Event Notification Report for May 02, 2023
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
05/01/2023 - 05/02/2023
Agreement State
Event Number: 56486
Rep Org: Colorado Dept of Health
Licensee: Denver Scrap Metal Recycle Center
Region: 4
City: Denver State: CO
County:
License #: N/A
Agreement: Y
Docket:
NRC Notified By: Phillip Peterson
HQ OPS Officer: Ian Howard
Licensee: Denver Scrap Metal Recycle Center
Region: 4
City: Denver State: CO
County:
License #: N/A
Agreement: Y
Docket:
NRC Notified By: Phillip Peterson
HQ OPS Officer: Ian Howard
Notification Date: 04/24/2023
Notification Time: 09:22 [ET]
Event Date: 04/18/2023
Event Time: 00:00 [MDT]
Last Update Date: 04/24/2023
Notification Time: 09:22 [ET]
Event Date: 04/18/2023
Event Time: 00:00 [MDT]
Last Update Date: 04/24/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - FOUND RADIOACTIVE SOURCE
The following information was provided by the Colorado Department of Health via email:
"On April 18, 2023, a recycling yard in Denver flagged a load of scrap metal as potentially radioactive. The load was returned to the point of origin and was separated. At that time, a radium-226:beryllium source was identified. The source container was mostly intact. The point of origin (facility name listed above) was able to construct a cement barrier for storing the source until further investigation could be conducted. Measured dose rates around the cement barriers show rates that are indistinguishable from background (gamma and neutron). The markings on the source container indicate the manufacturer as Nuclear Chicago; the model as P21; the activity as 5 mCi radium-226:beryllium; and the reference date as 04/30/1963."
Event Report ID No.: CO230011
The following information was provided by the Colorado Department of Health via email:
"On April 18, 2023, a recycling yard in Denver flagged a load of scrap metal as potentially radioactive. The load was returned to the point of origin and was separated. At that time, a radium-226:beryllium source was identified. The source container was mostly intact. The point of origin (facility name listed above) was able to construct a cement barrier for storing the source until further investigation could be conducted. Measured dose rates around the cement barriers show rates that are indistinguishable from background (gamma and neutron). The markings on the source container indicate the manufacturer as Nuclear Chicago; the model as P21; the activity as 5 mCi radium-226:beryllium; and the reference date as 04/30/1963."
Event Report ID No.: CO230011
Power Reactor
Event Number: 56494
Facility: Hope Creek
Region: 1 State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Christopher Furst
HQ OPS Officer: Karen Cotton-Gross
Region: 1 State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Christopher Furst
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 04/30/2023
Notification Time: 02:30 [ET]
Event Date: 04/30/2023
Event Time: 01:00 [EDT]
Last Update Date: 04/30/2023
Notification Time: 02:30 [ET]
Event Date: 04/30/2023
Event Time: 01:00 [EDT]
Last Update Date: 04/30/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation 50.72(b)(3)(ii)(A) - Degraded Condition
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation 50.72(b)(3)(ii)(A) - Degraded Condition
Person (Organization):
Henrion, Mark (R1DO)
Henrion, Mark (R1DO)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
1 | N | Y | 100 | Power Operation | 100 | Power Operation |
PRIMARY CONTAINMENT INTEGRITY DEGRADED
The following information was provided by the licensee via email:
"At 0100 EDT on 04/30/23, it was determined that the primary containment integrity did not meet [Technical Specification] TS 4.6.1.1.d requirement, suppression chamber in compliance with TS 3.6.2.1 due to the inability to establish test conditions for the bypass leakage test in accordance with TS 4.6.2.1.f.
"This event is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v)(D) & 10 CFR 50.72(b)(3)(ii)(A).
"There was no impact on the health and safety of the public or plant personnel.
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via email:
"At 0100 EDT on 04/30/23, it was determined that the primary containment integrity did not meet [Technical Specification] TS 4.6.1.1.d requirement, suppression chamber in compliance with TS 3.6.2.1 due to the inability to establish test conditions for the bypass leakage test in accordance with TS 4.6.2.1.f.
"This event is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v)(D) & 10 CFR 50.72(b)(3)(ii)(A).
"There was no impact on the health and safety of the public or plant personnel.
"The NRC Resident Inspector has been notified."
Power Reactor
Event Number: 56495
Facility: Hope Creek
Region: 1 State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Christopher Furst
HQ OPS Officer: Karen Cotton-Gross
Region: 1 State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Christopher Furst
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 04/30/2023
Notification Time: 02:30 [ET]
Event Date: 04/30/2023
Event Time: 02:00 [EDT]
Last Update Date: 04/30/2023
Notification Time: 02:30 [ET]
Event Date: 04/30/2023
Event Time: 02:00 [EDT]
Last Update Date: 04/30/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(i) - Plant S/D Reqd By Ts
10 CFR Section:
50.72(b)(2)(i) - Plant S/D Reqd By Ts
Person (Organization):
Henrion, Mark (R1DO)
Henrion, Mark (R1DO)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
1 | N | Y | 100 | Power Operation | 100 | Power Operation |
TECHNICAL SPECIFICATION REQUIRED SHUTDOWN
The following information was provided by the licensee via email:
"At 0200 EDT on 04/30/23, a Technical Specification required shutdown was initiated at Hope Creek Unit 1. Technical Specification Action 3.6.1.1 Primary Containment Integrity was entered on 04/30/23 at 0100 with a required action to restore primary containment integrity within 1 hour. This required action was not completed within the allowed outage time; therefore, a Technical Specification required shutdown was initiated, and this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(i).
"There was no impact on the health and safety of the public or plant personnel.
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via email:
"At 0200 EDT on 04/30/23, a Technical Specification required shutdown was initiated at Hope Creek Unit 1. Technical Specification Action 3.6.1.1 Primary Containment Integrity was entered on 04/30/23 at 0100 with a required action to restore primary containment integrity within 1 hour. This required action was not completed within the allowed outage time; therefore, a Technical Specification required shutdown was initiated, and this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(i).
"There was no impact on the health and safety of the public or plant personnel.
"The NRC Resident Inspector has been notified."
Agreement State
Event Number: 56348
Rep Org: SC Dept of Health & Env Control
Licensee: WestRock Charleston Kraft, LLC
Region: 1
City: Charleston State: SC
County:
License #: SC353
Agreement: Y
Docket:
NRC Notified By: Leland Cave
HQ OPS Officer: Karen Cotton-Gross
Licensee: WestRock Charleston Kraft, LLC
Region: 1
City: Charleston State: SC
County:
License #: SC353
Agreement: Y
Docket:
NRC Notified By: Leland Cave
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 02/10/2023
Notification Time: 09:21 [ET]
Event Date: 02/09/2023
Event Time: 15:34 [EST]
Last Update Date: 05/02/2023
Notification Time: 09:21 [ET]
Event Date: 02/09/2023
Event Time: 15:34 [EST]
Last Update Date: 05/02/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 5/3/2023
EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER GAUGE
The following summary was obtained via phone and email from the South Carolina Department of Health & Environmental Control [the Department]:
On February 9, 2023, at 1534 EST, the Department was notified by WestRock Charleston Kraft, LLC of a shutter on an Ohmart SH-F1 gauging device (serial number 67584) containing 10 mCi of Cs-137 that was stuck in the open position. The shutter was found during the licensee's six month inventory and shutter check. The gauge is in an isolated area not heavily trafficked.
The vat that the gauge is attached to leaks directly onto the gauge, so it was previously recommended that the gauge be covered. The recommendation did not help. The contractor surveyed the gauge and got no higher than 2 mR/hr at a foot. The inspector concurred after using his [model] 14-C [detector] (serial number 99961). The numbers were approximately 4 mR/hr on the outside surface of the covering. It has been decided by the licensee that because it is in a very unobtainable location, they will leave it in the open and operating position until they remove the entire vat from service in March or April.
South Carolina Event Number: EN56348
* * * UPDATE ON 3/9/23 AT 0836 EST FROM THE SOUTH CAROLINA DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL TO BILL GOTT VIA EMAIL * * *
The following summary was obtained via email from the South Carolina Department of Health & Environmental Control:
"The licensee submitted a 30-day written report on 03/09/23. The licensee reported no overexposures and that the gauging device will be disposed by 05/31/23. The licensee also reported that the gauging device contains 100 mCi of Cs-137 and not 10 mCi of Cs-137 as originally reported. This event is still under investigation."
Notified R1DO (Young), and NMSS Events Notification (via email).
* * * UPDATE ON 5/2/23 AT 0908 EDT FROM SOUTH CAROLINA DEPARTMENT OF HEALTH & ENVIRONMENTAL CONTROL TO SAM COLVARD * * *
"The gauging device was transferred for disposal on 4/13/23. This event is considered closed."
Notified R1DO (Dimitriadis), and NMSS Events Notification (via email).
EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER GAUGE
The following summary was obtained via phone and email from the South Carolina Department of Health & Environmental Control [the Department]:
On February 9, 2023, at 1534 EST, the Department was notified by WestRock Charleston Kraft, LLC of a shutter on an Ohmart SH-F1 gauging device (serial number 67584) containing 10 mCi of Cs-137 that was stuck in the open position. The shutter was found during the licensee's six month inventory and shutter check. The gauge is in an isolated area not heavily trafficked.
The vat that the gauge is attached to leaks directly onto the gauge, so it was previously recommended that the gauge be covered. The recommendation did not help. The contractor surveyed the gauge and got no higher than 2 mR/hr at a foot. The inspector concurred after using his [model] 14-C [detector] (serial number 99961). The numbers were approximately 4 mR/hr on the outside surface of the covering. It has been decided by the licensee that because it is in a very unobtainable location, they will leave it in the open and operating position until they remove the entire vat from service in March or April.
South Carolina Event Number: EN56348
* * * UPDATE ON 3/9/23 AT 0836 EST FROM THE SOUTH CAROLINA DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL TO BILL GOTT VIA EMAIL * * *
The following summary was obtained via email from the South Carolina Department of Health & Environmental Control:
"The licensee submitted a 30-day written report on 03/09/23. The licensee reported no overexposures and that the gauging device will be disposed by 05/31/23. The licensee also reported that the gauging device contains 100 mCi of Cs-137 and not 10 mCi of Cs-137 as originally reported. This event is still under investigation."
Notified R1DO (Young), and NMSS Events Notification (via email).
* * * UPDATE ON 5/2/23 AT 0908 EDT FROM SOUTH CAROLINA DEPARTMENT OF HEALTH & ENVIRONMENTAL CONTROL TO SAM COLVARD * * *
"The gauging device was transferred for disposal on 4/13/23. This event is considered closed."
Notified R1DO (Dimitriadis), and NMSS Events Notification (via email).
Hospital
Event Number: 56481
Rep Org: Southern Arizona VA Health Care
Licensee: Southern Arizona VA Health Care
Region: 3
City: Little Rock State: AR
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: Kim Wiebeck
HQ OPS Officer: Sam Colvard
Licensee: Southern Arizona VA Health Care
Region: 3
City: Little Rock State: AR
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: Kim Wiebeck
HQ OPS Officer: Sam Colvard
Notification Date: 04/20/2023
Notification Time: 17:20 [ET]
Event Date: 04/19/2023
Event Time: 12:30 [CDT]
Last Update Date: 05/02/2023
Notification Time: 17:20 [ET]
Event Date: 04/19/2023
Event Time: 12:30 [CDT]
Last Update Date: 05/02/2023
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Orth, Steve (R3DO)
Werner, Greg (EMAIL)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Orth, Steve (R3DO)
Werner, Greg (EMAIL)
EN Revision Imported Date: 5/3/2023
EN Revision Text: MEDICAL EVENT - PATIENT UNDERDOSE
The following information was provided by the licensee via phone and email:
"Per 10 CFR 35.3045(c), Veterans Health Administration (VHA) National Health Physics Program (NHPP) is reporting a possible medical event.
"Southern Arizona VA Health Care System [the facility], Tucson, Arizona, which holds Permit Number 02-06186-01 under the VA master materials license, reported discovery of a 'possible' medical event to NHPP at approximately [1500] CDT, April 19, 2023.
"A yttrium-90 microsphere therapy administration for liver cancer was performed on April 19, 2023. The intended treatment site was hepatic segment 4 of the right lobe of the liver. During the administration, performed under fluoroscopy guidance, the Authorized User (AU) / administering Interventional Radiology physician noted a change in the catheter position and elected to stop the administration. Measurements and calculations indicated the patient received about 63 percent of the prescribed activity [15.06 mCi delivered vs. 21.6 mCi prescribed]. Post implant single-photon emission computerized tomography (SPECT) imaging verified that the dosage had been delivered to the correct location.
"The AU believes that the movement of the catheter qualifies as an emergent patient condition. The written directive was modified to include the reason for not administering the intended activity, the signature of an AU for yttrium-90 microspheres, and the date signed. NHPP in coordination with the facility and NRC will conduct further evaluation of this event to determine if the regulatory definition of emergent patient condition was met.
"The patient and the referring physician have been notified.
"At this time, short term harm to the patient is not expected.
"NHPP will follow up with a written report in accordance with NRC requirements in 10 CFR 35.3045.
"NHPP has notified the NRC Region III Project Manager."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * RETRACTION FROM KIM WIEBECK TO BRIAN P. SMITH AT 1709 EDT ON 05/02/2023 * * *
The following information was provided by the licensee via email:
"Veterans Health Administration (VHA) National Health Physics Program (NHPP) placed a call to NRC Operations Center on May 2, 2023, to retract Event Number 56481 (NMED Item No. 230168).
"NHPP reported discovery of a "possible" medical event at Southern Arizona VA Health Care System, Tucson, Arizona, Permit Number 02-06186-01, on April 19, 2023.
"NHPP, in coordination with the facility and NRC, has conducted further evaluation and determined that the regulatory definition of emergent patient condition, in NRC's document, Yttrium-90 Microsphere Brachytherapy Sources and Devices TheraSphere and SIR-Spheres Licensing Guidance, was met. Therefore, this event is no longer classified as a "possible" medical event and the 15-day written reporting requirement of 10 CFR 35.3045(d) will not be completed."
NHPP has notified the NRC Region III Project Manager.
Notified R3DO (Peterson), R4DO (Gaddy), and NMSS Events Notification.
EN Revision Text: MEDICAL EVENT - PATIENT UNDERDOSE
The following information was provided by the licensee via phone and email:
"Per 10 CFR 35.3045(c), Veterans Health Administration (VHA) National Health Physics Program (NHPP) is reporting a possible medical event.
"Southern Arizona VA Health Care System [the facility], Tucson, Arizona, which holds Permit Number 02-06186-01 under the VA master materials license, reported discovery of a 'possible' medical event to NHPP at approximately [1500] CDT, April 19, 2023.
"A yttrium-90 microsphere therapy administration for liver cancer was performed on April 19, 2023. The intended treatment site was hepatic segment 4 of the right lobe of the liver. During the administration, performed under fluoroscopy guidance, the Authorized User (AU) / administering Interventional Radiology physician noted a change in the catheter position and elected to stop the administration. Measurements and calculations indicated the patient received about 63 percent of the prescribed activity [15.06 mCi delivered vs. 21.6 mCi prescribed]. Post implant single-photon emission computerized tomography (SPECT) imaging verified that the dosage had been delivered to the correct location.
"The AU believes that the movement of the catheter qualifies as an emergent patient condition. The written directive was modified to include the reason for not administering the intended activity, the signature of an AU for yttrium-90 microspheres, and the date signed. NHPP in coordination with the facility and NRC will conduct further evaluation of this event to determine if the regulatory definition of emergent patient condition was met.
"The patient and the referring physician have been notified.
"At this time, short term harm to the patient is not expected.
"NHPP will follow up with a written report in accordance with NRC requirements in 10 CFR 35.3045.
"NHPP has notified the NRC Region III Project Manager."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * RETRACTION FROM KIM WIEBECK TO BRIAN P. SMITH AT 1709 EDT ON 05/02/2023 * * *
The following information was provided by the licensee via email:
"Veterans Health Administration (VHA) National Health Physics Program (NHPP) placed a call to NRC Operations Center on May 2, 2023, to retract Event Number 56481 (NMED Item No. 230168).
"NHPP reported discovery of a "possible" medical event at Southern Arizona VA Health Care System, Tucson, Arizona, Permit Number 02-06186-01, on April 19, 2023.
"NHPP, in coordination with the facility and NRC, has conducted further evaluation and determined that the regulatory definition of emergent patient condition, in NRC's document, Yttrium-90 Microsphere Brachytherapy Sources and Devices TheraSphere and SIR-Spheres Licensing Guidance, was met. Therefore, this event is no longer classified as a "possible" medical event and the 15-day written reporting requirement of 10 CFR 35.3045(d) will not be completed."
NHPP has notified the NRC Region III Project Manager.
Notified R3DO (Peterson), R4DO (Gaddy), and NMSS Events Notification.
Agreement State
Event Number: 56488
Rep Org: PA Bureau of Radiation Protection
Licensee: MISTRAS Group, Inc.
Region: 1
City: Trainer State: PA
County:
License #: PA-1138
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Ernest West
Licensee: MISTRAS Group, Inc.
Region: 1
City: Trainer State: PA
County:
License #: PA-1138
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Ernest West
Notification Date: 04/26/2023
Notification Time: 08:37 [ET]
Event Date: 04/25/2023
Event Time: 00:00 [EDT]
Last Update Date: 04/26/2023
Notification Time: 08:37 [ET]
Event Date: 04/25/2023
Event Time: 00:00 [EDT]
Last Update Date: 04/26/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - DAMAGED RADIOGRAPHY CAMERA
The following information was provided by the Pennsylvania Department of Environmental Protection (the Department) via email:
"On April 25, 2023, the licensee reported damage to a QSA 880D (number D7890, source serial number 72481M), camera containing 105.8 Ci of Ir-192. While using the device shooting a 3-inch pipe positioned on a cart, the pipe fell off the cart and landed on the guide tube. The guide tube was damaged and left the source capsule in the exposed position unable to retract or to be placed back in the collimator. Lead blankets were placed on the damaged area of the guide tube. Dose rate at the established boundary was confirmed to be 0 mR/hr. The licensee staff calculated doses received to the 4 employees involved in the retrieval as 98, 310, 570, and 750 millirem. Badges have been sent to Landauer for emergency processing. The source was able to be secured safely in the device, locked in the licensee's vault, and tagged out of service. The device will be sent to the manufacturer to be inspected.
"The Department will perform a reactive inspection. More information will be provided upon receipt."
PA NMED Event Number: PA230014
The following information was provided by the Pennsylvania Department of Environmental Protection (the Department) via email:
"On April 25, 2023, the licensee reported damage to a QSA 880D (number D7890, source serial number 72481M), camera containing 105.8 Ci of Ir-192. While using the device shooting a 3-inch pipe positioned on a cart, the pipe fell off the cart and landed on the guide tube. The guide tube was damaged and left the source capsule in the exposed position unable to retract or to be placed back in the collimator. Lead blankets were placed on the damaged area of the guide tube. Dose rate at the established boundary was confirmed to be 0 mR/hr. The licensee staff calculated doses received to the 4 employees involved in the retrieval as 98, 310, 570, and 750 millirem. Badges have been sent to Landauer for emergency processing. The source was able to be secured safely in the device, locked in the licensee's vault, and tagged out of service. The device will be sent to the manufacturer to be inspected.
"The Department will perform a reactive inspection. More information will be provided upon receipt."
PA NMED Event Number: PA230014
Agreement State
Event Number: 56490
Rep Org: Georgia Radioactive Material Pgm
Licensee: Complete Cardiology
Region: 1
City: Atlanta State: GA
County:
License #: GA 1337-1
Agreement: Y
Docket:
NRC Notified By: Kaamilya Najeeullah
HQ OPS Officer: Sam Colvard
Licensee: Complete Cardiology
Region: 1
City: Atlanta State: GA
County:
License #: GA 1337-1
Agreement: Y
Docket:
NRC Notified By: Kaamilya Najeeullah
HQ OPS Officer: Sam Colvard
Notification Date: 04/26/2023
Notification Time: 14:48 [ET]
Event Date: 04/20/2023
Event Time: 00:00 [EDT]
Last Update Date: 04/26/2023
Notification Time: 14:48 [ET]
Event Date: 04/20/2023
Event Time: 00:00 [EDT]
Last Update Date: 04/26/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - LEAKING SOURCE
The information below was provided by the Georgia Department of Natural Resources via email:
"During a routine sealed source inventory and subsequent leak test performed on April 20, 2023, a physicist discovered that a Cs-137 vial source (initial calibration activity was 0.224 mCi, Cs-137, with serial number: 1710-68-15) was leaking. The source was wiped several times and counted in a Capintec CRC-55t well counter (serial number 561108) to ensure reproducibility of counts in the 662 keV window. Repeat wipe samples yielded the same counts and conclusively confirmed that the source was leaking. A picture was taken to document the visible damage of the vial. Area surveys and wipe tests performed in the location where the source was stored indicated no signs of contamination. The source has been taken out of service. As such, the leaking source has been fully contained and is currently secure in a hot lab. The licensee is currently in the process of obtaining quotes from several hazardous waste disposal companies in their region."
Georgia Radioactive Materials Program incident number: 64.
The information below was provided by the Georgia Department of Natural Resources via email:
"During a routine sealed source inventory and subsequent leak test performed on April 20, 2023, a physicist discovered that a Cs-137 vial source (initial calibration activity was 0.224 mCi, Cs-137, with serial number: 1710-68-15) was leaking. The source was wiped several times and counted in a Capintec CRC-55t well counter (serial number 561108) to ensure reproducibility of counts in the 662 keV window. Repeat wipe samples yielded the same counts and conclusively confirmed that the source was leaking. A picture was taken to document the visible damage of the vial. Area surveys and wipe tests performed in the location where the source was stored indicated no signs of contamination. The source has been taken out of service. As such, the leaking source has been fully contained and is currently secure in a hot lab. The licensee is currently in the process of obtaining quotes from several hazardous waste disposal companies in their region."
Georgia Radioactive Materials Program incident number: 64.
Agreement State
Event Number: 56492
Rep Org: Louisiana Radiation Protection Div
Licensee: Acuren Inspection Inc
Region: 4
City: Baton Rouge State: LA
County:
License #: LA-7072-L01, Amdt. 129, AI# 126755
Agreement: Y
Docket:
NRC Notified By: Richard Blackwell
HQ OPS Officer: Thomas Herrity
Licensee: Acuren Inspection Inc
Region: 4
City: Baton Rouge State: LA
County:
License #: LA-7072-L01, Amdt. 129, AI# 126755
Agreement: Y
Docket:
NRC Notified By: Richard Blackwell
HQ OPS Officer: Thomas Herrity
Notification Date: 04/26/2023
Notification Time: 17:15 [ET]
Event Date: 12/31/2022
Event Time: 00:00 [CDT]
Last Update Date: 04/26/2023
Notification Time: 17:15 [ET]
Event Date: 12/31/2022
Event Time: 00:00 [CDT]
Last Update Date: 04/26/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - POSSIBLE OVEREXPOSURE TO RADIOGRAPHER
The following information was provided by the LA Department of Environmental Quality (the Department) via email:
"[The Department] was notified by Acuren Inspection Radiation Safety Officer (RSO) via the Department radiation hotline at approximately 1400 [CDT] on April 26, 2023, concerning a possible excessive exposure. According to the RSO, a radiographer that has been working in Pennsylvania had his December badge come back with a dose of 8000 mrem. The December badge was sent to Landauer with the March badges and the reading was just received by Acuren. The RSO states that the radiographer works in the dark room processing film and leaves his badge in his bag with other tools. The radiographer believes his bag was used by someone else while performing industrial radiography and that is how the badge got exposed. Acuren will be performing an investigation."
LA event report ID No.: LA 20230007
The following information was provided by the LA Department of Environmental Quality (the Department) via email:
"[The Department] was notified by Acuren Inspection Radiation Safety Officer (RSO) via the Department radiation hotline at approximately 1400 [CDT] on April 26, 2023, concerning a possible excessive exposure. According to the RSO, a radiographer that has been working in Pennsylvania had his December badge come back with a dose of 8000 mrem. The December badge was sent to Landauer with the March badges and the reading was just received by Acuren. The RSO states that the radiographer works in the dark room processing film and leaves his badge in his bag with other tools. The radiographer believes his bag was used by someone else while performing industrial radiography and that is how the badge got exposed. Acuren will be performing an investigation."
LA event report ID No.: LA 20230007
Power Reactor
Event Number: 56497
Facility: Vogtle 3/4
Region: 2 State: GA
Unit: [3] [] []
RX Type: [3] W-AP1000,[4] W-AP1000
NRC Notified By: Chad Everitt
HQ OPS Officer: Sam Colvard
Region: 2 State: GA
Unit: [3] [] []
RX Type: [3] W-AP1000,[4] W-AP1000
NRC Notified By: Chad Everitt
HQ OPS Officer: Sam Colvard
Notification Date: 05/02/2023
Notification Time: 07:57 [ET]
Event Date: 05/02/2023
Event Time: 04:23 [EDT]
Last Update Date: 05/02/2023
Notification Time: 07:57 [ET]
Event Date: 05/02/2023
Event Time: 04:23 [EDT]
Last Update Date: 05/02/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Miller, Mark (R2DO)
Miller, Mark (R2DO)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
3 | M/R | Y | 14 | Power Operation | 0 | Hot Standby |
MANUAL REACTOR TRIP
The following information was provided by the licensee via email:
"At 0423 EDT on 05/02/2023, with Unit 3 in Mode 1 at 14 percent power, the reactor was manually tripped due to securing all main feed pumps, due to sudden high differential pressure on their suction strainers. The trip was not complex, with all safety-related systems responding normally post-trip. No equipment was inoperable prior to the event that contributed to the event or adversely impacted plant response to the reactor trip.
"Operations responded and stabilized the plant. Decay heat is being removed by discharging steam to the main condenser using the steam dumps, and startup feedwater is supplying the steam generators. Units 1, 2, and 4 were not affected.
"Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
The following information was provided by the licensee via email:
"At 0423 EDT on 05/02/2023, with Unit 3 in Mode 1 at 14 percent power, the reactor was manually tripped due to securing all main feed pumps, due to sudden high differential pressure on their suction strainers. The trip was not complex, with all safety-related systems responding normally post-trip. No equipment was inoperable prior to the event that contributed to the event or adversely impacted plant response to the reactor trip.
"Operations responded and stabilized the plant. Decay heat is being removed by discharging steam to the main condenser using the steam dumps, and startup feedwater is supplying the steam generators. Units 1, 2, and 4 were not affected.
"Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
Power Reactor
Event Number: 56501
Facility: Palisades
Region: 3 State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: Jeffrey Lewis
HQ OPS Officer: Brian P. Smith
Region: 3 State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: Jeffrey Lewis
HQ OPS Officer: Brian P. Smith
Notification Date: 05/02/2023
Notification Time: 22:41 [ET]
Event Date: 05/02/2023
Event Time: 15:00 [EDT]
Last Update Date: 05/02/2023
Notification Time: 22:41 [ET]
Event Date: 05/02/2023
Event Time: 15:00 [EDT]
Last Update Date: 05/02/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(xiii) - Loss Comm/Asmt/Response
10 CFR Section:
50.72(b)(3)(xiii) - Loss Comm/Asmt/Response
Person (Organization):
Peterson, Hironori (R3DO)
Peterson, Hironori (R3DO)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
1 | N | N | 0 | Defueled | 0 | Defueled |
LOSS OF COMMUNICATIONS
The following information was provided by the licensee via email:
"At approximately 1500 [EST] on 5/2/2023, it was determined that the commercial telecommunications capacity was lost to the Palisades Nuclear Plant (PNP) control room and technical support center due to an issue with the telecommunications provider. After discovery of the condition it was discovered that this loss also included the emergency notification system (ENS). Communications link via the satellite phone was tested satisfactorly. In addition, if needed, the satellite phone would be used to initiate call-out of the emergency response organization. The condition did not affect the ENS or commercial telecommunications capabilities at the offsite Emergency Operations Facility. The telecommunications provider has not provided an estimated repair time."
PNP will be notifying the NRC resident inspector.
The following information was provided by the licensee via email:
"At approximately 1500 [EST] on 5/2/2023, it was determined that the commercial telecommunications capacity was lost to the Palisades Nuclear Plant (PNP) control room and technical support center due to an issue with the telecommunications provider. After discovery of the condition it was discovered that this loss also included the emergency notification system (ENS). Communications link via the satellite phone was tested satisfactorly. In addition, if needed, the satellite phone would be used to initiate call-out of the emergency response organization. The condition did not affect the ENS or commercial telecommunications capabilities at the offsite Emergency Operations Facility. The telecommunications provider has not provided an estimated repair time."
PNP will be notifying the NRC resident inspector.