Event Notification Report for April 1, 2010
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 03/31/2010 - 04/01/2010 ** EVENT NUMBERS ** | General Information or Other | Event Number: 45788 | Rep Org: MINNESOTA DEPARTMENT OF HEALTH Licensee: MAYO CLINIC Region: 3 City: ROCHESTER State: MN County: OLMSTED License #: 1047-205-55 Agreement: Y Docket: NRC Notified By: GEORGE JOHNS HQ OPS Officer: VINCE KLCO | Notification Date: 03/25/2010 Notification Time: 15:27 [ET] Event Date: 03/23/2010 Event Time: [CDT] Last Update Date: 03/25/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): LAURA KOZAK (R3DO) ANDREA KOCK (FSME) | Event Text AGREEMENT STATE REPORT - IMPROPER DOSAGE GIVEN DURING MEDICAL TREATMENT The following information was received by e-mail: "On March 25, 2010, Mayo Clinic notified the Minnesota Department of Health of an HDR [High Dose Rate After Loader] medical event. The patient was prescribed four fractions of 4 Gy for a biliary HDR treatment. The catheter had been placed and imaged. A dummy source was pushed into the catheter until it met resistance that was assumed to be the end of the catheter. In fact, the resistance was a tight bend approximately 17 centimeters (6.69 inches) short of the end. "The distance that was thought to be the end of the catheter was incorrectly used for the treatment distance and the patient was subsequently treated. Prior to treatment the following day, a dummy source was again inserted. That source extended beyond the programmed distance. An x-ray revealed that the end of the catheter was beyond the initial treatment location. "For the first two fractions, the HDR source was 17 cm from its intended treatment location. This resulted in the tumor receiving only 30 percent of the intended fractional dose and resulted in the duodenum (where the HDR source was located) receiving more than 50 rem and more than 50 percent of planned." A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. | General Information or Other | Event Number: 45794 | Rep Org: NE DIV OF RADIOACTIVE MATERIALS Licensee: OMAHA PUBLIC POWER DISTRICT Region: 4 City: OMAHA State: NE County: License #: 01-39-04 Agreement: Y Docket: NRC Notified By: JIM DeFRAIN HQ OPS Officer: PETE SNYDER | Notification Date: 03/26/2010 Notification Time: 13:36 [ET] Event Date: 03/25/2010 Event Time: 11:35 [CDT] Last Update Date: 03/26/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): RICK DEESE (R4DO) ANGELA MCINTOSH (FSME) | Event Text PROCESS GAUGE SHUTTER MALFUNCTION The following information was received from the State of Nebraska via facsimile: "The licensee uses fixed industrial gauges for measuring densities in fly ash hoppers at the station's precipitator building. The industrial gauges contain a Cesium 137 sealed source. The Cesium 137 sources were originally installed in 1975 and at the time contained 50 millicuries per source. "The sources were manufactured and installed by Kay Ray Inc. "The gauges are Model No. 7700-50. "The licensee was attempting to close the shutter on the fixed gauge prior to performing maintenance. One of the external closure cables was found to be slightly bound up and only partially closed the 'internal' source shutter. The cable closure was reopened, which reopened the source shutter up at the sealed source. Closure was tried again. This time the cable, which connects the handle at the floor to the sealed source shutter mechanism 20 feet above, bent instead of sliding the cable to the closed position. "This 'event' happened at 11:35 am and was reported to the station's Shift Supervisor who in turn contacted the plant electricians to make repairs so the precipitator 'tag-out' could continue. By 11:45 am the cable had been closed and the lab contacted to perform a survey to verify the source shutter was now in the closed position. No personnel were exposed to radiation during this event." | Power Reactor | Event Number: 45797 | Facility: ARKANSAS NUCLEAR Region: 4 State: AR Unit: [1] [ ] [ ] RX Type: [1] B&W-L-LP,[2] CE NRC Notified By: DAVID THOMPSON HQ OPS Officer: PETE SNYDER | Notification Date: 03/27/2010 Notification Time: 20:32 [ET] Event Date: 03/27/2010 Event Time: 15:31 [CDT] Last Update Date: 03/31/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(ii)(A) - DEGRADED CONDITION | Person (Organization): RICK DEESE (R4DO) | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 1 | N | N | 0 | Refueling | 0 | Refueling | Event Text POTENTIALLY DEGRADED PRESSURIZER LEVEL TAP IDENTIFIED "Arkansas Nuclear One Unit 1 is currently shut down in Mode 6 for refueling outage 1R22. "On March 27, 2010 at 1531 CDT a visual examination of Unit 1 pressurizer level tap 1-RC-1001 A/B indicated evidence of past leakage from the nozzle bore. The leakage is indicated by a small trail of what appears to be dry boron on the lower portion of the nozzle bore accompanied by rust stains on the stainless steel nozzle." The licensee notified the NRC Resident Inspector. * * * UPDATE FROM DAVID THOMPSON TO DONALD NORWOOD AT 1558 EDT ON 3/31/2010 * * * "Update per 10CFR50.72(c). "During the visual examination of the bore of T1 pressurizer level tap nozzle RC-1001 after the inconel nozzle removal, it is evident that corrosion of the carbon steel base material is present. This nozzle location was identified as leaking during the bare metal visual examination." The licensee notified the NRC Resident Inspector. Notified R4DO (O'Keefe). | General Information or Other | Event Number: 45801 | Rep Org: NE DIV OF RADIOACTIVE MATERIALS Licensee: OMAHA PUBLIC POWER DISTRICT Region: 4 City: OMAHA State: NE County: License #: 01-39-04 Agreement: Y Docket: NRC Notified By: JIM DEFRAIN HQ OPS Officer: DONALD NORWOOD | Notification Date: 03/29/2010 Notification Time: 16:06 [ET] Event Date: 03/27/2010 Event Time: 09:50 [CDT] Last Update Date: 03/29/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): GREG PICK (R4DO) ANDREA KOCK (FSME) | Event Text AGREEMENT STATE REPORT - FIXED DENSITY GAUGE STUCK SHUTTER The following information was received from the State of Nebraska via facsimile: "The licensee uses fixed industrial gauges for measuring densities in fly ash hoppers at the stations precipitator building. The industrial gauges contain a Cesium-137 sealed source. The Cesium-137 sources were originally installed in 1975 and at the time contained 50 millicuries per source. The sources were manufactured and installed by Kay Ray, Inc. The gauges are Model No. 7700-50. "The licensee was attempting to close the shutter on the fixed gauge prior to performing maintenance. One of the external closure cables was found to be slightly bound up and only partially closed the 'internal' source shutter. The cable closure was reopened, which reopened the source shutter up at the sealed source. Closure was tried again. This time the cable, which connects the handle at the floor to the sealed source shutter mechanism 20 feet above, bent instead of sliding the cable to the closed position. The 'event' happened at 9:50 am and was reported to the station's Shift Supervisor who in turn contacted the plant electricians to make repairs so the precipitator 'tag-out' could continue. By 11:00 am the [shutter] had been closed and the lab contacted to perform a survey to verify the source shutter was now in the closed position. No personnel were exposed to radiation during this event." | General Information or Other | Event Number: 45802 | Rep Org: COLORADO DEPT OF HEALTH Licensee: UNKNOWN Region: 4 City: State: CO County: License #: Agreement: Y Docket: NRC Notified By: MARK DATER HQ OPS Officer: DONALD NORWOOD | Notification Date: 03/29/2010 Notification Time: 18:07 [ET] Event Date: 03/29/2010 Event Time: [MDT] Last Update Date: 03/29/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): NEIL OKEEFE (R4DO) ANDREA KOCK (FSME) | Event Text AGREEMENT STATE REPORT - FOUND PORTABLE DENSITY GAUGE The following information was received from the State of Colorado via facsimile: "On 3/29/10 this department was notified of a portable density gauge that had been left at a property that had been foreclosed on. We responded to the property and found a CPN MC-3 density gauge. The s/n M390304939. We have taken possession of the gauge and it is now being stored in a secure area. We have contacted the manufacturer who is attempting to track the serial number." According to the NMED database, this gauge was reported stolen in 1999. The gauge contained 50 mCi of Am-241/Be and 10 mCi of Cs-137. NMED Report #990562. | |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021