Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for November 22, 2002



                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           11/21/2002 - 11/22/2002

                              ** EVENT NUMBERS **

39326  39387  39388  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39326       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PERRY                    REGION:  3  |NOTIFICATION DATE: 10/29/2002|
|    UNIT:  [1] [] []                 STATE:  OH |NOTIFICATION TIME: 03:26[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        10/28/2002|
+------------------------------------------------+EVENT TIME:        23:15[EDT]|
| NRC NOTIFIED BY:  JIM CASE                     |LAST UPDATE DATE:  11/21/2002|
|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES CREED          R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DAMAGED CONTROL ROOM DOOR SEAL                                               |
|                                                                              |
| "Declared both trains of Control Room Emergency Recirc inoperable, entered   |
| Tech Spec 3.0.3 from Tech Spec 3.7.3 on loss of Control Room boundary. A     |
| damaged door seal leading from the Control Complex to the Service building   |
| caused the loss of the Control room boundary. Door was closed and            |
| temporarily sealed per SOI-M25/26. Exited Tech Spec 3.0.3 at 00:15 on        |
| 10/29/02."                                                                   |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
|                                                                              |
| **** RETRACTION on 11/21/02 at 1717EST by Ken Russell taken by MacKinnon     |
| ****                                                                         |
|                                                                              |
| Evaluation determined that the door seal leakage was bounded by a            |
| calculation for degraded Control Room door seals that determined the maximum |
| leakage allowed by the analysis in the Updated Safety Analysis Report (USAR) |
| would not be exceeded even if the entire seal was removed.  Therefore, it    |
| has been concluded that the Control Room boundary was not lost and this was  |
| not a condition that could have prevented the fulfillment of a safety        |
| function.                                                                    |
|                                                                              |
| As indicated in the original notification, entry was made into Technical     |
| Specification 3.0.3 as a result of the assumed loss of Control Room          |
| Emergency Recirculation.  However, the condition was corrected within one    |
| hour, such that it was not necessary to initiate actions to shutdown and     |
| thus this condition was not reported per 10CFR50.73(a)(2)(i)(B), a condition |
| which was prohibited by the plant's Technical Specification.  R3DO (Brent    |
| Clayton) notified.                                                           |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39387       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD             REGION:  3  |NOTIFICATION DATE: 11/22/2002|
|    UNIT:  [1] [] []                 STATE:  IA |NOTIFICATION TIME: 00:03[EST]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        11/21/2002|
+------------------------------------------------+EVENT TIME:        19:55[CST]|
| NRC NOTIFIED BY:  TOM GORDON                   |LAST UPDATE DATE:  11/22/2002|
|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRENT CLAYTON        R3      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       94       Power Operation  |94       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO LAW ENFORCEMENT                                      |
|                                                                              |
| Notifications were made to the FBI and Linn County Sheriff by the licensee.  |
| There was no impact on plant operations.                                     |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| See the HOO Log for additional information.                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39388       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FERMI                    REGION:  3  |NOTIFICATION DATE: 11/22/2002|
|    UNIT:  [2] [] []                 STATE:  MI |NOTIFICATION TIME: 00:50[EST]|
|   RXTYPE: [2] GE-4                             |EVENT DATE:        11/21/2002|
+------------------------------------------------+EVENT TIME:        19:53[EST]|
| NRC NOTIFIED BY:  KEVIN W. DAHM                |LAST UPDATE DATE:  11/22/2002|
|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRENT CLAYTON        R3      |
|10 CFR SECTION:                                 |                             |
|AINA 50.72(b)(3)(v)(A)   POT UNABLE TO SAFE SD  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OPRM CHANNELS DECLARED INOPERABLE                                            |
|                                                                              |
| "On November 21, 2002, Detroit Edison received confirmation from General     |
| Electric of a Non-Conservative Analysis of OPRM Period Setpoint.             |
|                                                                              |
| "The non-conservative analyses affected the OPRM Reactor Protection System   |
| (RPS) scram setpoint. The RPS setpoint may result in violating the Minimum   |
| Critical Power Ratio (MCPR) safety limits during a thermal - hydraulic       |
| instability.                                                                 |
|                                                                              |
| "All OPRM channels have been declared inoperable. Technical Specifications   |
| 3.3.1.1 Action J requires an alternate method of detecting and suppressing   |
| thermal-hydraulic instabilities to be implemented within 12 hours.           |
| Alternate methods have been established, thus the Technical Specification    |
| has been satisfied.                                                          |
|                                                                              |
| "This report is being made in accordance with 10CFR50.72(b)(3)(v), any event |
| or condition that could have prevented the fulfillment of the safety         |
| function of a system needed to shut down the reactor and maintain it in a    |
| safe shutdown condition.                                                     |
|                                                                              |
| "This report is also being made in accordance with 10CFR50.72(b)(3)(vi).     |
| Events covered in paragraph (b)(3)(v) of this section may include one or     |
| more procedural errors, equipment failures, and/or discovery of design,      |
| analysis, fabrication, construction, and/or procedural inadequacies."        |
|                                                                              |
| The NRC Resident Inspector has been notified of this event.                  |
+------------------------------------------------------------------------------+




Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021