Event Notification Report for February 24, 2025
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
02/23/2025 - 02/24/2025
EVENT NUMBERS
57570
57570
Agreement State
Event Number: 57570
Rep Org: Tennessee Div of Rad Health
Licensee: World Testing Inc.
Region: 1
City: Cumberland City State: TN
County:
License #: R-95009
Agreement: Y
Docket:
NRC Notified By: Andrew Holcomb
HQ OPS Officer: Brian P. Smith
Licensee: World Testing Inc.
Region: 1
City: Cumberland City State: TN
County:
License #: R-95009
Agreement: Y
Docket:
NRC Notified By: Andrew Holcomb
HQ OPS Officer: Brian P. Smith
Notification Date: 02/25/2025
Notification Time: 12:12 [ET]
Event Date: 02/24/2025
Event Time: 00:00 [EST]
Last Update Date: 02/25/2025
Notification Time: 12:12 [ET]
Event Date: 02/24/2025
Event Time: 00:00 [EST]
Last Update Date: 02/25/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - DAMAGED RADIOGRAPHY CAMERA
The following report was received via email by the Tennessee Division of Radiation Health:
"During a scheduled work visit to the TVA Cumberland City facility, a radiography crew was descending an outside set of stairs covered with ice. The worker slipped on the stairs and released the camera which dropped approximately 20 feet to the ground. The team surveyed the area to ensure it was safe to approach the device. After ensuring the device was secured, it was placed into an overpack and transferred back to the licensee's facility. A minor amount of damage was incurred to the rear of the device. The team had no indication that the source was compromised.
Manufacturer: QSA Global
Model: Sentinel 880D
SN: D9269
Source: Ir-192; 89.6 Ci
Source Model: 424-9
Source SN: 12835P
"Corrective actions or reports as well as additional information will be updated with a NMED report within 30 days."
State Event Report ID No.: TN-25-014
The following report was received via email by the Tennessee Division of Radiation Health:
"During a scheduled work visit to the TVA Cumberland City facility, a radiography crew was descending an outside set of stairs covered with ice. The worker slipped on the stairs and released the camera which dropped approximately 20 feet to the ground. The team surveyed the area to ensure it was safe to approach the device. After ensuring the device was secured, it was placed into an overpack and transferred back to the licensee's facility. A minor amount of damage was incurred to the rear of the device. The team had no indication that the source was compromised.
Manufacturer: QSA Global
Model: Sentinel 880D
SN: D9269
Source: Ir-192; 89.6 Ci
Source Model: 424-9
Source SN: 12835P
"Corrective actions or reports as well as additional information will be updated with a NMED report within 30 days."
State Event Report ID No.: TN-25-014