Event Notification Report for June 09, 2025
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/08/2025 - 06/09/2025
Agreement State
Event Number: 57780
Rep Org: Kansas Dept of Health & Environment
Licensee: BHC Inc
Region: 4
City: Wyandotte State: KS
County:
License #: 22-B1053
Agreement: Y
Docket:
NRC Notified By: Aaron Short
HQ OPS Officer: Adam Koziol
Licensee: BHC Inc
Region: 4
City: Wyandotte State: KS
County:
License #: 22-B1053
Agreement: Y
Docket:
NRC Notified By: Aaron Short
HQ OPS Officer: Adam Koziol
Notification Date: 06/24/2025
Notification Time: 12:01 [ET]
Event Date: 06/09/2025
Event Time: 03:10 [CDT]
Last Update Date: 06/24/2025
Notification Time: 12:01 [ET]
Event Date: 06/09/2025
Event Time: 03:10 [CDT]
Last Update Date: 06/24/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Bywater, Russell (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Bywater, Russell (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
AGREEMENT STATE REPORT - STOLEN GAUGE
The following is a summary of information provided by the Kansas Department of Health and Environment (KDHE) via email:
On June 9, 2025, at 0310 CDT, licensee employees discovered that a work trailer had been forcibly entered, and several items stolen including a moisture density gauge. The gauge, a Humboldt 5001 EZ (serial number 10103) containing 11 mCi of Cs-137 and 44 mCi of Am-241/Be, had last been verified onsite on June 6, 2025, around 1730. The theft was reported to KDHE and Kansas City Police Department.
Kansas Event Number: KS250005
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of information provided by the Kansas Department of Health and Environment (KDHE) via email:
On June 9, 2025, at 0310 CDT, licensee employees discovered that a work trailer had been forcibly entered, and several items stolen including a moisture density gauge. The gauge, a Humboldt 5001 EZ (serial number 10103) containing 11 mCi of Cs-137 and 44 mCi of Am-241/Be, had last been verified onsite on June 6, 2025, around 1730. The theft was reported to KDHE and Kansas City Police Department.
Kansas Event Number: KS250005
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 57750
Rep Org: Colorado Dept of Health
Licensee: Consolidated Electrical Distributor
Region: 4
City: Denver State: CO
County:
License #: GL002424
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Ian Howard
Licensee: Consolidated Electrical Distributor
Region: 4
City: Denver State: CO
County:
License #: GL002424
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Ian Howard
Notification Date: 06/10/2025
Notification Time: 09:16 [ET]
Event Date: 06/09/2025
Event Time: 00:00 [MDT]
Last Update Date: 06/10/2025
Notification Time: 09:16 [ET]
Event Date: 06/09/2025
Event Time: 00:00 [MDT]
Last Update Date: 06/10/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGN
The following is a summary of information provided by the Colorado Department of Health (the Department) via email:
The Department received a notification from Consolidated Electrical Distributors that one exit sign with 10 Ci of H-3 was lost in Denver, CO. The exit sign is an Isolite Corporation Exit Sign, Model #: SLX60.
Colorado Event Report ID Number: CO250017
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of information provided by the Colorado Department of Health (the Department) via email:
The Department received a notification from Consolidated Electrical Distributors that one exit sign with 10 Ci of H-3 was lost in Denver, CO. The exit sign is an Isolite Corporation Exit Sign, Model #: SLX60.
Colorado Event Report ID Number: CO250017
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 57758
Rep Org: California Radiation Control Prgm
Licensee: Univ. of California, Los Angeles
Region: 4
City: Santa Monica State: CA
County:
License #: 1335-19
Agreement: Y
Docket:
NRC Notified By: Robert Greger
HQ OPS Officer: Kerby Scales
Licensee: Univ. of California, Los Angeles
Region: 4
City: Santa Monica State: CA
County:
License #: 1335-19
Agreement: Y
Docket:
NRC Notified By: Robert Greger
HQ OPS Officer: Kerby Scales
Notification Date: 06/11/2025
Notification Time: 19:35 [ET]
Event Date: 06/09/2025
Event Time: 00:00 [PDT]
Last Update Date: 06/11/2025
Notification Time: 19:35 [ET]
Event Date: 06/09/2025
Event Time: 00:00 [PDT]
Last Update Date: 06/11/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following information was received from the California Department of Public Health via email:
"University of California, Los Angeles (UCLA) Health reported that a patient being treated for liver cancer underwent a Y-90 brachytherapy microsphere treatment on June 9, 2025. The written directive by the authorized user called for 120 Gy each [to be administered] to both the middle section (a 3 GBq vial) and the right liver section (a 20 Gbq vial). Post therapy evaluations determined that the administered dose to the right section of the liver was 88.9 Gy (74.08 percent of the prescribed dose), which is an underdose of more than 20 percent. The administered dose to the middle section of the liver was 114.2 Gy (95.17 percent of the prescribed dose) and was in accordance with the written directive. UCLA Health is conducting an investigation and will submit a 15-day report to the California Radiation Health Branch.
California 5010 Number: 060925
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was received from the California Department of Public Health via email:
"University of California, Los Angeles (UCLA) Health reported that a patient being treated for liver cancer underwent a Y-90 brachytherapy microsphere treatment on June 9, 2025. The written directive by the authorized user called for 120 Gy each [to be administered] to both the middle section (a 3 GBq vial) and the right liver section (a 20 Gbq vial). Post therapy evaluations determined that the administered dose to the right section of the liver was 88.9 Gy (74.08 percent of the prescribed dose), which is an underdose of more than 20 percent. The administered dose to the middle section of the liver was 114.2 Gy (95.17 percent of the prescribed dose) and was in accordance with the written directive. UCLA Health is conducting an investigation and will submit a 15-day report to the California Radiation Health Branch.
California 5010 Number: 060925