Event Notification Report for January 12, 2024
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
01/11/2024 - 01/12/2024
Part 21
Event Number: 56919
Rep Org: V. C. Summer
Licensee: V. C. Summer
Region: 2
City: Jenkinsville State: SC
County: Franklin
License #:
Agreement: Y
Docket:
NRC Notified By: Justin booknight
HQ OPS Officer: Thomas Herrity
Licensee: V. C. Summer
Region: 2
City: Jenkinsville State: SC
County: Franklin
License #:
Agreement: Y
Docket:
NRC Notified By: Justin booknight
HQ OPS Officer: Thomas Herrity
Notification Date: 01/10/2024
Notification Time: 08:18 [ET]
Event Date: 11/12/2021
Event Time: 00:00 [EST]
Last Update Date: 01/10/2024
Notification Time: 08:18 [ET]
Event Date: 11/12/2021
Event Time: 00:00 [EST]
Last Update Date: 01/10/2024
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Miller, Mark (R2DO)
Part 21/50.55 Reactors, - (EMAIL)
Miller, Mark (R2DO)
Part 21/50.55 Reactors, - (EMAIL)
PART 21 - EATON-CUTLER HAMMER RELAY ON EMERGENCY DIESEL FAILED
The following information was provided by the licensee via email and phone call:
"On January 9, 2024, VC Summer Nuclear Station (VCSNS) determined a manufacturing defect affecting a control power circuit monitor (CP1) relay on its 'B' emergency diesel generator (EDG) was reportable under Part 21.
"On November 12, 2021, the 'B' EDG was rendered inoperable when its CP1 relay de-energized due to mechanical binding of the magnet carrier assembly. The binding was caused by a manufacturing defect that allowed heat-induced shrinkage to reduce the clearance between the magnet carrier and adjacent coil housing and base, preventing it from moving freely. VCSNS replaced the effected relay and restored operability of its 'B' EDG.
"Manufacturer/Model: Eaton-Cutler Hammer D26MRD30A1
"A written notification in accordance with 10 CFR 21.21(d)(3)(ii) will be provided within 30 days. The NRC Senior Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The plant has notified the manufacturer. It is not known if any other plants are affected by this defect.
The following information was provided by the licensee via email and phone call:
"On January 9, 2024, VC Summer Nuclear Station (VCSNS) determined a manufacturing defect affecting a control power circuit monitor (CP1) relay on its 'B' emergency diesel generator (EDG) was reportable under Part 21.
"On November 12, 2021, the 'B' EDG was rendered inoperable when its CP1 relay de-energized due to mechanical binding of the magnet carrier assembly. The binding was caused by a manufacturing defect that allowed heat-induced shrinkage to reduce the clearance between the magnet carrier and adjacent coil housing and base, preventing it from moving freely. VCSNS replaced the effected relay and restored operability of its 'B' EDG.
"Manufacturer/Model: Eaton-Cutler Hammer D26MRD30A1
"A written notification in accordance with 10 CFR 21.21(d)(3)(ii) will be provided within 30 days. The NRC Senior Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The plant has notified the manufacturer. It is not known if any other plants are affected by this defect.
Part 21
Event Number: 56920
Rep Org: V. C. Summer
Licensee: V. C. Summer
Region: 2
City: Jenkinsville State: SC
County: Franklin
License #:
Agreement: Y
Docket:
NRC Notified By: Justin BoUkknight
HQ OPS Officer: Thomas Herrity
Licensee: V. C. Summer
Region: 2
City: Jenkinsville State: SC
County: Franklin
License #:
Agreement: Y
Docket:
NRC Notified By: Justin BoUkknight
HQ OPS Officer: Thomas Herrity
Notification Date: 01/10/2024
Notification Time: 08:18 [ET]
Event Date: 05/05/2021
Event Time: 00:00 [EST]
Last Update Date: 01/10/2024
Notification Time: 08:18 [ET]
Event Date: 05/05/2021
Event Time: 00:00 [EST]
Last Update Date: 01/10/2024
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Miller, Mark (R2DO)
Part 21/50.55 Reactors, - (EMAIL)
Miller, Mark (R2DO)
Part 21/50.55 Reactors, - (EMAIL)
PART 21 - GOULD FIELD FLASH RELAY ON EMERGENCY DIESEL FAILED
The following information was provided by the licensee via email and phone call:
"On January 9, 2024, VC Summer Nuclear Station (VCSNS) determined a manufacturing defect affecting a field flash contactor (K2) relay on its 'B' emergency diesel generator (EDG) was reportable under Part 21.
"During testing on May 5, 2021, the 'B' EDG was rendered inoperable when its K2 relay coil switch exhibited intermittent binding due to insufficient clearances of the switch actuator from the protective case and plastic switch molding. The inadequate clearances resulted in accelerated loss of graphite lubrication at these locations, which led to mechanical binding. VCSNS replaced the effected relay and restored operability of its 'B' EDG.
"Manufacturer/Model: Gould F10NOCLD1 DC coil switch
"A written notification in accordance with 10 CFR 21.21(d)(3)(ii) will be provided within 30 days. The NRC Senior Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The licensee did not notify the intellectual property owner because the manufacturer is no longer operating or in business. They are not aware of other plants that utilize this coil switch.
The following information was provided by the licensee via email and phone call:
"On January 9, 2024, VC Summer Nuclear Station (VCSNS) determined a manufacturing defect affecting a field flash contactor (K2) relay on its 'B' emergency diesel generator (EDG) was reportable under Part 21.
"During testing on May 5, 2021, the 'B' EDG was rendered inoperable when its K2 relay coil switch exhibited intermittent binding due to insufficient clearances of the switch actuator from the protective case and plastic switch molding. The inadequate clearances resulted in accelerated loss of graphite lubrication at these locations, which led to mechanical binding. VCSNS replaced the effected relay and restored operability of its 'B' EDG.
"Manufacturer/Model: Gould F10NOCLD1 DC coil switch
"A written notification in accordance with 10 CFR 21.21(d)(3)(ii) will be provided within 30 days. The NRC Senior Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The licensee did not notify the intellectual property owner because the manufacturer is no longer operating or in business. They are not aware of other plants that utilize this coil switch.
Non-Agreement State
Event Number: 56892
Rep Org: JAN X-Ray Services, Inc.
Licensee: JAN X-Ray Services, Inc.
Region: 3
City: Parma State: MI
County:
License #: 21-16560-01
Agreement: N
Docket:
NRC Notified By: James Maramba
HQ OPS Officer: Thomas Herrity
Licensee: JAN X-Ray Services, Inc.
Region: 3
City: Parma State: MI
County:
License #: 21-16560-01
Agreement: N
Docket:
NRC Notified By: James Maramba
HQ OPS Officer: Thomas Herrity
Notification Date: 12/15/2023
Notification Time: 16:16 [ET]
Event Date: 12/15/2023
Event Time: 06:52 [EST]
Last Update Date: 01/12/2024
Notification Time: 16:16 [ET]
Event Date: 12/15/2023
Event Time: 06:52 [EST]
Last Update Date: 01/12/2024
Emergency Class: Non Emergency
10 CFR Section:
20.2202(b)(1) - Pers Overexposure/TEDE >= 5 Rem
10 CFR Section:
20.2202(b)(1) - Pers Overexposure/TEDE >= 5 Rem
Person (Organization):
McCraw, Aaron (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
McCraw, Aaron (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 1/16/2024
EN Revision Text: NON-AGREEMENT STATE - POSSIBLE EXPOSURE ABOVE LIMIT (TEDE > 5 rem)
The following is a synopsis of information provided by the licensee via phone call:
On December 15, 2023, at 0652 EST, JAN X-ray Services received notification from the laboratory performing regularly scheduled analysis of their employee's thermoluminescent dosimeters (TLDs) that one of the units is indicating an employee received a dose of 5.729 rem. The limit is 5.0 rem. The worker is not normally involved in radiography. The licensee is investigating how the employee received the indicated dose.
* * * RETRACTION ON 01/12/24 AT 0934 EST FROM JAMES MARAMBA TO KERBY SCALES * * *
The following retraction is a summary of information provided by the licensee via email:
JAN X-Ray Services requested the event be retracted based on findings that indicated that the exposure was to whole-body monitoring badge and not the individual.
Notified R3DO (Szwarc) and NMSS Event Notifications via email.
EN Revision Text: NON-AGREEMENT STATE - POSSIBLE EXPOSURE ABOVE LIMIT (TEDE > 5 rem)
The following is a synopsis of information provided by the licensee via phone call:
On December 15, 2023, at 0652 EST, JAN X-ray Services received notification from the laboratory performing regularly scheduled analysis of their employee's thermoluminescent dosimeters (TLDs) that one of the units is indicating an employee received a dose of 5.729 rem. The limit is 5.0 rem. The worker is not normally involved in radiography. The licensee is investigating how the employee received the indicated dose.
* * * RETRACTION ON 01/12/24 AT 0934 EST FROM JAMES MARAMBA TO KERBY SCALES * * *
The following retraction is a summary of information provided by the licensee via email:
JAN X-Ray Services requested the event be retracted based on findings that indicated that the exposure was to whole-body monitoring badge and not the individual.
Notified R3DO (Szwarc) and NMSS Event Notifications via email.
Non-Agreement State
Event Number: 56916
Rep Org: St Luke's Regional Medical Center
Licensee: St Luke's Regional Medical Center
Region: 4
City: Boise State: ID
County:
License #: 11-27312-01
Agreement: N
Docket:
NRC Notified By: Scott Fuller
HQ OPS Officer: Karen Cotton-Gross
Licensee: St Luke's Regional Medical Center
Region: 4
City: Boise State: ID
County:
License #: 11-27312-01
Agreement: N
Docket:
NRC Notified By: Scott Fuller
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 01/09/2024
Notification Time: 13:18 [ET]
Event Date: 01/08/2024
Event Time: 00:00 [MST]
Last Update Date: 01/11/2024
Notification Time: 13:18 [ET]
Event Date: 01/08/2024
Event Time: 00:00 [MST]
Last Update Date: 01/11/2024
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
Person (Organization):
Gaddy, Vincent (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Gaddy, Vincent (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
MEDICAL EVENT - Y-90 UNDERDOSE
The following information was provided by St. Luke's Regional Medical Center via email:
"The authorized user was performing a yttrium-90 (Y-90) procedure on January 8, 2024. The prescribed activity to be administered was 3.9 GBq, per the written directive. During the procedure, the authorized user paused the administration when they thought that there may have been a leak in one of the connection points. After verifying that there was no leakage occurring, administration resumed as normal. The post-procedure assay of tubing and vial showed that only 3.1 GBq was delivered. There was no spill involved and all remaining activity was contained within the delivery tube.
"Actual dose to the target volume was still at an appropriate range, per the provider. It is not expected that an additional delivery of Y-90 will be scheduled at this time.
"A representative from TheraSphere has been contacted for post-administration inspection of procedure and equipment."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * RETRACTION ON 01/11/24 AT 1547 EDT FROM SCOTT FULLER TO IAN HOWARD * * *
"After further review of the administration records, patient and organ doses, and administered activities, along with a better understanding of the Y-90 Licensing Guidance, we are requesting that this event notification be withdrawn."
Notified R4DO (Gaddy), NMSS Events (email).
The following information was provided by St. Luke's Regional Medical Center via email:
"The authorized user was performing a yttrium-90 (Y-90) procedure on January 8, 2024. The prescribed activity to be administered was 3.9 GBq, per the written directive. During the procedure, the authorized user paused the administration when they thought that there may have been a leak in one of the connection points. After verifying that there was no leakage occurring, administration resumed as normal. The post-procedure assay of tubing and vial showed that only 3.1 GBq was delivered. There was no spill involved and all remaining activity was contained within the delivery tube.
"Actual dose to the target volume was still at an appropriate range, per the provider. It is not expected that an additional delivery of Y-90 will be scheduled at this time.
"A representative from TheraSphere has been contacted for post-administration inspection of procedure and equipment."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * RETRACTION ON 01/11/24 AT 1547 EDT FROM SCOTT FULLER TO IAN HOWARD * * *
"After further review of the administration records, patient and organ doses, and administered activities, along with a better understanding of the Y-90 Licensing Guidance, we are requesting that this event notification be withdrawn."
Notified R4DO (Gaddy), NMSS Events (email).
Agreement State
Event Number: 56917
Rep Org: Texas Dept of State Health Services
Licensee: Union Carbide Corporation
Region: 4
City: Seadrift State: TX
County:
License #: L-00051
Agreement: Y
Docket:
NRC Notified By: Arthur Tucker
HQ OPS Officer: Bill Gott
Licensee: Union Carbide Corporation
Region: 4
City: Seadrift State: TX
County:
License #: L-00051
Agreement: Y
Docket:
NRC Notified By: Arthur Tucker
HQ OPS Officer: Bill Gott
Notification Date: 01/09/2024
Notification Time: 17:10 [ET]
Event Date: 01/09/2024
Event Time: 00:00 [CST]
Last Update Date: 01/09/2024
Notification Time: 17:10 [ET]
Event Date: 01/09/2024
Event Time: 00:00 [CST]
Last Update Date: 01/09/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Gaddy, Vincent (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Gaddy, Vincent (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE - SHUTTER STUCK IN OPEN POSITION
The following information was provided by the Texas Department of State Health Services (the Department) via email:
"On January 9, 2024, the Department was notified by the licensee's radiation safety officer (RSO) that during routine checks, the shutters on three Vega America SH-F2 source holder failed to close. Open is the normal operating position for the gauges. Each gauge contains a 200 millicurie cesium-137 source. The gauges do not create an exposure risk to any individual. The RSO stated they have contacted a service provider for repairs to the gauges. Additional information will be provided as it is received in accordance with SA300."
Texas Incident Number: I-10076
NMED Number: TX240001
The following information was provided by the Texas Department of State Health Services (the Department) via email:
"On January 9, 2024, the Department was notified by the licensee's radiation safety officer (RSO) that during routine checks, the shutters on three Vega America SH-F2 source holder failed to close. Open is the normal operating position for the gauges. Each gauge contains a 200 millicurie cesium-137 source. The gauges do not create an exposure risk to any individual. The RSO stated they have contacted a service provider for repairs to the gauges. Additional information will be provided as it is received in accordance with SA300."
Texas Incident Number: I-10076
NMED Number: TX240001
Agreement State
Event Number: 56918
Rep Org: California Radiation Control Prgm
Licensee: Harrington Geotechnical Engineering, Inc.
Region: 4
City: Lake Forest State: CA
County:
License #: 5657-30
Agreement: Y
Docket:
NRC Notified By: Robert Greger
HQ OPS Officer: Bill Gott
Licensee: Harrington Geotechnical Engineering, Inc.
Region: 4
City: Lake Forest State: CA
County:
License #: 5657-30
Agreement: Y
Docket:
NRC Notified By: Robert Greger
HQ OPS Officer: Bill Gott
Notification Date: 01/09/2024
Notification Time: 20:10 [ET]
Event Date: 01/08/2024
Event Time: 00:00 [PST]
Last Update Date: 01/09/2024
Notification Time: 20:10 [ET]
Event Date: 01/08/2024
Event Time: 00:00 [PST]
Last Update Date: 01/09/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Gaddy, Vincent (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
CNSNS (Mexico) (EMAIL)
Gaddy, Vincent (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
CNSNS (Mexico) (EMAIL)
AGREEMENT STATE - STOLEN GAUGE
The following information was provided by the California Department of Public Health, Radiation Health Branch via email:
"On January 8, 2024, the licensee's radiation safety officer contacted the California Office of Emergency Services to report a moisture/density gauge was stolen from a vehicle (Honda Pilot SUV) that was parked at the operator's residence. The gauge transport case was locked, as was the gauge inside the case, and the case was secured to the frame of the locked vehicle with a lock and chain. The gauge was a CPN model MC-3, serial number M339028680 containing 10 mCi Cs-137 (nominal) and 50 mCi Am:Be-241 (nominal). A police report was submitted to the Orange County Sherriff's Department. An advertisement has been submitted to the Orange County Register with a reward for return of the gauge. The licensee's investigation into this event is ongoing and will be reviewed further by the California Department of Public Health."
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was provided by the California Department of Public Health, Radiation Health Branch via email:
"On January 8, 2024, the licensee's radiation safety officer contacted the California Office of Emergency Services to report a moisture/density gauge was stolen from a vehicle (Honda Pilot SUV) that was parked at the operator's residence. The gauge transport case was locked, as was the gauge inside the case, and the case was secured to the frame of the locked vehicle with a lock and chain. The gauge was a CPN model MC-3, serial number M339028680 containing 10 mCi Cs-137 (nominal) and 50 mCi Am:Be-241 (nominal). A police report was submitted to the Orange County Sherriff's Department. An advertisement has been submitted to the Orange County Register with a reward for return of the gauge. The licensee's investigation into this event is ongoing and will be reviewed further by the California Department of Public Health."
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf