Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for July 3, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           07/02/2003 - 07/03/2003



                              ** EVENT NUMBERS **



39964  39972  39973  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39964       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  LOUISIANA RADIATION PROTECTION DIV   |NOTIFICATION DATE: 06/30/2003|

|LICENSEE:  GULF ENGINEERING CO                  |NOTIFICATION TIME: 14:10[EDT]|

|    CITY:  CONVENT                  REGION:  4  |EVENT DATE:        06/26/2003|

|  COUNTY:                            STATE:  LA |EVENT TIME:        19:17[CDT]|

|LICENSE#:  LA-7415-L01           AGREEMENT:  Y  |LAST UPDATE DATE:  06/30/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CHARLES MARSCHALL    R4      |

|                                                |FRED BROWN           NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  SCOTT BLACKWELL              |                             |

|  HQ OPS OFFICER:  BILL GOTT                    |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT FROM LOUISIANA                                        |

|                                                                              |

| The following was faxed from the Louisiana Department of Environmental       |

| Quality:                                                                     |

|                                                                              |

| "During industrial radiography, the crank-out assembly got in contact with   |

| some hot pipe while the source was cranked out.  The heat from the pipe      |

| melted the rubber housing on the crank-out assembly.  Could not mechanically |

| retract the source.  The radiographers isolated the area and kept personnel  |

| out until AEA Technology could arrive to retrieve the source.  There was no  |

| damage to the exposure device or the source.  There was no exposure to       |

| individuals of the public.  The source was 85 curies of Ir-192."             |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39972       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 07/02/2003|

|    UNIT:  [1] [2] []                STATE:  TN |NOTIFICATION TIME: 00:17[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        07/01/2003|

+------------------------------------------------+EVENT TIME:        18:45[EDT]|

| NRC NOTIFIED BY:  KEN STEVENS                  |LAST UPDATE DATE:  07/02/2003|

|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |JOEL MUNDAY          R2      |

|10 CFR SECTION:                                 |HAROLD CHRISTENSEN   R2      |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |ROBERTA WARREN       TAS     |

|NINF                     INFORMATION ONLY       |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| UNACCOUNTED FOR SECURITY WEAPON                                              |

|                                                                              |

| Unaccounted for security weapon. Immediate compensatory measures taken upon  |

| discovery.  TVA security and NRC Resident Inspector notified.  Refer to HOO  |

| Log for additional details.                                                  |

|                                                                              |

| * * * UPDATE ON 07/02/03 AT 0150 FROM HERBERT EAVES TO ARLON COSTA * * *     |

|                                                                              |

| TVA Police made offsite notification on 07/01/03 at 2300 EDT to the National |

| Crime Information Center pertaining to the unaccounted for security weapon.  |

| The NRC Resident Inspector will be notified of this event update.            |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39973       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: THREE MILE ISLAND        REGION:  1  |NOTIFICATION DATE: 07/02/2003|

|    UNIT:  [] [2] []                 STATE:  PA |NOTIFICATION TIME: 11:27[EDT]|

|   RXTYPE: [1] B&W-L-LP,[2] B&W-L-LP            |EVENT DATE:        07/02/2003|

+------------------------------------------------+EVENT TIME:        10:56[EDT]|

| NRC NOTIFIED BY:  JIM MCKINNEY                 |LAST UPDATE DATE:  07/02/2003|

|  HQ OPS OFFICER:  ARLON COSTA                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          UNUSUAL EVENT         |RICHARD BARKLEY      R1      |

|10 CFR SECTION:                                 |JOSEPH HOLONICH      IRO     |

|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |WILLIAM BECKNER      NRR     |

|                                                |BILL BEECHER         OPA     |

|                                                |MIKE WEBER           NSIR    |

|                                                |DAN SULLIVAN         FEMA    |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          N       0        Decommissioned   |0        Decommissioned   |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| UNUSUAL EVENT DUE TO SWITCHGEAR FIRE IN THE TURBINE BUILDING                 |

|                                                                              |

| The licensee declared an unusual event on 7/2/03 at 1056 EDT according to    |

| Emergency Action Level No.HU4 due to a fire in the non-vital 480 Volt Motor  |

| Control Center switchgear located in turbine building 2-31.  The fire was    |

| put out at 1125 by the fire brigade and no plant personnel were hurt due to  |

| this incident.  The Technical Support Center was not activated for this      |

| event as Unit 2 is decommissioned.                                           |

|                                                                              |

| This incident did not impact Unit 1and it remains at full power operations.  |

| The licensee is making preparations to de-escalate the unusual event and is  |

| in the process of preparing a press release.                                 |

|                                                                              |

|                                                                              |

| * * * UPDATE 1255 ON 07/02/03 JIM MCKINNEY TO GOTT * * *                     |

|                                                                              |

| The licensee terminated from the unusual event at 1245 on 07/02/03.          |

|                                                                              |

| Notified R1DO (Barkley), NRR (Beckner), DHS Operations Officer, Denver, FEMA |

| (Sullivan), NSIR (Wessman), and PAO (Beecher).                               |

+------------------------------------------------------------------------------+



                    