Event Notification Report for May 10, 2006
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 05/09/2006 - 05/10/2006 ** EVENT NUMBERS ** | | General Information or Other | Event Number: 42556 | Rep Org: FLORIDA BUREAU OF RADIATION CONTROL Licensee: 21ST CENTURY ONCOLOGY Region: 1 City: CORAL SPRINGS State: FL County: License #: 2667-1 Agreement: Y Docket: NRC Notified By: MARK SEIDENSTRICKER HQ OPS Officer: BILL GOTT | Notification Date: 05/05/2006 Notification Time: 13:49 [ET] Event Date: 03/31/2006 Event Time: [EDT] Last Update Date: 05/05/2006 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): RONALD BELLAMY (R1) TIM HARRIS (NMSS) | Event Text AGREEMENT STATE REPORT - MEDICAL EVENT An 80 year old white female undergoing a Mammosite Brachytherapy (Nuclear Tron V2 model 31662) procedure utilizing Ir-192 source received less than 30% of the prescribed dose of 3400 centi-gray (cGy) (accumulated dose). An incorrect figure was entered into the computer causing the source to stay back 6 cm from the intended position and hence dosing an unintended area of approximately 2 cm with 3 times the prescribed dose of 10,000 cGy. The treatment was given 2 times a day for five days from March 31 to April 7, 2006. The patient saw the attending physician for follow-up on May 2, 2006. The physician discovered the patients skin abnormally red. He contacted the Medical Physicist who investigated and discovered the input error. The physician, patient and the patients family were notified. The patient is well and is being treated for erythema. Florida Incident number: FL 06-062 | | Power Reactor | Event Number: 42563 | Facility: SALEM Region: 1 State: NJ Unit: [1] [ ] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: PAUL ABBOTT HQ OPS Officer: PETE SNYDER | Notification Date: 05/10/2006 Notification Time: 04:36 [ET] Event Date: 05/10/2006 Event Time: 02:15 [EDT] Last Update Date: 05/10/2006 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(2)(xi) - OFFSITE NOTIFICATION | Person (Organization): ANTHONY DIMITRIADIS (R1) S. BAUMGARTNER (NRC) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text NOTIFICATION OF OFFSITE AMMONIA AND HYDRAZINE RELEASE "A notification was made to the New Jersey Department of Environmental Protection of a discharge of approximately 2000 gallons of water containing 30 parts per million (ppm) of hydrazine and 200 ppm of ammonia to the Delaware river, via the storm drain system. The source of the water was a relief valve on the Unit 1 Condensate System that resulted in the overflow of the condensate polisher building sump. The water migrated from the building to the storm drain system. The discharge was terminated at the time of discovery. "There was no equipment out of service that contributed to this event and there were no personnel injuries or radiological occurrences associated with this event." The licensee will notify the NRC Resident Inspector. | |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021