Event Notification Report for December 21, 2017
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/20/2017 - 12/21/2017 ** EVENT NUMBERS ** | | Power Reactor | Event Number: 53132 | Facility: WATTS BAR Region: 2 State: TN Unit: [1] [2] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: JUSTIN GALLAGHER HQ OPS Officer: VINCE KLCO | Notification Date: 12/20/2017 Notification Time: 18:18 [ET] Event Date: 12/20/2017 Event Time: 10:40 [EST] Last Update Date: 12/20/2017 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION | Person (Organization): ERIC MICHEL (R2DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text SYSTEM ACTUATIONS DUE TO OPENING OF FEEDER BREAKER TO SHUTDOWN BOARD "On December 20, 2017, at 1040 Eastern Standard Time (EST), the Watts Bar Nuclear Plant (WBN) 1B-B 6.9kV Shutdown Board (SDBD) normal feeder breaker opened. The loss of voltage to the 1B-B SDBD resulted in the start of the 1B-B Motor Driven Auxiliary Feedwater (MDAFW) pump, the Unit 1 Turbine Driven Auxiliary Feedwater (TDAFW) pump, and the start of all four Emergency Diesel Generators (EDGs). Power was restored to the 1B-B 6.9 kV SDBD when it loaded on to its associated EDG. "Following initial investigation, the 1B-B 6.9 kV SDBD was transferred to its alternate offsite power source, Common Station Service Transformer (CSST) C at 1217 EST. At 1230 EST, the 1B-B 6.9 kV SDBD alternate feeder breaker opened. The loss of voltage to the 1B-B SDBD did not result in the restart of the 1B MDAFW pump, the Unit 1 TDAFW pump, or EDGs; this equipment remained running from the earlier event. Power was restored to the 1B-B 6.9 kV SDBD when it loaded on to its associated EDG. "Restoration of normal offsite power to the 1B-B SDBD was completed at 1654. "Other than several common Unit Technical Specifications having not been met, Unit 2 was not operationally impacted by the transfer of the 1B-B Shutdown Board to onsite power and remains in Mode 1 at 100% power. "This report is made per 10 CFR 50.72(b)(3)(iv)(A). "NRC Resident Inspector has been notified." The licensee investigation continues for the cause of the event. | | Power Reactor | Event Number: 53133 | Facility: COOPER Region: 4 State: NE Unit: [1] [ ] [ ] RX Type: [1] GE-4 NRC Notified By: TERRELL HIGGINS HQ OPS Officer: MARK ABRAMOVITZ | Notification Date: 12/20/2017 Notification Time: 21:22 [ET] Event Date: 12/20/2017 Event Time: 15:59 [CST] Last Update Date: 12/20/2017 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): GREG PICK (R4DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text EMERGENCY ALERT SYSTEM OUT OF SERVICE "During review of the documentation for the 11/16/17 outage of the NOAA/NWS [National Oceanographic and Atmospheric Administration/National Weather Service] tower, it was identified that there was also record of a trouble ticket being issued on 11/19/17 for the NOAA/NWS tower. Further discussions with the National Weather Service determined that the tower did experience an outage on 11/19/17 which affected the ability to activate EAS [Emergency Alert System]/Tone Alert Radios. Final determination that the EAS/Tone Alert Radios were affected during this outage was made at 1559 [CST], which was the time that the National Weather Service sent the e-mail to the EP [Emergency Planning] Manager and EP Offsite Coordinator with notification that activation of the EAS/Tone Alert Radios was affected during the outage. This is considered to be a major loss of the Public Prompt Notification System capability, and is reportable under 10CFR 50.72(b)(3)(xiii). "The transmission outage was on 11/19/2017 0853 until 1100 but CNS [Cooper Nuclear Station] was not notified until 1559 on 12/20/2017. "The NRC Senior Resident has been informed" | |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021