Event Notification Report for March 10, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/09/2021 - 03/10/2021
Agreement State
Event Number: 54853
Rep Org: WA OFFICE OF RADIATION PROTECTION
Licensee: Framatome Inc.
Region: 4
City: Richland State: WA
County:
License #: I062
Agreement: Y
Docket:
NRC Notified By: Andrew Halloran
HQ OPS Officer: Thomas Kendzia
Licensee: Framatome Inc.
Region: 4
City: Richland State: WA
County:
License #: I062
Agreement: Y
Docket:
NRC Notified By: Andrew Halloran
HQ OPS Officer: Thomas Kendzia
Notification Date: 08/24/2020
Notification Time: 00:00 [ET]
Event Date: 08/17/2020
Event Time: 00:00 [PDT]
Last Update Date: 03/09/2021
Notification Time: 00:00 [ET]
Event Date: 08/17/2020
Event Time: 00:00 [PDT]
Last Update Date: 03/09/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
RAY KELLAR (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
RAY KELLAR (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 3/10/2021
EN Revision Text: AGREEMENT STATE REPORT - LEAKING CHECK SOURCE
The following was received from the State of Washington via email:
"Framatome notified the State of Washington of a leaking 5 microCi Cs-137 check source that was identified on 8/17/2020. A set of stack samples showed evidence of Cs-137 contamination, leading the Radiation Safety Officer for the licensee to contact the Radiological Safety Supervisor to investigate into the possibility of a leaking Cs-137 check source. A visibly damaged source was identified and a leak test of the source revealed 0.02 microCi of removable material. The source storage area was surveyed to determine if there was any additional contamination, but none above the licensee's limits for action was identified. The source was contained and placed in storage to be held for disposal."
Washington Incident No.: WA-20-017
* * * UPDATE ON AUGUST 26, 2020 AT 1250 EDT FROM ANDREW HALLORAN TO BRIAN LIN * * *
The following information was received from the State of Washington via email:
"The leak test was performed in accordance with approved procedures using an instrument that was appropriate and in calibration. The source was part of a source jig used for routine instrument checks around the site. According to the Radiation Safety Officer, the source was likely damaged from impact against a hard surface during routine use."
Notified R4DO (Kellar) and NMSS Events Notification (email).
* * * UPDATE ON MARCH 9, 2021 AT 1838 EST FROM ANDREW HALLORAN TO BRIAN LIN * * *
The following information was received from the State of Washington via email:
"The source has been removed from service to be sent for disposal with the next waste shipment. Source manufacturer - The Nucleus. Serial number - SB-D14. Activity - 5 microCi."
Notified R4DO (Josey) and NMSS Events Notification (email).
EN Revision Text: AGREEMENT STATE REPORT - LEAKING CHECK SOURCE
The following was received from the State of Washington via email:
"Framatome notified the State of Washington of a leaking 5 microCi Cs-137 check source that was identified on 8/17/2020. A set of stack samples showed evidence of Cs-137 contamination, leading the Radiation Safety Officer for the licensee to contact the Radiological Safety Supervisor to investigate into the possibility of a leaking Cs-137 check source. A visibly damaged source was identified and a leak test of the source revealed 0.02 microCi of removable material. The source storage area was surveyed to determine if there was any additional contamination, but none above the licensee's limits for action was identified. The source was contained and placed in storage to be held for disposal."
Washington Incident No.: WA-20-017
* * * UPDATE ON AUGUST 26, 2020 AT 1250 EDT FROM ANDREW HALLORAN TO BRIAN LIN * * *
The following information was received from the State of Washington via email:
"The leak test was performed in accordance with approved procedures using an instrument that was appropriate and in calibration. The source was part of a source jig used for routine instrument checks around the site. According to the Radiation Safety Officer, the source was likely damaged from impact against a hard surface during routine use."
Notified R4DO (Kellar) and NMSS Events Notification (email).
* * * UPDATE ON MARCH 9, 2021 AT 1838 EST FROM ANDREW HALLORAN TO BRIAN LIN * * *
The following information was received from the State of Washington via email:
"The source has been removed from service to be sent for disposal with the next waste shipment. Source manufacturer - The Nucleus. Serial number - SB-D14. Activity - 5 microCi."
Notified R4DO (Josey) and NMSS Events Notification (email).
Agreement State
Event Number: 55119
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: QSA Global, Inc.
Region: 1
City: Burlington State: MA
County:
License #: 12-8361
Agreement: Y
Docket:
NRC Notified By: Robert Locke
HQ OPS Officer: Donald Norwood
Licensee: QSA Global, Inc.
Region: 1
City: Burlington State: MA
County:
License #: 12-8361
Agreement: Y
Docket:
NRC Notified By: Robert Locke
HQ OPS Officer: Donald Norwood
Notification Date: 03/01/2021
Notification Time: 16:31 [ET]
Event Date: 03/01/2021
Event Time: 14:00 [EST]
Last Update Date: 03/05/2021
Notification Time: 16:31 [ET]
Event Date: 03/01/2021
Event Time: 14:00 [EST]
Last Update Date: 03/05/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
ELISE BURKET (R1DO)
SILAS KENNEDY (IR)
REBECCA RICHARDSON (ILTAB)
THERESA CLARK (NMSS)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ELISE BURKET (R1DO)
SILAS KENNEDY (IR)
REBECCA RICHARDSON (ILTAB)
THERESA CLARK (NMSS)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 3/8/2021
EN Revision Text: AGREEMENT STATE REPORT - CATEGORY 2 PACKAGE CONTAINING SEVEN SEALED SOURCES LOST IN TRANSIT
"The licensee reported to the Agency [Massachusetts Radiation Control Program] at 1400 EST on March 1, 2021, that it discovered on March 1, 2021 at 1200 EST that a package (Yellow-III, T.I. 2.6, Type B, UN 2916) containing seven sealed sources (Ir-192; 59.9 Ci, 59.2 Ci, 58.1 Ci, 59.9 Ci, 59.5 Ci, 59.8 Ci, and 69.2 Ci) in a model 976C source changer was missing.
"The package was shipped by QSA Global, Inc. on February 12, 2021, for export to their customer NDT Instruments, based in Singapore. On March 1, 2021 at 1200 EST, QSA Global, Inc. discovered that the package had not been received.
"The carrier indicated that the package had been at their Memphis, TN facility on 2/13/2021, and that since then the location is unknown.
"The reporting requirement is immediate and is of 105 CMR 120.281(A)(1), missing licensed radioactive materials in aggregate quantity equal to or greater than 1,000 times the quantity specified in 105 CMR 120.297, Appendix C. The four-hour reporting requirement of 105 CMR 120.077(B), missing shipment of Category 2 quantity of radioactive material, also applies."
The Agency considers this event to be open.
Notified: DHS-SWO, FEMA-OC, USDA-OC, HHS-OC, DOE-OC, DHS CISA Central, and EPA-EOC, Notified via E-mail: FDA- EOC, Nuclear SSA, FEMA-NWC, and CWMD-Watch Desk.
* * * UPDATE ON 3/5/2021 AT 1534 EST FROM ROBERT LOCKE TO JOANNA BRIDGE * * *
The following was received via e-mail from the Radiation Control Officer, Massachusetts Radiation Control Program:
"Licensee reports that they were notified on [5 March, 2021] that the missing package had been located in Memphis. The package was found undamaged and will continue for export to Singapore."
Notified R1DO (BURKET), NMSS (RIVERA-CAPELLA), IR MOC (GOTT), and ILTAB (RICHARDSON) and via email NMSS EVENTS NOTIFICATION, and INES NATIONAL OFFICER (MILLIGAN). Also notified DHS-SWO, FEMA-OC, USDA-OC, HHS-OC, DOE-OC, DHS CISA Central, and EPA-EOC and via email FDA- EOC, Nuclear SSA, FEMA-NWC, and CWMD-Watch Desk.
THIS MATERIAL EVENT CONTAINS A "CATEGORY 2" LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - CATEGORY 2 PACKAGE CONTAINING SEVEN SEALED SOURCES LOST IN TRANSIT
"The licensee reported to the Agency [Massachusetts Radiation Control Program] at 1400 EST on March 1, 2021, that it discovered on March 1, 2021 at 1200 EST that a package (Yellow-III, T.I. 2.6, Type B, UN 2916) containing seven sealed sources (Ir-192; 59.9 Ci, 59.2 Ci, 58.1 Ci, 59.9 Ci, 59.5 Ci, 59.8 Ci, and 69.2 Ci) in a model 976C source changer was missing.
"The package was shipped by QSA Global, Inc. on February 12, 2021, for export to their customer NDT Instruments, based in Singapore. On March 1, 2021 at 1200 EST, QSA Global, Inc. discovered that the package had not been received.
"The carrier indicated that the package had been at their Memphis, TN facility on 2/13/2021, and that since then the location is unknown.
"The reporting requirement is immediate and is of 105 CMR 120.281(A)(1), missing licensed radioactive materials in aggregate quantity equal to or greater than 1,000 times the quantity specified in 105 CMR 120.297, Appendix C. The four-hour reporting requirement of 105 CMR 120.077(B), missing shipment of Category 2 quantity of radioactive material, also applies."
The Agency considers this event to be open.
Notified: DHS-SWO, FEMA-OC, USDA-OC, HHS-OC, DOE-OC, DHS CISA Central, and EPA-EOC, Notified via E-mail: FDA- EOC, Nuclear SSA, FEMA-NWC, and CWMD-Watch Desk.
* * * UPDATE ON 3/5/2021 AT 1534 EST FROM ROBERT LOCKE TO JOANNA BRIDGE * * *
The following was received via e-mail from the Radiation Control Officer, Massachusetts Radiation Control Program:
"Licensee reports that they were notified on [5 March, 2021] that the missing package had been located in Memphis. The package was found undamaged and will continue for export to Singapore."
Notified R1DO (BURKET), NMSS (RIVERA-CAPELLA), IR MOC (GOTT), and ILTAB (RICHARDSON) and via email NMSS EVENTS NOTIFICATION, and INES NATIONAL OFFICER (MILLIGAN). Also notified DHS-SWO, FEMA-OC, USDA-OC, HHS-OC, DOE-OC, DHS CISA Central, and EPA-EOC and via email FDA- EOC, Nuclear SSA, FEMA-NWC, and CWMD-Watch Desk.
THIS MATERIAL EVENT CONTAINS A "CATEGORY 2" LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55121
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: AESCO Technologies, Inc.
Region: 4
City: Huntington Beach State: CA
County:
License #: 7197-30
Agreement: Y
Docket:
NRC Notified By: L. Robert Greger
HQ OPS Officer: Ossy Font
Licensee: AESCO Technologies, Inc.
Region: 4
City: Huntington Beach State: CA
County:
License #: 7197-30
Agreement: Y
Docket:
NRC Notified By: L. Robert Greger
HQ OPS Officer: Ossy Font
Notification Date: 03/03/2021
Notification Time: 20:18 [ET]
Event Date: 03/03/2021
Event Time: 04:30 [PST]
Last Update Date: 03/03/2021
Notification Time: 20:18 [ET]
Event Date: 03/03/2021
Event Time: 04:30 [PST]
Last Update Date: 03/03/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
GROOM, JEREMY (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
GROOM, JEREMY (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
AGREEMENT STATE REPORT - LOST AND FOUND GAUGE
The following is a summary of a report received from the California Department of Public Health (the Department) via email:
The Department was notified that a Troxler model 3440, Serial Number 22188 (9 mCi. Cs-137, 44 mCi. Am:Be-241) had been lost when the operator left the worksite believing the gauge was in the bed of the truck. At approximately 1430 PST, the licensee reported the gauge had been located at the work site and returned. The licensee is investigating the event and the Department will review their findings.
California Report ID: 5010-030321
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of a report received from the California Department of Public Health (the Department) via email:
The Department was notified that a Troxler model 3440, Serial Number 22188 (9 mCi. Cs-137, 44 mCi. Am:Be-241) had been lost when the operator left the worksite believing the gauge was in the bed of the truck. At approximately 1430 PST, the licensee reported the gauge had been located at the work site and returned. The licensee is investigating the event and the Department will review their findings.
California Report ID: 5010-030321
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 55128
Facility: Susquehanna
Region: 1 State: PA
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: Darvin Duttry
HQ OPS Officer: Bethany Cecere
Region: 1 State: PA
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: Darvin Duttry
HQ OPS Officer: Bethany Cecere
Notification Date: 03/09/2021
Notification Time: 08:08 [ET]
Event Date: 03/09/2021
Event Time: 03:13 [EST]
Last Update Date: 03/09/2021
Notification Time: 08:08 [ET]
Event Date: 03/09/2021
Event Time: 03:13 [EST]
Last Update Date: 03/09/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
GRAY, MEL (R1)
GRAY, MEL (R1)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
1 | N | Y | 100 | Power Operation | 100 | Power Operation |
HIGH PRESSURE COOLANT INJECTION INOPERABLE
"At 0313 EST on March 9th, 2021, during performance of Unit 1 High Pressure Coolant Injection (HPCI) valve exercising, the inboard vacuum breaker isolation valve did not stroke closed as expected, but remained mid-position. The affected penetration of primary containment was isolated by closing the outboard HPCI vacuum breaker isolation valve. This results in an unplanned inoperability of the Unit 1 HPCI system.
"This is being reported as a loss of an entire safety function condition in accordance with 10CFR50.72(b)(3)(v)(D).
The licensee notified the NRC Resident Inspector.
Unit 1 is in a 14-day LCO for Tech Spec 3.5.1(d), HPCI inoperability. Tech Spec 3.6.1.3(a), Containment Penetration Valve, was completed with closing the outboard HPCI vacuum breaker isolation valve. The Units are in a normal offsite power line-up.
"At 0313 EST on March 9th, 2021, during performance of Unit 1 High Pressure Coolant Injection (HPCI) valve exercising, the inboard vacuum breaker isolation valve did not stroke closed as expected, but remained mid-position. The affected penetration of primary containment was isolated by closing the outboard HPCI vacuum breaker isolation valve. This results in an unplanned inoperability of the Unit 1 HPCI system.
"This is being reported as a loss of an entire safety function condition in accordance with 10CFR50.72(b)(3)(v)(D).
The licensee notified the NRC Resident Inspector.
Unit 1 is in a 14-day LCO for Tech Spec 3.5.1(d), HPCI inoperability. Tech Spec 3.6.1.3(a), Containment Penetration Valve, was completed with closing the outboard HPCI vacuum breaker isolation valve. The Units are in a normal offsite power line-up.
Non-Power Reactor
Event Number: 55129
Rep Org: Texas A&M University
Licensee: Texas A&M University
Region: 0
City: College Station State: TX
County: Brazos
License #: R-83
Agreement: Y
Docket: 05000128
NRC Notified By: Sean McDeavitt
HQ OPS Officer: Bethany Cecere
Licensee: Texas A&M University
Region: 0
City: College Station State: TX
County: Brazos
License #: R-83
Agreement: Y
Docket: 05000128
NRC Notified By: Sean McDeavitt
HQ OPS Officer: Bethany Cecere
Notification Date: 03/09/2021
Notification Time: 11:22 [ET]
Event Date: 03/08/2021
Event Time: 10:27 [CST]
Last Update Date: 03/09/2021
Notification Time: 11:22 [ET]
Event Date: 03/08/2021
Event Time: 10:27 [CST]
Last Update Date: 03/09/2021
Emergency Class: Non Emergency
10 CFR Section:
10 CFR Section:
Person (Organization):
Patrick Boyle (NRR PM)
Michael Takacs (NRR ENC)
Patrick Boyle (NRR PM)
Michael Takacs (NRR ENC)
SUSPECTED TECH SPEC POWER LIMIT EXCEEDED
At 1027 CST on 3/8/21, while the reactor was at 900 kW at steady state, a sample was pulled before the planned down power was executed. As a result, the reactor may have exceeded the 1000 kW limit for one second by 1 kW per Tech Spec 3.1. The duration was recorded on the strip chart recorder.
The licensee has notified the NRC Project Manager (Patrick Boyle).
At 1027 CST on 3/8/21, while the reactor was at 900 kW at steady state, a sample was pulled before the planned down power was executed. As a result, the reactor may have exceeded the 1000 kW limit for one second by 1 kW per Tech Spec 3.1. The duration was recorded on the strip chart recorder.
The licensee has notified the NRC Project Manager (Patrick Boyle).
Power Reactor
Event Number: 55130
Facility: Sequoyah
Region: 2 State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Ryan Radel
HQ OPS Officer: Brian Lin
Region: 2 State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Ryan Radel
HQ OPS Officer: Brian Lin
Notification Date: 03/09/2021
Notification Time: 11:58 [ET]
Event Date: 01/11/2021
Event Time: 11:52 [EST]
Last Update Date: 03/09/2021
Notification Time: 11:58 [ET]
Event Date: 01/11/2021
Event Time: 11:52 [EST]
Last Update Date: 03/09/2021
Emergency Class: Non Emergency
10 CFR Section:
50.73(a)(1) - Invalid Specif System Actuation
10 CFR Section:
50.73(a)(1) - Invalid Specif System Actuation
Person (Organization):
MILLER, MARK (R2)
MILLER, MARK (R2)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
1 | N | Y | 100 | Power Operation | 100 | Power Operation |
60-DAY OPTIONAL TELEPHONIC NOTIFICATION FOR INVALID CONTAINMENT VENTILATION ISOLATION ACTUATION
"This 60-day telephone notification is being submitted in accordance with 10 CFR 50.73(a)(1) and 50.73(a)(2)(iv)(A). The event was an invalid actuation of the Unit 1 Containment Ventilation Isolation (CVI) system.
"On January 11, 2021 at 1152 Eastern Standard Time (EST) with Unit 1 at 100% power, Train 'A' of the CVI System actuated due to an invalid high radiation signal from 1-RM-90-130, Containment Purge Air Exhaust Monitor. The cause of the signal was determined to be a failed sample pump associated with the radiation monitor. 1-RM-90-130 was in service at the time of the invalid signal. The Train 'A' Containment Ventilation Isolation signal was a full actuation of that train and the system functioned as designed.
"Prior to and following the invalid high radiation alarms, all radiation monitors except 1-RM-90-130 were stable at their normal values; therefore, the CVI was invalid. Control room operators performed appropriate checks and confirmed that all required automatic actuations occurred as designed. The failed pump was replaced and returned to service. This event was entered into the corrective action program as CR 1663398.
"The NRC Resident Inspector was notified."
"This 60-day telephone notification is being submitted in accordance with 10 CFR 50.73(a)(1) and 50.73(a)(2)(iv)(A). The event was an invalid actuation of the Unit 1 Containment Ventilation Isolation (CVI) system.
"On January 11, 2021 at 1152 Eastern Standard Time (EST) with Unit 1 at 100% power, Train 'A' of the CVI System actuated due to an invalid high radiation signal from 1-RM-90-130, Containment Purge Air Exhaust Monitor. The cause of the signal was determined to be a failed sample pump associated with the radiation monitor. 1-RM-90-130 was in service at the time of the invalid signal. The Train 'A' Containment Ventilation Isolation signal was a full actuation of that train and the system functioned as designed.
"Prior to and following the invalid high radiation alarms, all radiation monitors except 1-RM-90-130 were stable at their normal values; therefore, the CVI was invalid. Control room operators performed appropriate checks and confirmed that all required automatic actuations occurred as designed. The failed pump was replaced and returned to service. This event was entered into the corrective action program as CR 1663398.
"The NRC Resident Inspector was notified."
Agreement State
Event Number: 55123
Rep Org: IOWA DEPARTMENT OF PUBLIC HEALTH
Licensee: University of Iowa
Region: 3
City: Iowa City State: IA
County:
License #: 0037152AAB
Agreement: Y
Docket:
NRC Notified By: Randal S. Dahlin
HQ OPS Officer: Ossy Font
Licensee: University of Iowa
Region: 3
City: Iowa City State: IA
County:
License #: 0037152AAB
Agreement: Y
Docket:
NRC Notified By: Randal S. Dahlin
HQ OPS Officer: Ossy Font
Notification Date: 03/04/2021
Notification Time: 12:06 [ET]
Event Date: 02/03/2021
Event Time: 00:00 [CST]
Last Update Date: 03/04/2021
Notification Time: 12:06 [ET]
Event Date: 02/03/2021
Event Time: 00:00 [CST]
Last Update Date: 03/04/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
HILLS, DAVID (R3)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
HILLS, DAVID (R3)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
AGREEMENT STATE REPORT - LOST P-32 SHIPMENT
The following was received from Iowa Department of Public Health via email:
"On February 3, 2021, the University of Iowa received a package from [the common carrier] that was labeled as one of the standing orders of 1 millicurie P-32 dCTP for the Pathology Lab at UIHC [(University of Iowa Health Care)]. The outer label was correct and the packing slip inside was correct, however the contents of the package was actually a prescription of Enbrel intended for an individual in Illinois.
Further, the contents had obviously been repacked. It arrived in a large [common carrier] box, much bigger than required for the P-32 order or the Enbrel. Also, the top of the original package that held the P-32 had been torn off and affixed to the replacement box in an adhesive pouch. The licensee contacted both [the common carrier] and the pharmaceutical company that shipped the Enbrel. [The common carrier] returned to retrieve the Enbrel but haven't heard anything about the location of the original P-32 order. Perkin Elmer sent a replacement shipment of P-32 to the licensee. On February 10, 2021, [the common carrier] sent an email to the licensee notifying them that the original shipment of P-32 has not been located and they were closing the case. On March 4, 2021, the Iowa Department of Public Health contacted the University of Iowa Radiation Safety Officer (RSO) and was informed by the RSO that the original shipment of P-32 is still missing. The activity of the P-32 as of March 4, 2021 is approximately 244 microcuries."
Item Number: IA210001
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following was received from Iowa Department of Public Health via email:
"On February 3, 2021, the University of Iowa received a package from [the common carrier] that was labeled as one of the standing orders of 1 millicurie P-32 dCTP for the Pathology Lab at UIHC [(University of Iowa Health Care)]. The outer label was correct and the packing slip inside was correct, however the contents of the package was actually a prescription of Enbrel intended for an individual in Illinois.
Further, the contents had obviously been repacked. It arrived in a large [common carrier] box, much bigger than required for the P-32 order or the Enbrel. Also, the top of the original package that held the P-32 had been torn off and affixed to the replacement box in an adhesive pouch. The licensee contacted both [the common carrier] and the pharmaceutical company that shipped the Enbrel. [The common carrier] returned to retrieve the Enbrel but haven't heard anything about the location of the original P-32 order. Perkin Elmer sent a replacement shipment of P-32 to the licensee. On February 10, 2021, [the common carrier] sent an email to the licensee notifying them that the original shipment of P-32 has not been located and they were closing the case. On March 4, 2021, the Iowa Department of Public Health contacted the University of Iowa Radiation Safety Officer (RSO) and was informed by the RSO that the original shipment of P-32 is still missing. The activity of the P-32 as of March 4, 2021 is approximately 244 microcuries."
Item Number: IA210001
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 55132
Facility: Quad Cities
Region: 3 State: IL
Unit: [1] [2] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: Derek Drockelman
HQ OPS Officer: Brian Lin
Region: 3 State: IL
Unit: [1] [2] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: Derek Drockelman
HQ OPS Officer: Brian Lin
Notification Date: 03/10/2021
Notification Time: 18:26 [ET]
Event Date: 03/10/2021
Event Time: 16:23 [CST]
Last Update Date: 03/10/2021
Notification Time: 18:26 [ET]
Event Date: 03/10/2021
Event Time: 16:23 [CST]
Last Update Date: 03/10/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
KOZAK, LAURA (R3)
KOZAK, LAURA (R3)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
1 | N | Y | 85 | Power Operation | 85 | Power Operation |
2 | N | Y | 100 | Power Operation | 100 | Power Operation |
NOTIFICATION OF ENVIRONMENTAL REPORT TO ANOTHER GOVERNMENT AGENCY
"On March 10, 2021, Exelon reported an unpermitted release of a radionuclide (i.e., tritium) into the groundwater within the site boundary at Quad Cities Nuclear Power Station to the Illinois Environmental Protection Agency (IEPA) and the Illinois Emergency Management Agency (IEMA) in accordance with Illinois state regulations. There has been no detection of the release beyond the site boundary. The suspected source for the increased groundwater tritium levels is an onsite water storage tank or pipe; however, an investigation is in progress and the exact cause and source is not yet known. The increase in groundwater tritium concentration does not exceed any NRC regulations or reporting criteria. This notification is being made solely as a four-hour, non-emergency notification for a Notification of Other Government Agency.
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
"On March 10, 2021, Exelon reported an unpermitted release of a radionuclide (i.e., tritium) into the groundwater within the site boundary at Quad Cities Nuclear Power Station to the Illinois Environmental Protection Agency (IEPA) and the Illinois Emergency Management Agency (IEMA) in accordance with Illinois state regulations. There has been no detection of the release beyond the site boundary. The suspected source for the increased groundwater tritium levels is an onsite water storage tank or pipe; however, an investigation is in progress and the exact cause and source is not yet known. The increase in groundwater tritium concentration does not exceed any NRC regulations or reporting criteria. This notification is being made solely as a four-hour, non-emergency notification for a Notification of Other Government Agency.
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."