Event Notification Report for February 19, 2023

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/18/2023 - 02/19/2023

EVENT NUMBERS
56373
Power Reactor
Event Number: 56373
Facility: FitzPatrick
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Michael Lewis
HQ OPS Officer: Eric Simpson
Notification Date: 02/19/2023
Notification Time: 08:56 [ET]
Event Date: 02/19/2023
Event Time: 01:05 [EST]
Last Update Date: 02/19/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Dentel, Glenn (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
SPECIFIED SYSTEM ACTUATION
The following information was provided by the licensee via fax or email:
"At 0105 EST on February 19, 2023, with the James A. FitzPatrick Nuclear Power Plant (JAF) at 100 percent power, a valid high main steam line radiation signal was received. An actuation of a fire protection foam system caused migration of high conductivity water into a low conductivity sump. Organic compounds were introduced into the primary coolant and resulted in a temporary increase in nitrogen-16 which was detected by main steam line radiation monitors and actuated primary containment isolation signals in more than one system. The reactor water recirculation sample system isolated. The signal also went to the normally isolated main steam line drain system and condenser air removal system. The event is reportable in accordance with 10 CFR 50.72(b)(3)(iv)(A). The elevated radiation condition no longer exists. Health and safety of the public was not impacted by this event."

The NRC Resident Inspector was notified.