Event Notification Report for April 28, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           04/25/2003 - 04/28/2003



                              ** EVENT NUMBERS **



39780  39790  39796  39797  39799  39800  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39780       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  MARYLAND DEPT OF THE ENVIRONMENT     |NOTIFICATION DATE: 04/22/2003|

|LICENSEE:  ENGINEERING CONSULTANT SERVICES      |NOTIFICATION TIME: 11:05[EDT]|

|    CITY:  FREDERICK                REGION:  1  |EVENT DATE:        04/22/2003|

|  COUNTY:  FREDERICK                 STATE:  MD |EVENT TIME:             [EDT]|

|LICENSE#:  MD2103701             AGREEMENT:  Y  |LAST UPDATE DATE:  04/22/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |HAROLD GRAY          R1      |

|                                                |TOM ESSIG            NMSS    |

+------------------------------------------------+MATT HAHN            IAT     |

| NRC NOTIFIED BY:  ALAN JACOBSON                |                             |

|  HQ OPS OFFICER:  MIKE RIPLEY                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE                       |

|                                                                              |

| The licensee reported that upon arriving at their work site in Bethesda, MD  |

| early in the morning of 04/22/03 they discovered that their construction     |

| trailer was broken into and a moisture density gauge stolen.  The gauge is a |

| CPN Model # MC1DR, S/N MD00305503 containing 10 millicuries Cs-137 and 50    |

| millicuries Am-241:Be.  The licensee notified the Montgomery County Police   |

| (Case # B03089862).                                                          |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39790       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 04/24/2003|

|    UNIT:  [1] [2] []                STATE:  MI |NOTIFICATION TIME: 04:40[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        04/24/2003|

+------------------------------------------------+EVENT TIME:        03:48[EDT]|

| NRC NOTIFIED BY:  STUART SCHUETTPELZ           |LAST UPDATE DATE:  04/25/2003|

|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          ALERT                 |MONTE PHILLIPS       R3      |

|10 CFR SECTION:                                 |JAMES LYONS          NRR     |

|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |MICHELE EVANS        IRO     |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|CHUCK CAIN           R4      |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|CHARLIE BAGWELL      FEMA    |

|                                                |JOHN FLACH           NRC     |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     M/R        Y       100      Power Operation  |0        Hot Standby      |

|2     M/R        Y       100      Power Operation  |0        Hot Standby      |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| ALERT DECLARED                                                               |

|                                                                              |

| At 0348 EDT on 4/24/03, the plant experienced an influx of fish on the       |

| intake screens for the circwater and essential service water (ESW) systems.  |

| This resulted in a loss of vacuum to Units 1 and 2 main turbines, which led  |

| operators to manually trip both reactors.  Following the trip, operators     |

| noted that ESW flow to all 4 emergency diesel generators (EDGs) was severely |

| degraded.  This resulted in the licensee declaring all 4 EDG's inoperable.   |

| An alert was declared at 0348 EDT, and the NRC entered Monitoring Mode at    |

| 0506 EDT.                                                                    |

|                                                                              |

| * * * UPDATE AT 0600 ON 4/24/03 FROM LICENSEE TO H. CROUCH * * *             |

|                                                                              |

| All EDG's have adequate flow to be used in an emergency, but remain          |

| inoperable.                                                                  |

|                                                                              |

| The licensee is assessing damage to intake screens and strainers in the ESW  |

| system, and manually backwashing ESW screens.                                |

|                                                                              |

| * * * UPDATE AT 0718 ON 4/24/03 FROM DEAN BRUCK TO E. THOMAS * * *           |

|                                                                              |

| The licensee made a 4-hour ENS notification under 10 CFR 50.72(b)(2)(iv)(B)  |

| to inform the NRC of the manual reactor trips inserted on Units 1 and 2 at   |

| 0328 and 0329 on 4/24/03 for the reasons listed above.  Post-trip response   |

| of the plant was normal.  Main Steam Isolation Valves were manually closed   |

| on both units due to lowering Reactor Coolant System temperature and         |

| lowering vacuum.  Both units remain in Mode 3.                               |

|                                                                              |

| * * * UPDATE AT 1020 ON 4/24/03 FROM TODD CASPER TO E. THOMAS * * *          |

|                                                                              |

| The licensee made an 8-hour ENS notification under 10 CFR 50.72(b)(3)(iv)(A) |

| to inform the NRC of the Auxiliary Feedwater System (AFW) actuations in      |

| Units 1 and 2 following the reactor trips.  The heat removal path for both   |

| units is via AFW to the steam generator pressure operated relief valves.     |

|                                                                              |

| * * * UPDATE AT 0532 ON 4/25/03 FROM R3 IRC TO E. THOMAS * * *               |

|                                                                              |

| The licensee terminated the Alert at 0521 EDT.  The Alert was terminated     |

| based on having one train of ESW and one EDG declared OPERABLE for each      |

| Unit.  The NRC exited the Monitoring Mode of normal operations at 0532 EDT.  |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39796       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 04/25/2003|

|    UNIT:  [1] [2] []                STATE:  MI |NOTIFICATION TIME: 09:58[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        04/24/2003|

+------------------------------------------------+EVENT TIME:        14:17[EDT]|

| NRC NOTIFIED BY:  LEE BUSH                     |LAST UPDATE DATE:  04/25/2003|

|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MONTE PHILLIPS       R3      |

|10 CFR SECTION:                                 |                             |

|HFIT 26.73               FITNESS FOR DUTY       |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Hot Shutdown     |0        Hot Shutdown     |

|2     N          N       0        Hot Shutdown     |0        Hot Shutdown     |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| FITNESS FOR DUTY                                                             |

|                                                                              |

| A contract employee was determined to be under the influence of marijuana    |

| during a monitor result drug test.  The employee's access to the plant has   |

| been permanently terminated.  Contact the HOO for additional details.        |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39797       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COOPER                   REGION:  4  |NOTIFICATION DATE: 04/25/2003|

|    UNIT:  [1] [] []                 STATE:  NE |NOTIFICATION TIME: 10:24[EDT]|

|   RXTYPE: [1] GE-4                             |EVENT DATE:        03/29/2003|

+------------------------------------------------+EVENT TIME:        01:14[CDT]|

| NRC NOTIFIED BY:  COY L. BLAIR                 |LAST UPDATE DATE:  04/25/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CHUCK CAIN           R4      |

|10 CFR SECTION:                                 |                             |

|AINV 50.73(a)(1)         INVALID SPECIF SYSTEM A|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Refueling        |0        Refueling        |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| 60-DAY OPTIONAL REPORT FOR INVALID SPECIFIED SYSTEM ACTUATION                |

|                                                                              |

| The following information was obtained from the licensee via facsimile:      |

|                                                                              |

| "THIS IS BEING REPORTED PER 10 CFR 50.73(a)(2)(iv)(A).                       |

|                                                                              |

| "The following systems inadvertently actuated:                               |

|                                                                              |

| "Core Spray A                                                                |

| "Core Spray B                                                                |

| "#2 Diesel Generator started and came to speed                               |

|                                                                              |

| "Core Spray A and B were complete actuations.                                |

|                                                                              |

| "#2 Diesel Generator was a partial actuation since it did not load.  There   |

| was no loss of offsite power or requirement to load.                         |

|                                                                              |

| "Affected equipment started and functioned successfully."                    |

|                                                                              |

| The cause of the actuation was human error when the operator performing a    |

| Reactor Protection System surveillance test mechanically actuated the wrong  |

| relay.  The reactor was in refueling and flooded-up at the time of the core  |

| spray actuation.  There was a minor change in skimmer surge tank level       |

| before Operations personnel were able to manually isolate core spray.        |

|                                                                              |

| The licensee still has a Significant Condition Report (SCR) open that should |

| address ways to minimize re-occurrence.                                      |

|                                                                              |

| The licensee will be notifying the NRC Resident Inspector.                   |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39799       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: ROBINSON                 REGION:  2  |NOTIFICATION DATE: 04/26/2003|

|    UNIT:  [2] [] []                 STATE:  SC |NOTIFICATION TIME: 18:23[EDT]|

|   RXTYPE: [2] W-3-LP                           |EVENT DATE:        04/26/2003|

+------------------------------------------------+EVENT TIME:        17:46[EDT]|

| NRC NOTIFIED BY:  EAYRES                       |LAST UPDATE DATE:  04/26/2003|

|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          UNUSUAL EVENT         |MIKE ERNSTES         R2      |

|10 CFR SECTION:                                 |JAMES LYONS          NRR     |

|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |MICHELE EVANS        IRO     |

|                                                |DAN SULLIVAN         FEMA    |

|                                                |ALTERNATE SITE               |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| NOUE DECLARED DUE TO FIRE IN THE OWNER PROTECTED AREA LASTING MORE THAN 10   |

| MINS.                                                                        |

|                                                                              |

| The licensee declared a NOUE at 1803 due to a fire in the owner protected    |

| area on the motor of the  "B" circulating water pump at the intake that      |

| lasted for more than 10 minutes.  There are a total of three pumps and two   |

| are now operable.  The smoking fire (no flames) was extinguished at 1823     |

| with no assistance from offsite.  There were no injuries or damage to the    |

| plant.  The licensee will not issue a press release.                         |

|                                                                              |

| The licensee notified the State of South Carolina, Darling , Lee, and        |

| Chesterfield counties.                                                       |

|                                                                              |

| The NRC Resident Inspector was notified.                                     |

|                                                                              |

| *****UPDATE ON 4/26/03 AT 19:30 FROM EAYRES TO LAURA*****                    |

|                                                                              |

| The NOUE was terminated at 19:23. The electrical fire is out and there was   |

| no impact on continued plant operation.                                      |

|                                                                              |

| Notified R2DO (ERNSTES), DIRO (EVANS), NRR (LYONS), NRC ALTERNATE SITE, FEMA |

| (EACHES)                                                                     |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Fuel Cycle Facility                              |Event Number:   39800       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 04/27/2003|

|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 18:05[EDT]|

| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        04/26/2003|

|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        22:06[CDT]|

|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  04/27/2003|

|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+

|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |

|LICENSE#:  GDP-1                 AGREEMENT:  Y  |MONTE PHILLIPS       R3      |

|  DOCKET:  0707001                              |DANIEL GILLEN        NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  SKAGGS                       |                             |

|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|OSAF 76.120(c)(2)        SAFETY EQUIPMENT FAILUR|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| PLANT HAD A SAFETY EQUIPMENT FAILURE                                         |

|                                                                              |

| At 2208 CST, on 4-26-03 the Plant Shift Superintendent (PSS) was notified    |

| that a UF6 Release Detection System smoke detector for the No. 3 Normetex    |

| Pump in C-315 had fired.   Operators responded and found no indications of a |

| UF6 release.   The No. 3 Normetex Pump was in TSR 2.3.1 Mode 4, "Not In Use" |

| at the time the smoke detector alarmed.   Operators then attempted to reset  |

| the smoke detector and a system trouble alarm was received.   The trouble    |

| alarm would not reset and attempts to test fire the smoke detectors for the  |

| Normetex Pumps was unsuccessful.   At the time of this incident, the C-315   |

| No.1 and No. 2 Normetex Pumps were in an operational mode in which the UF6   |

| Release Detection System was required to be operable, TSR 2.3.4.3 Mode 2,    |

| "Withdrawal".   The PSS declared the system inoperable and TSR LCO 2.3.4.3   |

| actions were implemented to establish a smoke watch and place the Normetex   |

| pumps in Mode 3, "Standby".   The failed smoke detector was replaced, post   |

| maintenance testing completed and the system was declared operable at 0053   |

| CST on 4-27-03.                                                              |

|                                                                              |

| The event is reportable as a 24 hour event, as required by 10 CFR            |

| 76.120(c)(2)(l); "An event in which equipment is disabled or fails to        |

| function as designed when the equipment is required by a TSR to prevent      |

| releases, prevent exposures to radiation and radioactive materials exceeding |

| specified limits, mitigate the consequences of an accident, or restore this  |

| facility to a pre-established safe condition after an accident."  The        |

| equipment was required by TSR to be available and operable and no redundant  |

| equipment was available to perform the required safety function.             |

|                                                                              |

| The NRC Resident Inspector has been notified of this event.                  |

+------------------------------------------------------------------------------+





                    