Event Notification Report for February 20, 2025
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
02/19/2025 - 02/20/2025
Agreement State
Event Number: 57563
Rep Org: Texas Dept of State Health Services
Licensee: Equistar Chemical
Region: 4
City: La Porte State: TX
County:
License #: L00204
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Tenisha Meadows
Licensee: Equistar Chemical
Region: 4
City: La Porte State: TX
County:
License #: L00204
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Tenisha Meadows
Notification Date: 02/21/2025
Notification Time: 08:36 [ET]
Event Date: 02/20/2025
Event Time: 00:00 [CST]
Last Update Date: 02/21/2025
Notification Time: 08:36 [ET]
Event Date: 02/20/2025
Event Time: 00:00 [CST]
Last Update Date: 02/21/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE - STUCK OPEN SHUTTER
The following information was provided by the Texas Department of State Health Services (the Department) via email:
"On February 20, 2025, the Department was notified by the licensee that the shutter on a Vega SH-F2 nuclear gauge containing a 800 millicurie (original activity) Cs-137 source was found stuck in the open position during routine testing. Open is the normal position for the shutter. The licensee will try to close the shutter on February 21, 2025, when temperatures are above 32 degrees Fahrenheit to [determine whether] cold temperatures were a factor. It is a possibility that water was in the internals of the source holder, the water became ice, and then caused the shutter to not function as designed. If it is not a temperature issue, the licensee will pursue other options to repair or replace the source holder. The licensee stated there is no risk of additional radiation exposure to members of the general public or radiation workers, due to this shutter mechanism failure. Additional information will be provided as it is received in accordance with SA-300."
Texas Incident Number: 10170
Texas NMED number: TX250011
* * * UPDATE ON 02/21/25 AT 1508 EST FROM ART TUCKER TO KAREN COTTON * * *
"On February 21, 2025, the licensee stated the gauge shutter was tested and the shutter operated as designed. The licensee reported, 'There must have been ice inside the source holder.' The Department has requested additional information."
Notified R4DO(Dixon) and NMSS Events (email)
The following information was provided by the Texas Department of State Health Services (the Department) via email:
"On February 20, 2025, the Department was notified by the licensee that the shutter on a Vega SH-F2 nuclear gauge containing a 800 millicurie (original activity) Cs-137 source was found stuck in the open position during routine testing. Open is the normal position for the shutter. The licensee will try to close the shutter on February 21, 2025, when temperatures are above 32 degrees Fahrenheit to [determine whether] cold temperatures were a factor. It is a possibility that water was in the internals of the source holder, the water became ice, and then caused the shutter to not function as designed. If it is not a temperature issue, the licensee will pursue other options to repair or replace the source holder. The licensee stated there is no risk of additional radiation exposure to members of the general public or radiation workers, due to this shutter mechanism failure. Additional information will be provided as it is received in accordance with SA-300."
Texas Incident Number: 10170
Texas NMED number: TX250011
* * * UPDATE ON 02/21/25 AT 1508 EST FROM ART TUCKER TO KAREN COTTON * * *
"On February 21, 2025, the licensee stated the gauge shutter was tested and the shutter operated as designed. The licensee reported, 'There must have been ice inside the source holder.' The Department has requested additional information."
Notified R4DO(Dixon) and NMSS Events (email)
Agreement State
Event Number: 57564
Rep Org: Texas Dept of State Health Services
Licensee: Equistar Chemicals LP
Region: 4
City: Bay City State: TX
County:
License #: L03938
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Tenisha Meadows
Licensee: Equistar Chemicals LP
Region: 4
City: Bay City State: TX
County:
License #: L03938
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Tenisha Meadows
Notification Date: 02/21/2025
Notification Time: 11:16 [ET]
Event Date: 02/20/2025
Event Time: 00:00 [CST]
Last Update Date: 02/21/2025
Notification Time: 11:16 [ET]
Event Date: 02/20/2025
Event Time: 00:00 [CST]
Last Update Date: 02/21/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE - STUCK OPEN SHUTTER
The following information was provided by the Texas Department of State Health Services (the Department) via email:
"On February 21, 2025, the Department was notified by the licensee that on February 20, 2025, the shutter of a Ronan SA-1 nuclear gauge containing a 20 millicurie (original activity) cesium-137 source was found stuck in the open position during routine testing. Open is the normal position of the shutter. The licensee stated there is no risk of additional radiation exposure to members of the general public or radiation workers, due to this shutter mechanism failure. Additional information will be provided as it is received in accordance with SA-300."
Texas Incident number: 10171
Texas NMED number: TX250012
The following information was provided by the Texas Department of State Health Services (the Department) via email:
"On February 21, 2025, the Department was notified by the licensee that on February 20, 2025, the shutter of a Ronan SA-1 nuclear gauge containing a 20 millicurie (original activity) cesium-137 source was found stuck in the open position during routine testing. Open is the normal position of the shutter. The licensee stated there is no risk of additional radiation exposure to members of the general public or radiation workers, due to this shutter mechanism failure. Additional information will be provided as it is received in accordance with SA-300."
Texas Incident number: 10171
Texas NMED number: TX250012
Agreement State
Event Number: 57568
Rep Org: Maryland Dept of the Environment
Licensee: Johns Hopkins Imaging
Region: 1
City: Bethesda State: MD
County:
License #: 31-314-01
Agreement: Y
Docket:
NRC Notified By: Krishnakumar Nangeelil
HQ OPS Officer: Karen Cotton-Gross
Licensee: Johns Hopkins Imaging
Region: 1
City: Bethesda State: MD
County:
License #: 31-314-01
Agreement: Y
Docket:
NRC Notified By: Krishnakumar Nangeelil
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 02/24/2025
Notification Time: 13:16 [ET]
Event Date: 02/20/2025
Event Time: 00:00 [EST]
Last Update Date: 02/24/2025
Notification Time: 13:16 [ET]
Event Date: 02/20/2025
Event Time: 00:00 [EST]
Last Update Date: 02/24/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - LEAKING SEALED SOURCE
The following information was provided by the Maryland Department of the Environment (MDE) via email:
"On February 20, 2025, an incident involving a sealed radioactive source [leaking source] at the PET/CT Department of Johns Hopkins Imaging, Bethesda was reported to the MDE. The issue was identified during a routine leak test conducted by the facility's health physics consultant, Krueger Gilbert Health Physics. The sealed vial source, Cs-137 (Serial Number 16694, activity 0.199 mCi as of March 1, 2002), was used for quality control of the Capintec CRC dose calibrator.
"Upon detection of the issue, the sealed source was immediately withdrawn from service, placed in a polythene zip-lock bag, and securely stored in the hot lab. A comprehensive contamination survey was conducted by collecting wipe samples from the dose calibrator, handling tools, storage container, storage area, and other relevant locations. The survey results confirmed no detectable radioactive contamination.
"As a precautionary measure, the licensee was instructed to maintain the sealed source in double-sealed polythene packaging within a secure container. The licensee is currently awaiting a return kit for the proper disposal of the source through an authorized agency or supplier. Upon completion of the disposal process, all relevant documentation will be submitted to MDE.
"MDE will provide follow up to this reactive investigation until the source is securely disposed."
The following information was provided by the Maryland Department of the Environment (MDE) via email:
"On February 20, 2025, an incident involving a sealed radioactive source [leaking source] at the PET/CT Department of Johns Hopkins Imaging, Bethesda was reported to the MDE. The issue was identified during a routine leak test conducted by the facility's health physics consultant, Krueger Gilbert Health Physics. The sealed vial source, Cs-137 (Serial Number 16694, activity 0.199 mCi as of March 1, 2002), was used for quality control of the Capintec CRC dose calibrator.
"Upon detection of the issue, the sealed source was immediately withdrawn from service, placed in a polythene zip-lock bag, and securely stored in the hot lab. A comprehensive contamination survey was conducted by collecting wipe samples from the dose calibrator, handling tools, storage container, storage area, and other relevant locations. The survey results confirmed no detectable radioactive contamination.
"As a precautionary measure, the licensee was instructed to maintain the sealed source in double-sealed polythene packaging within a secure container. The licensee is currently awaiting a return kit for the proper disposal of the source through an authorized agency or supplier. Upon completion of the disposal process, all relevant documentation will be submitted to MDE.
"MDE will provide follow up to this reactive investigation until the source is securely disposed."
Agreement State
Event Number: 57562
Rep Org: Colorado Dept of Health
Licensee: Ritz Carlton - Avon
Region: 4
City: Avon State: CO
County:
License #: GL001060
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Josue Ramirez
Licensee: Ritz Carlton - Avon
Region: 4
City: Avon State: CO
County:
License #: GL001060
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Josue Ramirez
Notification Date: 02/20/2025
Notification Time: 15:46 [ET]
Event Date: 02/20/2025
Event Time: 00:00 [MST]
Last Update Date: 02/20/2025
Notification Time: 15:46 [ET]
Event Date: 02/20/2025
Event Time: 00:00 [MST]
Last Update Date: 02/20/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
AGREEMENT STATE REPORT - LOST EXIT SIGNS
The following is a summary of information received from the Colorado Department of Public Health and Environment via email:
Six exit signs, each containing 11.5 curies of tritium (69 curies total), were determined to be lost by the licensee.
Manufacturer: Safety Light Corporation
Model Number: SLX60
Colorado Event Number: CO250003
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of information received from the Colorado Department of Public Health and Environment via email:
Six exit signs, each containing 11.5 curies of tritium (69 curies total), were determined to be lost by the licensee.
Manufacturer: Safety Light Corporation
Model Number: SLX60
Colorado Event Number: CO250003
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf