Event Notification Report for April 12, 2023

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/11/2023 - 04/12/2023

EVENT NUMBERS
56454564605646456456
Agreement State
Event Number: 56454
Rep Org: Kentucky Dept of Radiation Control
Licensee: Big Rivers Electric Corporation
Region: 1
City: Centertown   State: KY
County: Ohio
License #: 201-277-56
Agreement: Y
Docket:
NRC Notified By: Dr. Curt Pendergrass
HQ OPS Officer: Dan Livermore
Notification Date: 04/05/2023
Notification Time: 11:51 [ET]
Event Date: 04/04/2023
Event Time: 00:00 [CDT]
Last Update Date: 04/06/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Gray, Mel (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK SHUTTER

The following is a summary of information provided by the Kentucky Department of Radiation Control via email:

On April 4, 2023, an authorized gauge user identified a shutter stuck open on a gauge mounted 15 feet up in the air on a coal feeder at the D.B. Wilson power plant. The shutter opened and closed; however, when the shutter was placed into a closed position some radiation exposure was still present outside the shutter. The gauge is model number 7062BP, serial number 17777, with 100 mCi Cs-137. The Radiation Safety Officer (RSO) alerted employees of the stuck shutter. The gauge will remain in place until a certified contractor can remove it. The contractor is expected to arrive on April 5, 2023.

* * * UPDATE ON 4/6/2023 AT 1254 EDT FROM CURT PENDERGRASS TO IAN HOWARD * * *

The following information was provided by the Kentucky Department of Radiation Control via email:

"According to the RSO, RAM Services, Inc. was able to free up the shutter yesterday, but there were issues with elevated exposure rates so the decision was made to dispose of the device and package it for shipping."

Notified R1DO (Gray) and NMSS Events Notification.


Power Reactor
Event Number: 56460
Facility: Vogtle 3/4
Region: 2     State: GA
Unit: [3] [] []
RX Type: [3] W-AP1000,[4] W-AP1000
NRC Notified By: Tommie Sweat
HQ OPS Officer: Adam Koziol
Notification Date: 04/10/2023
Notification Time: 04:34 [ET]
Event Date: 04/10/2023
Event Time: 00:48 [EDT]
Last Update Date: 04/10/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Miller, Mark (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 A/R Y 18 Power Operation 0 Hot Standby
Event Text
AUTOMATIC REACTOR TRIP

The following information was provided by the licensee via email:

"At 0048 EDT on 4/10/2023, with Unit 3 in Mode 1 at 18 percent power, the reactor automatically tripped due to low reactor coolant flow due to voltage decaying to the reactor coolant pumps during main generator testing activities. The trip was not complex, with all safety-related systems responding normally post-trip.

"Operations responded and stabilized the plant. Decay heat is being removed by discharging steam via steam generator power operated relief valves to atmosphere. Units 1, 2, and 4 are not affected.

"Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B).

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 56464
Facility: Limerick
Region: 1     State: PA
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: Tim Gallacher
HQ OPS Officer: Sam Colvard
Notification Date: 04/11/2023
Notification Time: 11:05 [ET]
Event Date: 02/16/2023
Event Time: 08:05 [EDT]
Last Update Date: 04/11/2023
Emergency Class: Non Emergency
10 CFR Section:
50.73(a)(1) - Invalid Specif System Actuation Other Unspec Reqmnt
Person (Organization):
Lilliendahl, Jon (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
60 DAY NOTIFICATION FOR AN INVALID ACTUATION OF THE EMERGENCY SERVICE WATER SYSTEM

The following information was provided by the licensee via email:

"This 60-day telephone notification is being made per the reporting requirements specified by 10 CFR 50.73(a)(2)(iv)(A) and 10 CFR 50.73(a)(1) to describe an invalid specific system actuation of the Emergency Service Water (ESW) System.

"On 2/16/2023, while performing a calibration planned maintenance (PM) for a jacket water pressure indicator during a D13 diesel generator system outage window, the 'C' ESW pump unexpectedly auto-started. Subsequent investigation identified that the affected jacket water pressure indicator shares a common sensing line with a jacket water pressure switch that provides a back-up to the engine speed switch for the engine running signal. At the time the jacket water pressure indicator calibration PM was being performed, the power circuits for D13 diesel generator instrumentation were energized. Pressurization of the energized jacket water pressure switch during the pressure indicator calibration activity resulted in initiation of a false engine running signal to the `C' ESW pump start logic.

"This event is considered an invalid system actuation because the 'C' ESW pump started in response to a false signal that the D13 EDG was running when the D13 EDG did not start. The actuation was not initiated in response to actual plant conditions or parameters and was not a manual initiation. The ESW system functioned as expected in response to the actuation. The affected ESW pump was shut down in accordance with plant procedures. There was no impact on the health and safety of the public or plant personnel."

The licensee notified the NRC Resident Inspector.


Agreement State
Event Number: 56456
Rep Org: California Radiation Control Prgm
Licensee: PEI, Inc.
Region: 4
City: San Leandro   State: CA
County:
License #: 8323-34
Agreement: Y
Docket:
NRC Notified By: Robert Greger
HQ OPS Officer: Ian Howard
Notification Date: 04/06/2023
Notification Time: 22:41 [ET]
Event Date: 04/05/2023
Event Time: 19:00 [PDT]
Last Update Date: 04/06/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Warnick, Greg (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSNS (Mexico), - (EMAIL) (EMAIL)
Event Text
AGREEMENT STATE REPORT - STOLEN NUCLEAR GAUGES

The following was received from the California Department of Public Health, Radiologic Health Branch (CARHB) via email:

"On April 6, 2023, California Office of Emergency Services was notified by a Pavement Engineering, Inc. (PEI) Radiation Safety Officer that two nuclear gauges (Troxler Model 3430, S/N 75597 and Troxler Model 4640-B, S/N 1930 each containing 9 mCi of Cs-137 and the former containing 40 mCi of Am-241) were stolen from a company vehicle, on April 5, 2023, around 1900 [PDT], that was parked at a taqueria located in San Leandro, CA. Both gauges were reported by PEI to have been properly secured/locked in the bed of a company truck.

"The licensee notified the San Leandro Police Department of the stolen gauges and CARHB will notify the FBI.

"CARHB will be investigating the circumstances of the theft."

California NMED Number: 040623

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf