Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for January 9, 2003




                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           01/08/2003 - 01/09/2003



                              ** EVENT NUMBERS **



39490  39495  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39490       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  ARIZONA RADIATION REGULATORY AGENCY  |NOTIFICATION DATE: 01/06/2003|

|LICENSEE:  CONSTRUCTION INSPECTION AND TESTING  |NOTIFICATION TIME: 16:58[EST]|

|    CITY:  Tempe                    REGION:  4  |EVENT DATE:        01/06/2003|

|  COUNTY:                            STATE:  AZ |EVENT TIME:        16:00[MST]|

|LICENSE#:  7-98                  AGREEMENT:  Y  |LAST UPDATE DATE:  01/06/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CHUCK CAIN           R4      |

|                                                |JOHN GREEVES         NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  AUBREY  V. GODWIN            |                             |

|  HQ OPS OFFICER:  ARLON COSTA                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT  - STOLEN MOISTURE DENSITY GAUGE                      |

|                                                                              |

| "At approximately 7:30 AM, January 6, 2003, the Agency [Arizona Radiation    |

| Regulatory Agency] received a voice mail message advising that a Troxler     |

| Model 3440 device, Serial Number 30391, was missing from 4440 West Mountain  |

| View Road, Glendale, AZ.  The device contains 8 millicuries of Cesium-137    |

| and 40 millicuries of Americium-241:Berylium.  The information supplied      |

| indicated that there is [evidence] that the device was stolen.  LICENSEE     |

| believes the source disappeared between 2:00 AM and 6:00 AM January 3, 2003. |

| Agency investigation indicates [that] the lock was cut and the device        |

| removed from the shipping case.  Glendale Police Department is also          |

| investigating this event, report number 03-972.                              |

|                                                                              |

| "The LICENSEE and the Agency continue to investigate this event.             |

|                                                                              |

| "The States of CA, CO, NV, NM, and UT and U.S. NRC and the U.S. FBI are      |

| being notified of this event.  Mexico is also being informed of this event." |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39495       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 01/08/2003|

|    UNIT:  [1] [2] []                STATE:  TX |NOTIFICATION TIME: 11:23[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        01/08/2003|

+------------------------------------------------+EVENT TIME:        04:00[CST]|

| NRC NOTIFIED BY:  GREG JANAK                   |LAST UPDATE DATE:  01/08/2003|

|  HQ OPS OFFICER:  JASON FLEMMING               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CHUCK CAIN           R4      |

|10 CFR SECTION:                                 |                             |

|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LOSS OF ENS AND OFFSITE COMMUNICATION                                        |

|                                                                              |

| "At 04:00 on 01/08/03, normal offsite communications were lost. This         |

| included normal telephone lines, ring down lines to State and County         |

| officials, and the ENS line to the Nuclear Regulatory Commission.            |

| Communications were still available with the STP Coordinator via the ring    |

| down line and the 800 MHz radio. Also had communications established with    |

| offsite personnel via a satellite phone and cellular phones. Communications  |

| with Emergency Response Organization personnel was still available through   |

| backup notification instructions.                                            |

|                                                                              |

| "Normal communications were restored at 07:10 on 01/08/03.                   |

|                                                                              |

| "This is being reported under 10 CFR 50.72(b)(3)(xiii).                      |

|                                                                              |

| "The cause of this event was due to the tripping of a breaker that supplies  |

| power to our offsite communications equipment. This equipment has a battery  |

| backup and the battery supplied power to the communications equipment until  |

| it lost it's energy."                                                        |

|                                                                              |

| NRC Resident inspector notified.                                             |

+------------------------------------------------------------------------------+

                  

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021