Event Notification Report for December 13, 2022

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/12/2022 - 12/13/2022

Agreement State
Event Number: 56234
Rep Org: SC Dept of Health & Env Control
Licensee: Mead & Hunt, Inc.
Region: 1
City: West Columbia   State: SC
County:
License #: 840
Agreement: Y
Docket:
NRC Notified By: Adam Gause
HQ OPS Officer: Ernest West
Notification Date: 11/18/2022
Notification Time: 17:12 [ET]
Event Date: 11/18/2022
Event Time: 10:24 [EST]
Last Update Date: 12/12/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Dimitriadis, Anthony (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
EN Revision Imported Date: 12/13/2022

EN Revision Text: AGREEMENT STATE REPORT - DAMAGED TROXLER GAUGE

The following information was provided by the South Carolina Department of Health and Environmental Control (The Department) via email:

"The Department was notified on 11/18/22 at 1243 EST via telephone that a Troxler 3400 series portable moisture density gauge, serial number 33556, had been hit by a piece of construction equipment.

"The Troxler 3400 series portable moisture density gauge contains a maximum activity of 9 millicuries of Cs-137 and 44 millicuries of Am-241:Be. The licensee reported the source rod had been dislodged but had been successfully inserted back into the shielded position. A Department inspector was dispatched to the location on 11/18/22 and assisted the licensee in packing the damaged Troxler 3400 series device into the transport container. Dose rate readings using a ND-2000A survey instrument, calibrated 09/16/22 indicated readings as high as 30 mR/hr on the surface of the transport container and less than 1 mR/hr at 1 meter.

"The Troxler 3400 series moisture density gauge was transported and secured at the licensee's storage location and is awaiting shipment back to the manufacturer. This event is still under investigation by the South Carolina Department of Health and Environmental Control."

* * * UPDATE ON 12/12/2022 AT 1052 EST FROM ADAM GAUSE TO BRIAN LIN * * *

The following information was provided by the South Carolina Department of Health and Environmental Control (The Department) via email:

"The licensee submitted a written report, dated 11/28/22, outlining the event details and findings. The licensee did not indicate overexposure to any individuals. Records indicate the damaged gauge was not leaking and that the gauge/sources have been transferred to the manufacturer for disposal. This event is considered closed."

Notified R1DO (Henrion) and NMSS Events Notification email group.


Agreement State
Event Number: 56259
Rep Org: Texas Dept of State Health Services
Licensee: Pro Inspection Incorporated
Region: 4
City: Odessa   State: TX
County:
License #: L 06666
Agreement: Y
Docket:
NRC Notified By: Chris Moore
HQ OPS Officer: Adam Koziol
Notification Date: 12/05/2022
Notification Time: 14:57 [ET]
Event Date: 12/05/2022
Event Time: 00:00 [CST]
Last Update Date: 12/05/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
O'Keefe, Neil (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - RADIOGRAPHY CAMERA MALFUNCTION

The following information was provided by the Texas Department of State Health Services via email:

"On December 5, 2022, the licensee reported that an equipment malfunction occurred with a Source Production & Equipment Company, Inc. (SPEC) 150 Radiography Camera, serial number 1524, containing 66 curies of Iridium-192. They were testing the camera in the office because the technician reported it started to hang up several times when retrieving the source and disconnecting the crank cables. The camera was tested and the source was retrieved but they were unable to disconnect the crank cables. They had to cut the locking device, remove the cables, and install a plug. The camera and cables are being transported to a service company for inspection and repair. No additional radiation exposure occurred from the incident. SPEC source serial number DI2710. Additional information will be provided in accordance with SA 300."

Texas Incident No.: I - 9969


Agreement State
Event Number: 56260
Rep Org: Colorado Dept of Health
Licensee: LDS Church - Denver-Monaco
Region: 4
City: Denver   State: CO
County:
License #: GL000718
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Adam Koziol
Notification Date: 12/06/2022
Notification Time: 12:02 [ET]
Event Date: 07/16/2020
Event Time: 00:00 [MST]
Last Update Date: 12/06/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
O'Keefe, Neil (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST EXIT SIGNS

The following information was provided by the Colorado Department of Public Health and Environment via email:

The licensee discovered twelve tritium exit signs were lost. The exit signs are SRB Technologies Model BR20BK containing 20 Ci of tritium (H-3) each. This is being reported under Colorado Regulations Section 4.51.1.1 (10 CFR 20.2202(a)(1)(i)).

Colorado Incident No.: CO220043

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Non-Agreement State
Event Number: 56262
Rep Org: Kakivic Asset Management
Licensee: Kakivic Asset Management
Region: 4
City: Prudhoe Bay   State: AK
County:
License #: 50-27667-01
Agreement: N
Docket:
NRC Notified By: Marty Anderson
HQ OPS Officer: Thomas Herrity
Notification Date: 12/06/2022
Notification Time: 12:05 [ET]
Event Date: 12/06/2022
Event Time: 02:00 [YST]
Last Update Date: 12/06/2022
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
O'Keefe, Neil (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
DAMAGED RADIOGRAPHIC CAMERA

The following information was provided by the licensee via email:

"At 0200 YST on December 06, 2022, the radiation safety supervisor (RSS) received a call that the technicians had a source which refused to retract to the safe and secured position. During the exposure, the camera fell approximately 4 feet to the ground and landed on the guide tube, which then didn't allow the source to be returned to a shielded position. The radiographers on site followed their procedure and secured their boundaries and notified the RSS. Two RSSs arrived on site at 0245 YST and were able to safely return the source back to locked position. At 1000 YST, a third RSS arrived on location to assist in retrieval.

"The source that required retrieval was IR-192 at 80.6 curies in a Type B container/special form."


Power Reactor
Event Number: 56269
Facility: Wolf Creek
Region: 4     State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Jason Knust
HQ OPS Officer: Brian Lin
Notification Date: 12/12/2022
Notification Time: 11:05 [ET]
Event Date: 10/13/2022
Event Time: 16:48 [CST]
Last Update Date: 12/12/2022
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Drake, James (R4DO)
Part 21/50.55 Reactors, - (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Defueled 100 Power Operation
Event Text
PART 21 - INADEQUATE TORQUE VALUES

The following information was provided by the licensee via email:

"On October 13, 2022, during Refueling Outage 25, 2 bolts and 2 washers were discovered in the strainer basket upstream of the main steam stop valve in the steam line from the 'A' steam generator. It was determined that these bolts and washers were from the main steam isolation valve (MSIV) upstream of the stop valve. One bolt and one washer were also determined to be missing from the MSIV on the line from the 'B' steam generator. The MSIVs are a similar design as the Main Feedwater Isolation Valves (MFIVs). It appears that the torque values for these backseat bolts provided by the vendor weren't sufficient to prevent the bolts from coming loose. Wolf Creek Nuclear Operating Corporation personnel evaluated the condition and determined that the inadequate torque values provided by the vendor could have constituted a substantial safety hazard if left uncorrected. In particular, if bolts had come loose from the MFIVs, they could have traveled downstream to the steam generators and then challenged the integrity of steam generator tubes.

"The NRC Senior Resident Inspector has been notified.

"This is a non-emergency notification required by 10 CFR 21.21(d)(3)(i).

"A written notification will be provided within 30 days."


Power Reactor
Event Number: 56153
Facility: Braidwood
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Vincent Roddy
HQ OPS Officer: Ian Howard
Notification Date: 10/07/2022
Notification Time: 08:35 [ET]
Event Date: 10/07/2022
Event Time: 01:19 [CDT]
Last Update Date: 12/13/2022
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
Person (Organization):
Betancourt-Roldan, Diana (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
EN Revision Imported Date: 12/14/2022

EN Revision Text: CONTROL ROD DRIVE MECHANISM (CRDM) PENETRATION DEGRADED

The following information was provided by the licensee via fax:

"Control Rod Drive Mechanism (CRDM) penetration 69 degraded.

"At 0119 [CDT] on October 7, 2022, it was determined that the CRDM penetration 69 was degraded because examination identified unacceptable indications in accordance with ASME Code Case N-729-6. Therefore, this event is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(ii)(A).

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."

* * * UPDATE ON 12/13/22 AT 1825 EST FROM KRYSTIAN JARONCZYK TO ADAM KOZIOL * * *

"The notification is being corrected to state:

"At 0119 [CDT] on October 7, 2022, it was determined that the Control Rod Drive Mechanism (CRDM) penetration 69 was degraded because liquid penetrant testing, performed on the seal weld, identified unacceptable indications in accordance with ASME Section III and NRC approved licensee relief request for a previously performed embedded flaw repair. Therefore, this event is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(ii)(A).

"There was no impact on the health and safety of the public or plant personnel."

Notified R3DO (Ruiz).


Agreement State
Event Number: 56255
Rep Org: Georgia Radioactive Material Pgm
Licensee: Construction Materials Services
Region: 1
City: Locust Grove   State: GA
County:
License #: GA 1392-1
Agreement: Y
Docket:
NRC Notified By: Shatavia Grimes
HQ OPS Officer: Bill Gott
Notification Date: 12/02/2022
Notification Time: 14:51 [ET]
Event Date: 12/02/2022
Event Time: 00:00 [EST]
Last Update Date: 12/13/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
Event Text
EN Revision Imported Date: 12/14/2022

EN Revision Text: AGREEMENT STATE REPORT - LOST GAUGE

The following information was provided by the Georgia Radioactive Material Program via email:

"[The] gauge was placed on the tailgate of a truck by a technician at the Eastman Airport and not secured in the box. It fell out within 4 miles of last use in the city limits of Eastman, Dodge County. The licensee will be contacted for more detailed information. The Georgia Radioactive Material Program will update this report as more information comes in. "

Georgia Incident No.: 62

* * * UPDATE ON 12/13/2022 AT 0813 EST FROM THE GEORGIA RADIOACTIVE MATERIALS PROGRAM TO IAN HOWARD * * *

The following information was provided by the Georgia Radioactive Materials Program via email:

"The Radiation Safety Officer (RSO) stated he informed the local police authority of the lost gauge, and for them to be on the lookout. This is the second incident with the employee and more action will be taken. The RSO and the team went out to look for the gauge today and were unsuccessful in locating it. Upon receipt, we will update this report as more information comes available."

Notified: R1DO (Henrion). Notified via email: NMSS Event Notification and ILTAB.

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 56263
Rep Org: NE Div of Radioactive Materials
Licensee: Hilltop 4 Theatres
Region: 4
City: Kearney   State: NE
County:
License #: GL0202
Agreement: Y
Docket:
NRC Notified By: Deb Wilson
HQ OPS Officer: Nestor Makris
Notification Date: 12/07/2022
Notification Time: 11:02 [ET]
Event Date: 12/06/2022
Event Time: 00:00 [CST]
Last Update Date: 12/07/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
O'Keefe, Neil (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST EXIT SIGNS

The following information was provided by the Nebraska Dept. of Health and Human Services via email:

The licensee discovered two tritium exit signs were lost. The exit signs are Isolite model SLX60 containing 7.5 Ci of tritium (H-3) each. This is being reported under 10 CFR 20.2202(a)(1)(i).

Nebraska Incident No.: NE220006

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pd