Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for July 11, 2017

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
07/10/2017 - 07/11/2017

** EVENT NUMBERS **


52838 52843 52844 52845

To top of page
Agreement State Event Number: 52838
Rep Org: SC DIV OF HEALTH & ENV CONTROL
Licensee: CLEMSON UNIVERSITY
Region: 1
City: CLEMSON State: SC
County:
License #: 540
Agreement: Y
Docket:
NRC Notified By: ANDREW M. ROXBURGH
HQ OPS Officer: DONG HWA PARK
Notification Date: 07/03/2017
Notification Time: 11:22 [ET]
Event Date: 12/12/2013
Event Time: [EDT]
Last Update Date: 07/03/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
RAY POWELL (R1DO)
NMSS_EVENTS_NOTIFICA (EMAI)

Event Text

AGREEMENT STATE REPORT - UNPLANNED CONTAMINATION

The following report was received from the South Carolina Department of Health and Environmental Control via e-mail:

"This event was first reported to the State as an allegation but is now being reported as an incident because of our recent IMPEP [Integrated Materials Performance Evaluation Program] review.

"The unplanned contamination was because of the dissolution of a Po-210 Static Eliminator containing 125 microcuries. The contamination was discovered when a Graduate Research Assistance was surveying himself upon exiting the lab. The RSO was notified and the lab was thoroughly decontaminated. The laboratory was posted and access was restricted. The licensee was required to report this incident within 24 hours of discovery because the unplanned contamination caused a restricted area to be closed for more than 24 hours."

To top of page
Power Reactor Event Number: 52843
Facility: GRAND GULF
Region: 4 State: MS
Unit: [1] [ ] [ ]
RX Type: [1] GE-6
NRC Notified By: DAVID BURRUS
HQ OPS Officer: BETHANY CECERE
Notification Date: 07/10/2017
Notification Time: 05:42 [ET]
Event Date: 07/09/2017
Event Time: 21:58 [CDT]
Last Update Date: 07/10/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
THOMAS FARNHOLTZ (R4DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation

Event Text

LOSS OF SAFETY FUNCTION - CONTROL ROOM ENVELOPE INOPERABLE

"At 2158 [CDT] a door to the Control Room Envelope was left unsecure. GGNS [Grand Gulf Nuclear Station] identified that a loss of Safety Function occurred due to a breach in the Control Room Envelope resulting in inoperability of both divisions of Standby Fresh Air and therefore could have prevented fulfillment of its safety function. The Control Room Envelope was inoperable for one minute. This event is being reported under 10CFR 50.72(b)(3)(v)(D), as any event or condition that, at the time of discovery, could have prevented the fulfillment of the safety function of structures or systems that are needed to mitigate the consequences of an accident."

The licensee notified the NRC Resident Inspector.

To top of page
Power Reactor Event Number: 52844
Facility: SUSQUEHANNA
Region: 1 State: PA
Unit: [1] [2] [ ]
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: STEVEN KOCH
HQ OPS Officer: STEVE SANDIN
Notification Date: 07/10/2017
Notification Time: 07:35 [ET]
Event Date: 07/10/2017
Event Time: 02:50 [EDT]
Last Update Date: 07/10/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
Person (Organization):
ANTHONY DIMITRIADIS (R1DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation

Event Text

LOSS OF SECONDARY CONTAINMENT DUE TO FAILURE OF NON-SAFETY RELATED DISCHARGE DAMPER

"On July 10th, 2017 at 0250 hrs. [EDT] a loss of secondary containment differential pressure (D/P) occurred due to failure of a non-safety related discharge damper associated with 2V205B Reactor Building Zone II Exhaust Fan. This caused a reduction in Reactor Building Zone II (Unit 2) D/P to less than the required 0.25 inches WC [Water Column].

"2V205A Reactor Building Zone II Exhaust Fan was manually started and Reactor Building Zone II D/P was restored to greater than 0.25 inches WC by 0301 hrs.

"Reactor Building Zone 1 (Unit 1) and Zone 3 (Units 1&2) ventilation remained in service and stable.

"This event is being reported under 10 CFR 50.72(b)(3)(v)(c) and per the guidance of NUREG 1022, Rev. 3, section 3.2.7 as a loss of a Safety Function. There is no redundant Susquehanna Secondary Containment system."

The licensee notified the NRC Resident Inspector.

To top of page
Power Reactor Event Number: 52845
Facility: BRUNSWICK
Region: 2 State: NC
Unit: [1] [2] [ ]
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: BRUCE LEITCH
HQ OPS Officer: JEFF HERRERA
Notification Date: 07/10/2017
Notification Time: 19:26 [ET]
Event Date: 07/10/2017
Event Time: 16:02 [EDT]
Last Update Date: 07/10/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
JAMIE HEISSERER (R2DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation

Event Text

OFFSITE NOTIFICATION DUE TO CONTRACT EMPLOYEE FATALITY

"At approximately 14:10 Eastern Daylight Time (EDT), the Control Room was notified of a contract employee experiencing a non-work related medical emergency within the protected area in the service building. First responders were immediately dispatched. Off-site assistance was requested. The individual was transported to the New Hanover Regional Medical Center. No radioactive material or contamination was involved. At 16:02 EDT, hospital officials notified plant personnel that the patient was declared deceased.

"This notification is being made in accordance with 10 CFR 50.72(b)(2)(xi) for a situation related to the health of on-site personnel for which a notification to other government agencies is planned. The Occupational Safety and Health Administration (OSHA) will be notified.

"The NRC Resident Inspector has been notified."

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021