Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for November 24, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           11/22/2000 - 11/24/2000

                              ** EVENT NUMBERS **

37486  37545  37546  37547  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   37486       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 11/03/2000|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 14:27[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        11/02/2000|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        14:30[CST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  11/22/2000|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |DAVID HILLS          R3      |
|  DOCKET:  0707001                              |BRIAN SMITH          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  MIKE UNDERWOOD               |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|OCBB 76.120(c)(2)(ii)    EQUIP DISABLED/FAILS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CRITICALITY ALARM HORNS AIR PRESSURE FOUND OUT OF SPECIFICATION DURING       |
| SURVEILLANCE                                                                 |
|                                                                              |
| "At 1330 on 11/2/00, the Plant Shift Superintendent was notified that the    |
| testing of the C-337 and C-337-A Criticality Accident Alarm System (CAAS)    |
| air horn regulators resulted in as found data which is outside of the        |
| optimum air pressure band allowed to insure desired horn sound quality.      |
| Twelve of the twenty-five CAAS horn regulators located in these two areas    |
| were discovered outside the desired pressure band. The effect of this as     |
| found condition is unknown at this time and is being evaluated by            |
| Engineering. This evaluation will require greater than the 24-hour reporting |
| time limit allowed by 10 CFR 76.120.c.2. Due to the uncertainties and the    |
| length of time required to complete the engineering evaluation the condition |
| is being conservatively reported.                                            |
|                                                                              |
| "Reasonable assurance of operability of CAAS horns in these and other        |
| buildings exists based on the successful completion of quarterly and annual  |
| TSR surveillances. In addition, all CAAS horn regulators found outside of    |
| established criteria during this and previous tests on other building CAAS   |
| systems were returned to acceptable values prior to returning the systems to |
| service.                                                                     |
|                                                                              |
| "This event is reportable under 10 CFR 76.120(c)(2) as an event in which     |
| equipment required by the TSR is disabled or fails to function as designed.  |
|                                                                              |
| "The NRC Senior Resident has been notified of this event."  The DOE          |
| representative will be notified.                                             |
|                                                                              |
| * * * RETRACTION 1450 11/22/2000 FROM TOM WHITE TAKEN BY BOB STRANSKY * * *  |
|                                                                              |
| "On November 2, 2000, the PSS was notified that the testing of the C-337 and |
| C-337A CAAS air horns had resulted in the discovery that the horn air        |
| regulator pressure was outside of the allowed optimum air pressure band used |
| to ensure desired horn sound quality. This condition potentially affected    |
| the audibility of twelve of the twenty-five horns located in the C-337 and   |
| C-337A. The actual affect on the system was unknown at the time and could    |
| not be determined within the 24-hour reporting limit. Thus, the condition    |
| was conservatively reported to the NRC per 10CFR76.120(c)(2).                |
|                                                                              |
| Subsequently, System Engineering issued Engineering Notice EN-C-822-00-035   |
| that transmitted the results of Operability Evaluation OE-C-822-00-005. This |
| documented the results of additional CAAS horn testing at the air regulator  |
| pressure values noted on November 2, 2000 and testing data in other          |
| buildings. The evaluation concluded that although there is an expected       |
| amount of drift or variance in the settings of the air pressure regulators   |
| [for] the CAAS horns, in the as-found condition, could have performed their  |
| intended safety function and pass the audibility criteria described in the   |
| SAR."                                                                        |
|                                                                              |
| The NRC resident inspector has been informed of this retraction. Notified    |
| R3DO (Creed), NMSS (Smith).                                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   37545       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 11/22/2000|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 14:50[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        11/22/2000|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        03:40[CST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  11/22/2000|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |JAMES CREED          R3      |
|  DOCKET:  0707001                              |BRIAN SMITH          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  T. WHITE                     |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NCFR                     NON CFR REPORT REQMNT  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SAFETY SYSTEM ACTUATION                                                      |
|                                                                              |
| "At 0340 on 11/22/00, the PSS office was notified that a primary condensate  |
| alarm was received on the C-333A position 3 South autoclave Water Inventory  |
| Control System (WICS). The WICS system is required to be operable while      |
| heating in mode 5 according to TSR 2.2.4.2. The autoclave was checked        |
| according to the alarm response procedure, removed from service and the      |
| Water Inventory Control System was declared inoperable by the Plant Shift    |
| Superintendent. The WICS actuation has been determined to be a valid         |
| actuation by the System Engineer.                                            |
|                                                                              |
| "This safety system actuation is reportable to the NRC as required by Safety |
| Analysis Report, section 6.9, table 1 criteria J.2, Safety System actuation  |
| due to a valid signal as a 24-hour event notification."                      |
|                                                                              |
| The NRC Senior Resident Inspector has been notified of this event.           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37546       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ILLINOIS DEPT OF NUCLEAR SAFETY      |NOTIFICATION DATE: 11/22/2000|
|LICENSEE:  JOHNS MANVILLE INTERNATIONAL         |NOTIFICATION TIME: 17:23[EST]|
|    CITY:  WAUKEGAN                 REGION:  3  |EVENT DATE:        11/21/2000|
|  COUNTY:                            STATE:  IL |EVENT TIME:             [CST]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  11/22/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JAMES CREED          R3      |
|                                                |PHILIP TING          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  TOM SIKES                    |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT                                                       |
|                                                                              |
| The licensee contacted the State of Illinois to request assistance in        |
| locating a 20 mCi Cs-137 source. The source was mounted in an Omart model    |
| SH-F1 holder, and was licensed under a general license. Representatives of   |
| the state surveyed warehouses and other buildings throughout the licensee's  |
| facility and other licensee locations, but were unable to locate the source. |
| The licensee is currently investigating whether the source may have been     |
| sent to a licensee facility in Colorado; however, the source may have been   |
| discarded during renovations to the warehouse in which it had been located.  |
| In this instance, the source may have been deposited in a landfill in        |
| Wisconsin. The state is continuing its investigation of this matter.         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37547       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: ARKANSAS NUCLEAR         REGION:  4  |NOTIFICATION DATE: 11/23/2000|
|    UNIT:  [1] [2] []                STATE:  AR |NOTIFICATION TIME: 04:25[EST]|
|   RXTYPE: [1] B&W-L-LP,[2] CE                  |EVENT DATE:        11/23/2000|
+------------------------------------------------+EVENT TIME:        03:15[CST]|
| NRC NOTIFIED BY:  WAYNE AHO                    |LAST UPDATE DATE:  11/23/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GAIL GOOD            R4      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SPDS OUT OF SERVICE FOR PLANNED MAINTENANCE                                  |
|                                                                              |
| The safety parameter display system (SPDS) was deenergized for planned       |
| maintenance.  The system is expected to be down for 2 to 3 hours.            |
|                                                                              |
| The licensee notified the NRC Resident Inspector and intends to notify the   |
| state authorities.                                                           |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021