Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for January 15, 2020

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
1/14/2020 - 1/15/2020

** EVENT NUMBERS **

 

54464 54476

Agreement State Event Number: 54464
Rep Org: COLORADO DEPT OF HEALTH
Licensee: DBI, INC
Region: 4
City: KERSEY   State: CO
County:
License #: CO 1247-01
Agreement: Y
Docket:
NRC Notified By: PHILLIP PETERSON
HQ OPS Officer: BRIAN LIN
Notification Date: 01/07/2020
Notification Time: 13:11 [ET]
Event Date: 01/07/2020
Event Time: 00:00 [MST]
Last Update Date: 01/07/2020
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
HEATHER GEPFORD (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)

Event Text

AGREEMENT STATE REPORT - SOURCE DISCONNECT

The following was received from the State of Colorado via email:

"On January 7, 2020, DBI, Inc. reported a source disconnect for an industrial radiography source. The disconnect occurred on the first exposure of the day. The radiographer and assistant extended their boundaries and were able to restrict access at the location. The radiation safety officer was contacted and was successfully able to recover the source into a shielded container. The industrial radiography device was a QSA 880 delta and the source was an Ir-192 source with approximately 42 Curies.

"An onsite investigation will be scheduled in the future."

Event Report ID No.: CO200001

Part 21 Event Number: 54476
Rep Org: UNITED CONTROLS INTERNATIONAL
Licensee: UNITED CONTROLS INTERNATIONAL
Region: 1
City: NORCROSS   State: GA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: ROB HALE
HQ OPS Officer: ANDREW WAUGH
Notification Date: 01/14/2020
Notification Time: 10:37 [ET]
Event Date: 12/27/2019
Event Time: 00:00 [EST]
Last Update Date: 01/14/2020
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21(d)(3)(i) - DEFECTS AND NONCOMPLIANCE
Person (Organization):
JAMIE HEISSERER (R2DO)
- PART 21/50.55 REACTORS (EMAIL)

Event Text

PART 21 - INCORRECT TIP MATERIAL USED ON GAUGES

On December 27, 2019, United Controls International received a Product Advisory Letter from Ashcroft Inc. dated December 2, 2019 informing of a potential error in the tip material used on Ashcroft 2 « inch and 3 « inch model 1009, 63 mm model 2008, 63 mm and 100 mm model 1008 industrial gauges along with Weksler 3 « inch regal gauges. Due to a supplier issue, 304SS tip material may have been supplied on the subject gauges instead of the specified 316SS material. In certain applications the 304SS tip material may be subject to accelerated oxidation or degradation, resulting in potential release of process media. However, no detrimental effects are expected in non-corrosive applications.

Hatch and Farley have been identified as the affected plants and have been notified of this issue.

Please contact Wesley Hickle, Engineering Manager, at (770) 496-1406 ext. 165 or whickle@unitedcontrols.com for any questions.

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021