Event Notification Report for February 27, 2003
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 02/26/2003 - 02/27/2003 ** EVENT NUMBERS ** 39539 39613 39615 39620 39621 39622 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39539 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: CALIFORNIA RADIATION CONTROL PRGM |NOTIFICATION DATE: 01/27/2003| |LICENSEE: ISOTOPE PRODUCTS LABORATORIES |NOTIFICATION TIME: 15:16[EST]| | CITY: BURBANK REGION: 4 |EVENT DATE: 01/23/2003| | COUNTY: LOS ANGELES STATE: CA |EVENT TIME: 16:30[PST]| |LICENSE#: CA-1509 AGREEMENT: Y |LAST UPDATE DATE: 02/26/2003| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM JONES R4 | | |FRED BROWN NMSS | +------------------------------------------------+TIM MCGINTY IRO | | NRC NOTIFIED BY: ROBERT GREGER |CREWS NRC | | HQ OPS OFFICER: GERRY WAIG |JOHN HICKEY NMSS | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT - CONTAMINATED PACKAGE | | | | The following is taken from a facsimile from the State of California: | | | | "On 1/24/03 the RSO [Radiation Safety Officer] @ IPL [Isotope Products | | Laboratories] reported their receipt of a contaminated package. The package | | had been picked up from LAX & delivered to IPL on 1/23 @ 2:25 pm by Kamino | | Int'l Transport, 2580 Santa Fe, Redondo Beach, contact person [DELETED]. The | | package was wiped upon receipt, and received the results approximately 4:30 | | pm. The RSO was notified the next morning. The contamination appears to be | | H-3, although the licensee needs to perform an energy calibration on their | | liquid scintillation counter to verify both this and their quantification of | | the package wipes. It appears that all sides of the package were | | contaminated, at up to approximately 100,000 dpm/wipe. The latest wipes | | measured up to approximately 40,000 dpm/wipe. | | | | "The package came from a company in Switzerland called RC Tritec AG, who is | | a distributor for a Russian company (unknown name at this time). IPL | | believes that the box was trans-shipped, & was never actually at Tritec, but | | they're still trying to get Lufthansa's paperwork. IPL is also trying to get | | info on the Russian company. | | | | "IPL had the delivery truck return to IPL, & they found a small area of | | contamination, about 12 X 10 inches, on the carpet, where the package was | | located, of about 800 dpm/wipe. After vacuuming, they got nothing. About 11 | | other wipes in the truck were negative. They checked the driver's gloves- | | there's no removable contamination. All wipes @ IPL's Shipping Dept were | | negative. They think there was at least one other package on the truck that | | was destined for an electronics company, but they're still trying to get | | info on that. There was at least one other package for IPL on the truck that | | was not contaminated (they're checking to see if it had come from the same | | Russian company). | | | | "Note: Assuming that the contamination is H-3, the dose consequences of | | 100,000 dpm/wipe are approximately equivalent to the dose consequences of | | 2.5 dpm/wipe of Cs-137." | | | | * * * RETRACTION ON 02/26/03 BY GREGER TO CROUCH * * * | | | | This retraction was e-mailed to the Headquarters Operations Officer on | | 1/29/03 but not posted until 02/26/03 due to administrative oversight: | | | | "This package was not contaminated with H-3 as initially thought. The | | substance causing the liquid scintillation counts was a non-radioactive | | phosphorescent material that got on the package at the shippers facility. | | This was confirmed by holding the wipes overnight in a dark environment | | before counting them. THIS REPORT IS BEING RETRACTED." | | | | Notified Fred Brown (NMSS), Eric Leeds (NMSS) and David Graves (R4DO) via | | e-mail. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39613 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 02/24/2003| |LICENSEE: SPECTRO ANALYTICAL INSTRUMENTS |NOTIFICATION TIME: 12:06[EST]| | CITY: MARBLE FALLS REGION: 4 |EVENT DATE: 02/13/2003| | COUNTY: STATE: TX |EVENT TIME: [CST]| |LICENSE#: L-02788-003 AGREEMENT: Y |LAST UPDATE DATE: 02/24/2003| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |DAVID GRAVES R4 | | |DOUG BROADDUS NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: JIM OGDEN | | | HQ OPS OFFICER: HOWIE CROUCH | | +------------------------------------------------+ | |EMERGENCY CLASS: | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT - LEAKING SEALED SOURCE | | | | The following information was obtained from the Texas Department of Health | | via facsimile: | | | | "During routine service of an ASOMA (SPECTRO) Model 200, Serial No 4390, a | | wipe test was performed on a 20 millicurie Am-241 source, Serial No 13730W. | | Contamination of 0.035 microcuries was detected on the wipe. The source is | | an AEA Technology (Amersham) Model AMC.D2 with a source product code | | AMCK2175. It is encapsulated in an X10/2 capsule. The source was removed | | and is being returned to the manufacturer for evaluation. All other | | interior components and exterior surfaces of the instrument were wipe tested | | and found to have no contamination above the Licensee's minimum detection | | limit of 360 picocuries. Agency was notified by telephone of the leaking | | source on February 13, 2003. A written report was sent to this Agency that | | same date. This incident was closed February 24, 2003. No violations have | | been cited. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39615 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 02/24/2003| |LICENSEE: SPECTRO ANALYTIC INSTRUMENTS |NOTIFICATION TIME: 16:46[EST]| | CITY: MARBLE FALLS REGION: 4 |EVENT DATE: 02/24/2003| | COUNTY: STATE: TX |EVENT TIME: 14:00[CST]| |LICENSE#: L-02788-003 AGREEMENT: Y |LAST UPDATE DATE: 02/24/2003| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |DAVID GRAVES R4 | | |ROBERT PIERSON NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: JIM OGDEN | | | HQ OPS OFFICER: HOWIE CROUCH | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT - LEAKING SEALED SOURCE | | | | The following information was obtained from the Texas Department of Health | | via facsimile: | | | | "Leaking source was discovered during routine servicing of an ASOMA Model | | 200 analytical instrument, Serial No 4668. The instrument contained a sealed | | Amersham 13 millicurie, Cm-244 source, Serial No 2695LM, Amersham Model No. | | CLCL. Last assay date was 08/15/95. Leakage detected was from a routine | | wipe test which resulted in 0.0077 microcuries of removable contamination. | | The source is being prepared for return to the manufacturer for evaluation | | and disposal. All other interior components and exterior surfaces of the | | instrument were wipe tested and found to have no contamination above the | | Licensee's minimum detection limit of 360 picocuries." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39620 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: KEWAUNEE REGION: 3 |NOTIFICATION DATE: 02/26/2003| | UNIT: [1] [] [] STATE: WI |NOTIFICATION TIME: 02:05[EST]| | RXTYPE: [1] W-2-LP |EVENT DATE: 02/26/2003| +------------------------------------------------+EVENT TIME: 00:17[CST]| | NRC NOTIFIED BY: FRANSON |LAST UPDATE DATE: 02/26/2003| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: UNUSUAL EVENT |THOMAS KOZAK R3 | |10 CFR SECTION: |MICHAEL JOHNSON NRR | |AAEC 50.72(a) (1) (i) EMERGENCY DECLARED |PATRICK HILAND IRO | |ASHU 50.72(b)(2)(i) PLANT S/D REQD BY TS |AL AUSTIN FEMA | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | PLANT ENTERED A NOUE DUE TO BOTH EMERGENCY DIESEL GENERATORS BEING DECLARED | | INOPERABLE | | | | The licensee declared an unusual event at 0026 CST due to both Emergency | | Diesel Generators being inoperable resulting in the loss of on-site power | | capability. At 0017 the "B" Diesel Generator failed to start during an | | attempt to verify operability as required by TS 3.7.b.2 since the "A" Diesel | | Generator was out of service for maintenance. They are investigating the | | cause for the no start of the "B" Diesel Generator. The plant has 6 hrs to | | be in hot standby and the following 6 hrs to hot shutdown. | | | | The NRC Resident Inspector will be notified. State and local agencies were | | notified and there may be a press release. | | | | * * * UPDATE AT 0804 EST ON 2/26/03 FROM JERRY RISTE TO ARLON COSTA * * * | | | | "Unusual Event Termination | | | | "At 0624 the B emergency diesel generator was returned to service. This | | exited the condition in EPIP-AD-02, Emergency Class Determination," | | requiring declaration of an Unusual Event. At 0656 the Unusual Event was | | terminated." | | | | The licensee replaced a faulty speed sensing relay at the "B" EDG relay | | panel and was subsequently able to re-start the diesel from the control | | room. The unit is currently stable, holding power at 9.3% and all systems | | are functioning as required. The licensee notified the NRC Resident | | Inspector, the State and local authorities. A media/press release was | | issued by the licensee. | | | | Notified R3DO(Kozak), NRR EO (Johnson), DIRO (Hiland) and FEMA (Caldwell). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 39621 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: US ARMY |NOTIFICATION DATE: 02/26/2003| |LICENSEE: US ARMY |NOTIFICATION TIME: 09:54[EST]| | CITY: WINDER REGION: 2 |EVENT DATE: 12/12/2002| | COUNTY: STATE: GA |EVENT TIME: [EST]| |LICENSE#: 19-30563-01 AGREEMENT: Y |LAST UPDATE DATE: 02/26/2003| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WALTER RODGERS R2 | | |ERIC LEEDS NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: DAVID COLLINS | | | HQ OPS OFFICER: YAMIR DIAZ | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |BLO1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | CHEMICAL AGENT DETECTOR DISCOVERED MISSING DURING INVENTORY | | | | A Chemical Agent Detector, serial #Z03-D-04277 containing 300 microcuries of | | Americium-241 was discovered missing during a inventory that took place at | | the US Army Soldiers and Biological/Chemical Command in December 2002. The | | National Guard initiated an investigation to determine location and cause | | of the loss of the missing chemical agent detector. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39622 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: COMANCHE PEAK REGION: 4 |NOTIFICATION DATE: 02/26/2003| | UNIT: [1] [2] [] STATE: TX |NOTIFICATION TIME: 12:12[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 02/25/2003| +------------------------------------------------+EVENT TIME: 17:05[CST]| | NRC NOTIFIED BY: ED LESSMAN |LAST UPDATE DATE: 02/26/2003| | HQ OPS OFFICER: HOWIE CROUCH +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |DAVID GRAVES R4 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION DUE TO SPILL OF BIOCIDE TREATED FIRE PROTECTION WATER | | | | The following information was obtained from the licensee via facsimile: | | | | "On 02/25/2003, we received a fire panel alarm for X-04 fire pump run with | | water flow. The source of leakage was identified as a broken sprinkler | | (40A1) in the MMO building which is located outside our protected area. The | | leak was isolated and the [fire protection] system was placed back in | | standby at 1922 [hrs] that same day. The initial alarm was received at | | 1705. | | | | "On 02/26/2003 at 0915, we notified our contact person (Shannon Kennedy) at | | the TCEQ [Texas Commission on Environmental Quality] by voice mail. The | | following release information: | | | | "'Based on the level change of our fire protection tank, CPSES [Comanche | | Peak Steam and Electric Station] released approx[imately] 11,500 gallons of | | [fire protection] water to the environment. Of that, approx[imately] 8000 - | | 9000 gallons were discharged to our lake (Squaw Creek Res[ervoir]). The | | [fire protection] water contained 50 ppm of biocide and had a pH of 8.5. | | Based on day light visual inspection of our lake, there was no indication of | | stressed or dead fish. There was no observed environmental impact.'" | | | | The NRC Resident Inspector was notified by the licensee. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021