered leaking in accordance with 10 CFR 31.5(c)(5) at 6789 pCi. The housing and exit port samples did not exceed this threshold.

"Following Gentech Scientific, LLC's awareness of this event, the affected device/source was carefully placed into isolation/quarantine in laboratory storage area, posted with signage, and licensee staff were informed on this event and instructed to keep away from this device. This leaking source did not result in the contamination of equipment, personnel, or surfaces.

"Gentech Scientific, LLC has notified Agilent of this leaking source and will be seeking options to return this device to Agilent or otherwise dispose of the source via transfer to a licensed waste broker. Leak test copies have been provided to NYSDOH.

"NYSDOH BERP is actively monitoring this event under Incident No. 1542. Additional information will be provided to NMED once available."


Agreement State
Event Number: 57892
Rep Org: New Mexico Rad Control Program
Licensee: Kaseman Presbyterian Hospital
Region: 4
City: Albuquerque   State: NM
County:
License #: MI-114-4
Agreement: Y
Docket:
NRC Notified By: Robert Bicknell
HQ OPS Officer: Ian Howard
Notification Date: 08/29/2025
Notification Time: 13:35 [ET]
Event Date: 08/28/2025
Event Time: 00:00 [MDT]
Last Update Date: 08/29/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following information was provided by the New Mexico Environment Department Radiation Control Bureau via email:

"One of our licensees Kaseman Presbyterian Hospital reported a medical event of a patient being administered 5 mCi of Ga-68 dotatate rather than Ga-68 PSMA [prostate-specific membrane antigen] on 8/28/2025, in Albuquerque New Mexico, license number MI-114-4. Written report is expected in 15 days. Further details will be provided as they become available."

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Non-Agreement State
Event Number: 57889
Rep Org: Weyerhaeuser
Licensee: Weyerhaeuser
Region: 4
City: Columbia Falls   State: MT
County:
License #: 25-15644-01
Agreement: N
Docket:
NRC Notified By: Hunter Kent
HQ OPS Officer: Sam Colvard
Notification Date: 08/28/2025
Notification Time: 17:40 [ET]
Event Date: 08/28/2025
Event Time: 09:48 [MDT]
Last Update Date: 08/28/2025
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
STUCK OPEN SHUTTER

The following is a summary of information provided by the licensee via phone:

On August 28, 2025, an authorized user notified the radiation safety officer that the shutter of a fixed Ohmart/Vega SHF1A source holder with a 50 mCi Cs-137 source could not be closed while preparing for a routine inspection of a process vessel. The entrance to the process vessel was barricaded. A do-not-operate tag was placed on the source holder shutter handle. Communication of the event to facility personnel is in progress. The manufacturer stated that the model of source holder is no longer in production and must be replaced. There were no overexposures due to this event.