Event Notification Report for November 14, 2023

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/13/2023 - 11/14/2023

Agreement State
Event Number: 56835
Rep Org: Wisconsin Radiation Protection
Licensee: City Brewing Company, LLC
Region: 3
City: La Crosse   State: WI
County:
License #: WI230021
Agreement: Y
Docket:
NRC Notified By: Patrick Schendel
HQ OPS Officer: Donald Norwood
Notification Date: 11/06/2023
Notification Time: 16:19 [ET]
Event Date: 11/06/2023
Event Time: 14:08 [CST]
Last Update Date: 11/10/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Ruiz, Robert (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSC (Canada), - (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST NUCLEAR GAUGE

The following information was received from the Wisconsin Department of Health Services (the Department) via email:

"On November 06, 2023, at 1408 CST, the Department received a notification from the licensee that a Peco Controls Corporation gauge (serial number 5450LA) containing 100 mCi of Am-241 had been determined to be missing while conducting inventory of gauges in storage. This is all the information that is known at this time. The Department will follow up and provide additional information as it becomes available."

Wisconsin Event Report ID No.: WI230021

* * * UPDATE ON 11/10/23 AT 1605 EST FROM MEGAN SHOBER TO ERIC SIMPSON * * *

The following update was received from the Wisconsin Department of Health Services (the Department) via phone and email:

"On November 10, 2023, the licensee determined that an additional four Peco Controls Gamma 101P gauges were missing (serial numbers 0550LX, 9145LV, 9142LV, and 9580LV). Each gauge contained 300 millicuries of Americium-241. Department inspectors were onsite and physically verified the remainder of the licensee's inventory.

"In addition, the model number of the gauge declared missing on November 6, 2023 was confirmed to be a Gamma 101P."

Notified R3DO (Ruiz), NMSS Event Notifications, ILTAB, and CNSC via email.

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 56836
Rep Org: Colorado Dept of Health
Licensee: Fairfield Inn by Marriott
Region: 4
City: Lakewood   State: CO
County:
License #: GL0000212
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Ernest West
Notification Date: 11/07/2023
Notification Time: 10:16 [ET]
Event Date: 10/30/2023
Event Time: 00:00 [MST]
Last Update Date: 11/07/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Warnick, Greg (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST EXIT SIGNS

The following is a synopsis of information provided by the Colorado Department of Public Health and Environment via email:

On 10/30/23, the licensee discovered that 11 tritium exit signs were not able to be located. The exit signs were SRB Technologies (model number BX-10-BK) signs each containing 10 Ci of tritium (H-3). This is being reported under Colorado Regulations Section 4.51.1.1 (10 CFR 20.2202(a)(1)(i)).

Event Report ID No.: CO230040

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 56837
Rep Org: Florida Bureau of Radiation Control
Licensee: Environmental Safety Consultant Florida, LLC
Region: 1
City: Fort Myers   State: FL
County:
License #: 3440-6
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 11/07/2023
Notification Time: 12:46 [ET]
Event Date: 11/07/2023
Event Time: 11:30 [EST]
Last Update Date: 11/07/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Eve, Elise (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - DAMAGED MOISTURE DENSITY GAUGE

The following information was provided by the Florida Bureau of Radiation Control (BRC) via email:

A Radiation Safety Officer (RSO) with Environmental Safety Consultant (ESC) Florida, LLC called BRC in Orlando on November 7, 2023, at 1150 EST to report a soil moisture density gauge (Model: Instro Tek Xplorer 3500, 8 mCi Cs-137, 40 mCi Am-241:Be) was run over on a job site around 1130 this morning. The RSO indicated that the source rod was retracted when the incident occurred. An inspector was sent to investigate.

Florida Event Number: FL23-161


Power Reactor
Event Number: 56850
Facility: Watts Bar
Region: 2     State: TN
Unit: [2] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Sean Lorson
HQ OPS Officer: Dan Livermore
Notification Date: 11/12/2023
Notification Time: 22:02 [ET]
Event Date: 11/12/2023
Event Time: 03:00 [EST]
Last Update Date: 11/12/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Miller, Mark (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Defueled 0 Defueled
Event Text
EN Revision Imported Date: 11/14/2023

EN Revision Text: OFFSITE NOTIFICATION

The following information was provided by the licensee via email:

"On November 12, 2023, at 0300 EST, a Watts Bar contractor was transported offsite for medical treatment due to a work-related injury. Upon arrival at an offsite medical facility, medical personnel determined the injury required the individual to be admitted into the hospital and will be kept overnight. The individual was inside of the Radiological Controlled Area, however was free released with no contamination.

"The injury and hospitalization were reported to the Occupational Safety and Health Administration (OSHA) under 29 CFR 1904.39(a)(2). The contracting agency informed OSHA at 1319 EST. Watt Bar Operations personnel were officially notified by the contracting agency of the report made to OSHA at 1945 EST.

"This is a four-hour notification, non-emergency for a notification of other government agency. This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi).

"The NRC Resident Inspector has been notified."


Agreement State
Event Number: 56842
Rep Org: Colorado Dept of Health
Licensee: Five Rivers Cattle Feeding
Region: 4
City: Lamar   State: CO
County:
License #: GL002209
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 11/08/2023
Notification Time: 16:01 [ET]
Event Date: 11/08/2023
Event Time: 00:00 [MST]
Last Update Date: 11/08/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Warnick, Greg (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST EXIT SIGN

The following information was obtained and summarized from the Colorado Department of Public Health and Environment in accordance with Headquarters Operations Officers Report Guidance:

On November 8, 2023, Five Rivers Cattle Feeding (Lamar) reported to the Colorado Department of Public Health and Environment one lost exit sign (Manufacturer: Isolite Corporation; Model #: SLX60; Isotope & activity: H-3, 6.2 Ci).

Event Report ID No.: CO230041

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Power Reactor
Event Number: 56852
Facility: Farley
Region: 2     State: AL
Unit: [2] [] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Roosevelt Scott
HQ OPS Officer: Ernest West
Notification Date: 11/14/2023
Notification Time: 14:36 [ET]
Event Date: 11/14/2023
Event Time: 10:41 [CST]
Last Update Date: 11/14/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Miller, Mark (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 10 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP

The following information was provided by the licensee via phone and email:

"At 1041 CST on 11/14/23 with Farley Unit 2 in Mode 1 at 10 percent power, the reactor was manually tripped due to rising steam generator levels. The trip was not complex, with all systems responding normally post-trip.

"Operations responded and stabilized the plant. Auxiliary feedwater (AFW) was manually initiated in accordance with plant procedures and is feeding the steam generators. Heat removal is being provided via the atmospheric relief valves. Unit 1 is not affected.

"Due to the reactor protection system actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B). This event is also being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the auxiliary feedwater system.

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."


The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:

All rods fully inserted. The licensee attempted to take manual control of the feedwater control valves to lower steam generator level but, due to reaching a steam generator level that requires a manual trip, the licensee manually tripped the reactor.