Event Notification Report for June 20, 2023

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/19/2023 - 06/20/2023

Agreement State
Event Number: 56571
Rep Org: Colorado Dept of Health
Licensee: Sky Ridge Medical Center
Region: 4
City: Lone Tree   State: CO
County:
License #: CO 1053-01
Agreement: Y
Docket:
NRC Notified By: Heather Gilbert
HQ OPS Officer: Bill Gott
Notification Date: 06/13/2023
Notification Time: 13:00 [ET]
Event Date: 06/12/2023
Event Time: 11:00 [MDT]
Last Update Date: 06/15/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Warnick, Greg (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - LEAKING SOURCE

The following information was provided by the the Colorado Department of Health via email:

"On June 12, 2023, as the semi-annual leak tests/inventory were being performed at Sky Ridge Medical Center (RAML 1053-01), a leaking Co-57 Benchmark mini flood source (SN BM552021321103) was found. The exact timing of when the source started leaking is unknown. The source was last inventoried in December 2022, and was at background. [A staff member] from the Colorado Associates in Medical Physics (CAMP) found the source had 185 Bq (0.005 micro-Ci) or more removable contamination in excess of the regulatory limits. The initial removable contamination resulted in a wipe count of 3835 cpm (0.00525 micro-Ci) of removable contamination. The source was cleaned with paper towels and dish soap and when re-wiped had a lower count (1900 cpm), but remained above background even after additional wipes. All paper towels used for cleaning surveyed at background (0.03 mR/hr) and were disposed of in the hot trash in the hot lab.

"The source was wrapped in a thick trash bag, secured with tape and was placed in the shielded decay cabinet. The activity of the source on 6/12/2023 was 5.02 milli-Ci. The storage container, the cardiac single-photon emission computed tomography camera, and the hot lab counters were all wiped and surveyed, and all readings were at background (0.03 mR/hr).

"The source did not appear damaged or broken. CAMP will dispose of the source, and they have initiated a disposal inquiry. In the meantime, the source will remain in the shielded decay cabinet."

Colorado event report ID number: CO230016


Power Reactor
Event Number: 56576
Facility: Byron
Region: 3     State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: John Conroy
HQ OPS Officer: Adam Koziol
Notification Date: 06/15/2023
Notification Time: 09:35 [ET]
Event Date: 06/14/2023
Event Time: 09:26 [CDT]
Last Update Date: 06/15/2023
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Peterson, Hironori (R3DO)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS-FOR-DUTY REPORT

The following is a summary of information provided by the licensee via email:

A non-licensed, non-supervisory employee was identified bringing a prohibited item into the protected area. The employee's access to the plant has been terminated.

The NRC Resident Inspector has been notified.


Non-Power Reactor
Event Number: 56579
Rep Org: Oregon State University (OREG)
Licensee: Oregon State University
Region: 0
City: Corvallis   State: OR
County: Benton
License #: R-106
Agreement: Y
Docket: 05000243
NRC Notified By: Steve Reese
HQ OPS Officer: Donald Norwood
Notification Date: 06/16/2023
Notification Time: 13:25 [ET]
Event Date: 05/31/2023
Event Time: 09:30 [PDT]
Last Update Date: 06/16/2023
Emergency Class: Non Emergency
10 CFR Section:
Person (Organization):
Balazik, Michael (NRR PM)
Waugh, Andrew (NPR ENC)
Event Text
TECHNICAL SPECIFICATIONS POWER LIMIT VIOLATION

The following information was provided by the licensee via phone and email:

"[Oregon State University Radiation Center is] providing this information as a follow-up with the phone call to the Headquarters Operations Center made today at 1325 EDT (EN-56579). On the morning of 5/31/2023, a senior reactor operator and a trainee operator were performing a square-wave operation to raise power from 100 W to 1 MW. After firing the transient rod, the reactor immediately scrammed on both safety and percent power channels. Review of the chart recorder shows that reactor power likely reached 1.45 MW. This is potentially a violation of Technical Specification 3.1.1 which limits power to 1.1 MW during steady-state operations.

"Reviewing the power chart recorder, it appears that two immediately adjacent steps required for the square-wave operation were performed inadvertently out of order. The chart's sample rate is 1 Hz, so the resolution on the data is limited. Within 10 seconds, the final procedure steps for square-wave operation were performed (with the mode switch in square-wave mode). Once the transient rod air actuation button was pushed, starting the square-wave, the safety channel shortly thereafter (approximately 1 second) went from 0.02 percent to 145.91 percent of 1 MW. The reactor immediately scrammed and shut down the reactor as the safety and percent power channels exceeded their scram setpoints of 106 percent of 1 MW, which were checked on the daily startup checklist. The cause of the event was that two steps in the procedure were performed out of order, causing the regulating rod to withdraw to match demand power as the transient rod withdrew. As a result, this caused an additional 18 cents of reactivity to be inserted above the planned reactivity insertion of 80 cents.

"[Oregon State University Radiation Center plans] on following this up with a more thorough report within 14 days."


Power Reactor
Event Number: 56580
Facility: Comanche Peak
Region: 4     State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Casey Davies
HQ OPS Officer: Donald Norwood
Notification Date: 06/16/2023
Notification Time: 22:16 [ET]
Event Date: 06/16/2023
Event Time: 18:32 [CDT]
Last Update Date: 06/16/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Warnick, Greg (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 Power Operation 0 Hot Standby
Event Text
AUTOMATIC REACTOR TRIP DUE TO LO-LO STEAM GENERATOR LEVEL

The following information was provided by the licensee via email:

"[On June 16, 2023,] at 1832 CDT, Unit 1 reactor automatically tripped on lo-lo level in the '1-04' steam generator (SG). Prior to the trip, the 1B [main feedwater pump] (MFP) tripped due to speed oscillations and a runback to 700MW was in progress. Both motor driven auxiliary feedwater pumps started due to the lo-lo level in SG '1-04'.

"Unit 1 is being maintained in hot standby (Mode 3) in accordance with Integrated Plant Operating Procedure IPO-007A. The Emergency Response Guideline network has been exited. Decay heat is being rejected to the main condenser via the steam dump valves."

The licensee notified the NRC Resident Inspector.

The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:

Unit 1 is in a normal post-trip electrical line-up. There was no effect on Unit 2 due to the Unit 1 trip.


Non-Agreement State
Event Number: 56573
Rep Org: Reid Health
Licensee: Reid Health
Region: 3
City: Richmond   State: IN
County:
License #: 13-03284-02
Agreement: N
Docket:
NRC Notified By: Mary Ellen Weisner
HQ OPS Officer: Adam Koziol
Notification Date: 06/14/2023
Notification Time: 10:12 [ET]
Event Date: 06/14/2023
Event Time: 07:00 [EDT]
Last Update Date: 06/14/2023
Emergency Class: Non Emergency
10 CFR Section:
20.1906(d)(1) - Surface Contam Levels > Limits
Person (Organization):
Peterson, Hironori (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
NON-AGREEMENT STATE - SURFACE CONTAMINATION ON OUTSIDE OF PACKAGE

The following is a summary of information provided by the licensee via telephone:

On 6/14/23 around 0700 EDT, the licensee received three packages containing F-18 sources. Swipe readings on the packages revealed 42333 counts per minute (cpm), 12857 cpm, and 267 cpm. The packages had slightly elevated radiation readings. The radiation safety officer (RSO) and supplier were notified. There was no contamination found inside of the packaging, and the F-18 doses were double sealed without damage. Swipe readings were taken along the delivery path, but no spread of contamination to public spaces was detected. The affected packages were placed in a radiation storage area pending disposal.


Agreement State
Event Number: 56574
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Illinois Emergency Management Agency
Region: 3
City: Springfield   State: IL
County:
License #: IL-01030-01
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Bill Gott
Notification Date: 06/14/2023
Notification Time: 15:32 [ET]
Event Date: 03/02/2023
Event Time: 00:00 [CDT]
Last Update Date: 06/14/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Peterson, Hironori (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST/ABANDONED SOURCE

The following information was provided by the Illinois Emergency Management Agency (the Agency) via email:

"On March 2, 2023, staff with the Illinois Emergency Management Agency and Office of Homeland Security responded to a load of scrap metal that tripped portal monitors in Indiana and was returned under DOT SP-IN-IL-23-001.The load of scrap originated at B.L. Duke in Forest View, IL. Within that load, a small unidentified radium-226 source was identified. It was estimated to contain approximately 150 microcuries of activity. On June 14, 2023, the licensing division learned of the recovery and began an investigation into the applicability of reporting requirements. There are no discernable markings or serial/model numbers. Activity estimates (based on dose rate) would place the source at approximately 150 microcuries. Aside from this source having significantly less activity, this appears to be a Ra-226 radiography source from the early 30's/40's. As this source does not appear to be exempt, it is likely byproduct material as a discrete source of radium and subject to specific licensure. Therefore, it is being reported as a lost/missing source. The source has been placed into the Agency's orphan source collection program and will be disposed of as low level radioactive waste."
Illinois report number: IL230015

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf