Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for January 25, 2023

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/24/2023 - 01/25/2023

Agreement State
Event Number: 56034
Rep Org: MA Radiation Control Program
Licensee: PETNET Solutions
Region: 1
City: Woburn   State: MA
County:
License #: 42-0650
Agreement: Y
Docket:
NRC Notified By: Tony Carpenito
HQ OPS Officer: Mike Stafford
Notification Date: 08/05/2022
Notification Time: 16:56 [ET]
Event Date: 08/05/2022
Event Time: 00:00 [EDT]
Last Update Date: 01/24/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
EN Revision Imported Date: 1/25/2023

EN Revision Text: AGREEMENT STATE REPORT - POTENTIAL OVEREXPOSURE TO EXTREMITY

The following information was received from the Massachusetts Radiation Control Program (the Agency) via email:

"Licensee reported employee weekly finger ring exposure exceeding 50 rem (67.569 rem for wear period, 7/4/22-7/10/22) a situation reportable within 24 hours per 105 CMR 120.282 (B) (1) (c). The other finger ring dosimeter worn by the subject employee received 31.509 rem exposure for same wear period. Exact cause of exposure not yet known. Licensee investigation ongoing. Licensee, a radiopharmaceutical manufacturer/distributer, stated that subject employee does perform work involved with F-18 radiopharmaceutical manufacturing operations.

"The Agency considers this matter still open."

MA Event Number: 20-5102

* * * UPDATE ON 1/24/23 AT 1054 EST FROM BOB LOCKE TO ADAM KOZIOL * * *

"On August 17, 2022, An Agency investigation was performed at the PETNET facility. The inspector determined that the root cause of the event was insufficient training of staff. The licensee submitted sufficient corrective actions to prevent recurrence. The Massachusetts Radiation Control Program considers this incident closed."

Notified R1DO (DeFrancisco) and NMSS (email).


Agreement State
Event Number: 56226
Rep Org: MA Radiation Control Program
Licensee: Spiegel South Shore Scrap Metal Inc. (Non-licensed)
Region: 1
City: Everett   State: MA
County:
License #: N/A
Agreement: Y
Docket:
NRC Notified By: Robert Locke
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 11/17/2022
Notification Time: 11:30 [ET]
Event Date: 11/01/2022
Event Time: 09:00 [EST]
Last Update Date: 01/24/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Dimitriadis, Anthony (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
EN Revision Imported Date: 1/25/2023

EN Revision Text: AGREEMENT STATE REPORT - Ra-226 DISC FOUND IN SCRAP LOAD

The following information was provided by the Massachusetts Radiation Control Program (the Agency) via email:

"On 11/1/2022, Schnitzer Steel [Docket 23-5219] in Everett, MA notified the Agency that portal monitors detected radioactive contamination in a scrap load that originated from Spiegel Scrap Metal in Brockton. A handheld meter measurement showed 0.03 mR/hr on the driver's side of the truck. DOT [Department of Transportation] exemption form MA-MA 22-28 was created to transport the load back to Spiegel Scrap Metal.

"On 11/3/2022, Atlantic Nuclear surveyed the contents of the scrap load and discovered a disc containing Ra-226. A handheld meter measured 1.5 mR/hr on contact. The estimated activity of the gauge is 2 microCuries. Spiegel is contracting Chase Environmental to dispose of the item.

"The reporting requirement is within 30 days and is of 105 CMR 120.281(A)(2), missing licensed radioactive materials in aggregate quantity equal to or greater than 10 times quantity specified in 105 CMR 120.297, Appendix C.

"The Agency considers this event to be open."

* * * UPDATE ON 1/24/23 AT 1055 EST FROM BOB LOCKE TO ADAM KOZIOL * * *

"The disc had no identifying markings such as manufacturer name, model number and serial number. The Ra-226 disc is currently in storage at the Spiegel facility scheduled for eventual transfer to a licensed disposal service. Probable inadvertent disposal by unknown person or persons at an unknown time in the past."

Notified R1DO (DeFrancisco) and NMSS (email).


Agreement State
Event Number: 56312
Rep Org: Arizona Dept of Health Services
Licensee: HonorHealth Shea
Region: 4
City: Scottsdale   State: AZ
County:
License #: 07-265
Agreement: Y
Docket:
NRC Notified By: Brian D. Goretzki
HQ OPS Officer: Lloyd Desotell
Notification Date: 01/18/2023
Notification Time: 13:34 [ET]
Event Date: 09/30/2022
Event Time: 00:00 [MST]
Last Update Date: 01/18/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Josey, Jeffrey (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - PATIENT UNDERDOSE

The following information was provided by the Arizona Department of Health Services (the Department) via email:

"The Department identified a possible medical event involving Y-90 Sir-Spheres during a routine inspection. A patient was prescribed an activity of 0.05 GBq (1.45 mCi) but was delivered 0.02 GBq (0.53 mCi), a percent dose delivered of 36.55 percent. The procedure date was 9/30/2022. The Department has requested additional information and continues to investigate the event."

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 56314
Rep Org: Texas Dept of State Health Services
Licensee: Precision NDT LLC
Region: 4
City: Odessa   State: TX
County:
License #: L 07054
Agreement: Y
Docket:
NRC Notified By: Arthur Tucker
HQ OPS Officer: Brian P. Smith
Notification Date: 01/18/2023
Notification Time: 16:37 [ET]
Event Date: 01/18/2023
Event Time: 00:00 [CST]
Last Update Date: 01/18/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Josey, Jeffrey (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - UNABLE TO RETRACT SOURCE INTO FULLY RETRACTED POSITION

The following report was received via email from the Texas Department of State Services [the Agency]:

"On January 18, 2023, the Agency was notified by the licensee that one of its radiography crews [working in Midland, TX] was unable to retract a 99.0 curie iridium - 192 [Ir-192] source into the fully retracted and locked position in a QSA 880D exposure device. The licensee stated they were able to retract the source into the exposure device, but it would not lock in the fully retracted position. An individual on the license approved to recover sources went to the site to retract the source. The licensee contacted the manufacturer who was able to provide instructions to the field team on how to return the source to the locked position. The licensee reported no overexposure occurred due to this event. Additional information will be provided as it is received in accordance with SA-300."

Texas Incident No: I-9981
Texas NMED No.: TX230002


Agreement State
Event Number: 56315
Rep Org: OR Dept of Health Rad Protection
Licensee: The Wallace Group
Region: 4
City: Bend   State: OR
County:
License #: 91125
Agreement: Y
Docket:
NRC Notified By: Hillary Haskins
HQ OPS Officer: Lloyd Desotell
Notification Date: 01/18/2023
Notification Time: 18:13 [ET]
Event Date: 01/18/2023
Event Time: 14:49 [PST]
Last Update Date: 01/18/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Josey, Jeffrey (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - DAMAGED TROXLER GAUGE

The following is a summary of information provided by the Oregon Health Authority, Radiation Protection Services via email and phone:

The licensee reported a damaged Troxler 3430 portable moisture density gauge. The gauge's cover was found to be cracked in multiple places, including the electronic pad. The source is in the shielded position and readings around the gauge indicate that the shielding is intact. It is unclear how the gauge became damaged but was found near a vibrating plate compactor.

The gauge will be shipped to the manufacturer for repair once a leak test has been performed.

Dose readings at 3 feet from source: 0.12-0.16 mR/hr
Gauge source: 8 mCi Cs-137, 40 mCi Am-241:Be
Oregon Emergency Response System Incident Number: 2023-0140


Power Reactor
Event Number: 56321
Facility: Browns Ferry
Region: 2     State: AL
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: Eric Steele
HQ OPS Officer: Adam Koziol
Notification Date: 01/24/2023
Notification Time: 08:43 [ET]
Event Date: 01/24/2023
Event Time: 01:21 [CST]
Last Update Date: 01/24/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
Miller, Mark (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
EN Revision Imported Date: 1/25/2023

EN Revision Text: HIGH PRESSURE COOLANT INJECTION INOPERABLE

The following information was provided by the licensee via email:

"At 0121 CST on 01/24/2023, it was discovered that the Unit 1 High Pressure Coolant Injection System (HPCI) was inoperable; therefore, the condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v), as an event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to mitigate the consequences of an accident.

"1-FCV-073-0006B, HPCI Steam Line Condensate Outboard Drain Valve, failed closed during normal plant configuration. This valve is normally open. The HPCI steam line is not being drained with the valve in the current position.

"The Unit 1 Nuclear Unit Senior Operator entered Unit 1 Technical Specifications LCO 3.5.1 Condition C with required actions C.1 to immediately verify by administrative means that the Reactor Core Isolation Cooling (RCIC) system is operable and C.2 to restore HPCI to operable status in 14 days. RCIC has been verified operable by administrative means.

"There was no impact to the safety of the public or plant personnel. The NRC Resident Inspector has been notified."


Agreement State
Event Number: 56317
Rep Org: WA Office of Radiation Protection
Licensee: MultiCare Health System
Region: 4
City: Tacoma   State: WA
County:
License #: WN-M017-1
Agreement: Y
Docket:
NRC Notified By: Boris G. Tsenov
HQ OPS Officer: Lloyd Desotell
Notification Date: 01/19/2023
Notification Time: 18:33 [ET]
Event Date: 01/18/2023
Event Time: 00:00 [PST]
Last Update Date: 01/19/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Josey, Jeffrey (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - PATIENT UNDERDOSE

The following is a summary of information provided by the Washington State Department of Health (DOH), Radioactive Materials Section via email:

The licensee reported that a Y-90 TheraSphere liver treatment was completed in accordance with manufacturer requirements and nothing out of the ordinary was observed. However, during a subsequent step to flush the system with saline, the technician, who is not an authorized user or radioactive material user, noticed bubbles coming up above the vial. Wipe samples of the procedure equipment were counted and showed radioactivity. A second flush of the system was initiated but the same bubbles were observed and therefore the flush was stopped, and the catheter was retracted from the patient. Additional flushes were not attempted. An evaluation showed that the patient received only 33 percent of the intended dose. The activity contained in the wipes and cleaning materials accounted for the balance of the intended dose (66 percent) and was disposed of as waste. DOH has requested additional information regarding potential occupational exposures. The licensee will submit a detailed report.

Washington Incident Number: WA-23-003.

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 56322
Facility: Sequoyah
Region: 2     State: TN
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Jeffery Blaine
HQ OPS Officer: Ian Howard
Notification Date: 01/25/2023
Notification Time: 13:22 [ET]
Event Date: 05/23/2022
Event Time: 00:00 [EST]
Last Update Date: 01/25/2023
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Miller, Mark (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
PART 21 - MEDIUM VOLTAGE CIRCUIT BREAKERS

The following information is a synopsis of information provided by the licensee via fax and phone:

On May 23, 2022, Framatome informed Tennessee Valley Authority (TVA) of a deviation of breakers purchased under contract. On January 23, 2023, TVA determined that a defect of the basic component could create a substantial safety hazard.

Framatome Inc. identified a deviation in the Siemens medium voltage vacuum circuit breaker where a failure to electrically charge or electrically close could occur. Framatome Inc. identified this as a departure from the technical requirements included in the procurement document. It is noted that the ability to electrically trip the circuit breaker would not be affected by the condition. TVA was notified by Framatome under 10 CFR 21.21(b) to evaluate the application of the breaker for a substantial safety hazard.

The TVA evaluation identified these breakers as intended for use in safety related Class 1E applications where a loss of the closure function would impact mitigation of design basis accidents and transients. During the Framatome dedication testing/inspection of Siemens medium voltage vacuum breakers, a hi-pot test failure on one circuit breaker was encountered. Troubleshooting and inspection found damage to charging motor wiring. It was determined that the cause of the damage was due to the manner in which control wiring was routed and connected to the internal bracket in close proximity to a bracket edge. This edge caused damage to wiring after significant number of cycles were applied to the breaker prior to dedication testing.

TVA received nine medium voltage vacuum circuit breakers at an offsite warehouse facility. While located at that facility, TVA, with assistance from Framatome, examined the affected breakers for the wire routing condition. The wiring harnesses of certain breakers were corrected. Framatome is to examine medium voltage vacuum circuit breakers that may be purchased under this contract for the wiring condition and correct as necessary before delivery.

The NRC Senior Resident Inspector has been notified.

This is a non-emergency notification required by 10 CFR 21.21(d)(3)(i).