Event Notification Report for November 24, 2000
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 11/22/2000 - 11/24/2000 ** EVENT NUMBERS ** 37486 37545 37546 37547 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 37486 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 11/03/2000| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 14:27[EST]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 11/02/2000| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 14:30[CST]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 11/22/2000| | CITY: PADUCAH REGION: 3 +-----------------------------+ | COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION | |LICENSE#: GDP-1 AGREEMENT: Y |DAVID HILLS R3 | | DOCKET: 0707001 |BRIAN SMITH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: MIKE UNDERWOOD | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |OCBB 76.120(c)(2)(ii) EQUIP DISABLED/FAILS | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | CRITICALITY ALARM HORNS AIR PRESSURE FOUND OUT OF SPECIFICATION DURING | | SURVEILLANCE | | | | "At 1330 on 11/2/00, the Plant Shift Superintendent was notified that the | | testing of the C-337 and C-337-A Criticality Accident Alarm System (CAAS) | | air horn regulators resulted in as found data which is outside of the | | optimum air pressure band allowed to insure desired horn sound quality. | | Twelve of the twenty-five CAAS horn regulators located in these two areas | | were discovered outside the desired pressure band. The effect of this as | | found condition is unknown at this time and is being evaluated by | | Engineering. This evaluation will require greater than the 24-hour reporting | | time limit allowed by 10 CFR 76.120.c.2. Due to the uncertainties and the | | length of time required to complete the engineering evaluation the condition | | is being conservatively reported. | | | | "Reasonable assurance of operability of CAAS horns in these and other | | buildings exists based on the successful completion of quarterly and annual | | TSR surveillances. In addition, all CAAS horn regulators found outside of | | established criteria during this and previous tests on other building CAAS | | systems were returned to acceptable values prior to returning the systems to | | service. | | | | "This event is reportable under 10 CFR 76.120(c)(2) as an event in which | | equipment required by the TSR is disabled or fails to function as designed. | | | | "The NRC Senior Resident has been notified of this event." The DOE | | representative will be notified. | | | | * * * RETRACTION 1450 11/22/2000 FROM TOM WHITE TAKEN BY BOB STRANSKY * * * | | | | "On November 2, 2000, the PSS was notified that the testing of the C-337 and | | C-337A CAAS air horns had resulted in the discovery that the horn air | | regulator pressure was outside of the allowed optimum air pressure band used | | to ensure desired horn sound quality. This condition potentially affected | | the audibility of twelve of the twenty-five horns located in the C-337 and | | C-337A. The actual affect on the system was unknown at the time and could | | not be determined within the 24-hour reporting limit. Thus, the condition | | was conservatively reported to the NRC per 10CFR76.120(c)(2). | | | | Subsequently, System Engineering issued Engineering Notice EN-C-822-00-035 | | that transmitted the results of Operability Evaluation OE-C-822-00-005. This | | documented the results of additional CAAS horn testing at the air regulator | | pressure values noted on November 2, 2000 and testing data in other | | buildings. The evaluation concluded that although there is an expected | | amount of drift or variance in the settings of the air pressure regulators | | [for] the CAAS horns, in the as-found condition, could have performed their | | intended safety function and pass the audibility criteria described in the | | SAR." | | | | The NRC resident inspector has been informed of this retraction. Notified | | R3DO (Creed), NMSS (Smith). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 37545 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 11/22/2000| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 14:50[EST]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 11/22/2000| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 03:40[CST]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 11/22/2000| | CITY: PADUCAH REGION: 3 +-----------------------------+ | COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION | |LICENSE#: GDP-1 AGREEMENT: Y |JAMES CREED R3 | | DOCKET: 0707001 |BRIAN SMITH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: T. WHITE | | | HQ OPS OFFICER: BOB STRANSKY | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NCFR NON CFR REPORT REQMNT | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SAFETY SYSTEM ACTUATION | | | | "At 0340 on 11/22/00, the PSS office was notified that a primary condensate | | alarm was received on the C-333A position 3 South autoclave Water Inventory | | Control System (WICS). The WICS system is required to be operable while | | heating in mode 5 according to TSR 2.2.4.2. The autoclave was checked | | according to the alarm response procedure, removed from service and the | | Water Inventory Control System was declared inoperable by the Plant Shift | | Superintendent. The WICS actuation has been determined to be a valid | | actuation by the System Engineer. | | | | "This safety system actuation is reportable to the NRC as required by Safety | | Analysis Report, section 6.9, table 1 criteria J.2, Safety System actuation | | due to a valid signal as a 24-hour event notification." | | | | The NRC Senior Resident Inspector has been notified of this event. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 37546 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: ILLINOIS DEPT OF NUCLEAR SAFETY |NOTIFICATION DATE: 11/22/2000| |LICENSEE: JOHNS MANVILLE INTERNATIONAL |NOTIFICATION TIME: 17:23[EST]| | CITY: WAUKEGAN REGION: 3 |EVENT DATE: 11/21/2000| | COUNTY: STATE: IL |EVENT TIME: [CST]| |LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 11/22/2000| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |JAMES CREED R3 | | |PHILIP TING NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: TOM SIKES | | | HQ OPS OFFICER: BOB STRANSKY | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT | | | | The licensee contacted the State of Illinois to request assistance in | | locating a 20 mCi Cs-137 source. The source was mounted in an Omart model | | SH-F1 holder, and was licensed under a general license. Representatives of | | the state surveyed warehouses and other buildings throughout the licensee's | | facility and other licensee locations, but were unable to locate the source. | | The licensee is currently investigating whether the source may have been | | sent to a licensee facility in Colorado; however, the source may have been | | discarded during renovations to the warehouse in which it had been located. | | In this instance, the source may have been deposited in a landfill in | | Wisconsin. The state is continuing its investigation of this matter. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37547 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: ARKANSAS NUCLEAR REGION: 4 |NOTIFICATION DATE: 11/23/2000| | UNIT: [1] [2] [] STATE: AR |NOTIFICATION TIME: 04:25[EST]| | RXTYPE: [1] B&W-L-LP,[2] CE |EVENT DATE: 11/23/2000| +------------------------------------------------+EVENT TIME: 03:15[CST]| | NRC NOTIFIED BY: WAYNE AHO |LAST UPDATE DATE: 11/23/2000| | HQ OPS OFFICER: FANGIE JONES +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |GAIL GOOD R4 | |10 CFR SECTION: | | |AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N N 0 Cold Shutdown |0 Cold Shutdown | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SPDS OUT OF SERVICE FOR PLANNED MAINTENANCE | | | | The safety parameter display system (SPDS) was deenergized for planned | | maintenance. The system is expected to be down for 2 to 3 hours. | | | | The licensee notified the NRC Resident Inspector and intends to notify the | | state authorities. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021