Event Number: 56434
Facility: Susquehanna
Region: 1     State: PA
Unit: [2] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: Robert Bingman
HQ OPS Officer: Eric Simpson
Notification Date: 03/26/2023
Notification Time: 19:41 [ET]
Event Date: 03/26/2023
Event Time: 16:03 [EDT]
Last Update Date: 03/26/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
Person (Organization):
Werkheiser, Dave (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
DEGRADED CONDITION - LEAK RATE LIMITS EXCEEDED
The following information was provided by the licensee via email:
"On 03/26/2023 at 1603 EDT, while performing Appendix J local leak rate testing, it was determined that the Secondary Containment Bypass Leakage (SCBL) limit had been exceeded for Unit 2. During performance of the leak rate test, SE-259-027 for X-9B penetration, it was determined that the combined SCBL limit of 15 standard cubic feet per hour for the as-found minimum pathway was exceeded, as specified in Technical Specification, Surveillance Requirement 3.6.1.3.11.
"This event is being reported pursuant to 10CFR50.72(b)(3)(ii).
"The Resident Inspector has been notified."