Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for September 8, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           09/07/2000 - 09/08/2000

                              ** EVENT NUMBERS **

37266  37297  37298  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37266       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT          REGION:  1  |NOTIFICATION DATE: 08/28/2000|
|    UNIT:  [] [2] []                 STATE:  NY |NOTIFICATION TIME: 20:17[EDT]|
|   RXTYPE: [1] GE-2,[2] GE-5                    |EVENT DATE:        08/28/2000|
+------------------------------------------------+EVENT TIME:        16:30[EDT]|
| NRC NOTIFIED BY:  RICHARD LANGE                |LAST UPDATE DATE:  09/08/2000|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |PETE ESELGROTH       R1      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| INOPERABILITY OF THE PASS AND BOTH DIVISION I/II H2O2 MONITORING SYSTEMS     |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "On 8/28/2000, at 1630, [the Division] I and [II] Hydrogen/Oxygen (H2O2)     |
| Containment Monitoring Systems were declared inoperable.  The Division I     |
| system was declared inoperable on 8/28/2000, at 0818, for planned            |
| maintenance.  Subsequently, the Division II system was declared inoperable   |
| due to a failed channel check."                                              |
|                                                                              |
| "In addition, the Post Accident Sampling System (PASS) was previously        |
| declared inoperable.  With the PASS and both Division I/II H2O2 Monitoring   |
| Systems inoperable, this event is reportable in accordance with 10 CFR       |
| 50.72(b)(2)(iii)(D)."                                                        |
|                                                                              |
| "Also, on 8/28/2000, at 1905, the Division I H2O2 Monitor was restored to    |
| operable [status] following completion of planned maintenance."              |
|                                                                              |
| The licensee stated that the unit remained in a 30-day limiting condition    |
| for operation (LCO) and that a 7-day shutdown LCO was exited when the        |
| Division I H2O2 Monitor was restored to operable status.                     |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
|                                                                              |
| ***** UPDATE/RETRACTION AT 0024 ON 09/08/00 FROM ANTHONY PETRELLI TO LEIGH   |
| TROCINE *****                                                                |
|                                                                              |
| The licensee is retracting this event notification.  The following text is a |
| portion of a facsimile received from the licensee:                           |
|                                                                              |
| "On 08/28/00, 1630 EDT, Nine Mile Point Unit 2 reported that Divisions 1 and |
| 2 of the Hydrogen/Oxygen (H2/02) Containment Monitoring Systems were         |
| declared inoperable under Event Number 37266."                               |
|                                                                              |
| "[The licensee is] retracting that notification based on the fact that the   |
| Division 1 H2/O2 monitoring system was removed from service as part of       |
| planned maintenance in accordance with approved procedures and plant         |
| Technical [Specifications].  During planned maintenance, a discrepancy was   |
| found in the Division 1 H2/O2 system.  Subsequent evaluation indicated that  |
| the condition discovered would not have prevented the system from performing |
| its safety function if called upon.  Therefore, this event is not            |
| reportable."                                                                 |
|                                                                              |
| The licensee notified the NRC resident inspector.  The NRC operations        |
| officer notified the R1DO (Dimitriadis).                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37297       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NORTH ANNA               REGION:  2  |NOTIFICATION DATE: 09/07/2000|
|    UNIT:  [1] [] []                 STATE:  VA |NOTIFICATION TIME: 10:01[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        09/07/2000|
+------------------------------------------------+EVENT TIME:        09:58[EDT]|
| NRC NOTIFIED BY:  KEVIN DeVOR                  |LAST UPDATE DATE:  09/07/2000|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MARK LESSER          R2      |
|10 CFR SECTION:                                 |                             |
|AESS 50.72(b)(1)(v)      EMERGENCY SIREN INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| EMERGENCY SIREN OUTAGE DUE TO A PLANNED ACTIVATION ANTENNA UPGRADE           |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "The sirens covering the North Anna Power Station will be taken out of       |
| service for a planned upgrade to the siren activation antenna.  This will    |
| occur between the hours of 1000 and 1300.  Total outage time is              |
| approximately 15 minutes."                                                   |
|                                                                              |
| "Nuclear Emergency Preparedness [personnel have] notified the Virginia       |
| Department of Emergency Management.  Just prior to the outage, the State     |
| [Emergency Operations Center will notify the [five] local jurisdictions.     |
| They will also notify these jurisdictions in the [Emergency Planning Zone]   |
| when the system is returned [to] operable [status]."                         |
|                                                                              |
| The licensee plans to notify the NRC resident inspector.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37298       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  SOUTHEAST MISSOURI STATE UNIVERSITY  |NOTIFICATION DATE: 09/07/2000|
|LICENSEE:  SOUTHEAST MISSOURI STATE UNIVERSITY  |NOTIFICATION TIME: 10:04[EDT]|
|    CITY:  CAPE GIRARDEAU           REGION:  3  |EVENT DATE:        06/12/2000|
|  COUNTY:  CAPE GIRARDEAU            STATE:  MO |EVENT TIME:             [CDT]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  09/07/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |GARY SHEAR           R3      |
|                                                |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CHRIS McGOWAN                |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAD1 20.2202(a)(1)       PERS OVEREXPOSURE      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POTENTIAL PERSONNEL OVEREXPOSURE OF A CONTRACT EMPLOYEE AT SOUTHEAST         |
| MISSOURI STATE UNIVERSITY IN CAPE GIRARDEAU                                  |
|                                                                              |
| HOO NOTE:   Information regarding the same event was reported to the NRC     |
| Operations Center on 09/01/00 by Engelhardt & Associates.  (Refer to event   |
| #37282.)                                                                     |
|                                                                              |
| The licensee was advised by the NRC Region 3 Office to followup on the       |
| report made by Engelhardt & Associates because the work was performed on the |
| Southeast Missouri State University Campus.  The licensee is making this     |
| notification because they want to document that they are aware of this issue |
| and that they agree with the Engelhardt & Associates report.  Another reason |
| for the report is that there may be an issue of who the responsible party is |
| at this point in time.                                                       |
|                                                                              |
| As a result of an NRC visit in February, Southeast Missouri State University |
| discovered that a spill had occurred in the basement of Magill Hall.         |
| Accordingly, Engelhardt & Associates was contracted to perform several tasks |
| including cleanup of the spill.  At the time, the spill was thought to be    |
| minor, and the licensee has since found out that the spill was quite major.  |
| In addition to cleanup of the spill, Engelhardt & Associates was contracted  |
| to help the licensee get ready for a waste haul and help prepare a new       |
| Radiation Plan.  An Engelhardt & Associates representative arrived on        |
| 06/12/00, and he worked in (and out) the basement of Magill Hall for 5       |
| days.                                                                        |
|                                                                              |
| On 09/01/00, the NRC Region 3 Office (Kevin Null) notified the licensee that |
| the Engelhardt & Associates employee had received a dose of 9 REM CEDE.  As  |
| a result, the licensee is in the process of trying to arrange followup       |
| testing for the Engelhardt & Associates employee.  The licensee has also     |
| hired another firm (SAIC) to cleanup some areas of Magill Hall because of a  |
| secondary spill that occurred quite some time ago.  SAIC representatives     |
| have been on campus for a 1-week period already and are expected to return   |
| to the campus on 09/18/00.  SAIC will also be handling the licensee's dose   |
| assessment.                                                                  |
|                                                                              |
| Call the NRC operations officer for licensee contact information.            |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021