Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for August 15, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           08/14/2000 - 08/15/2000

                              ** EVENT NUMBERS **

37223  37224  37225  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37223       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MCGUIRE                  REGION:  2  |NOTIFICATION DATE: 08/14/2000|
|    UNIT:  [1] [] []                 STATE:  NC |NOTIFICATION TIME: 07:42[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        08/14/2000|
+------------------------------------------------+EVENT TIME:        06:58[EDT]|
| NRC NOTIFIED BY:  WESLEY HILL                  |LAST UPDATE DATE:  08/14/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ANNE BOLAND          R2      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BOTH TRAINS OF HIGH PRESSURE INJECTION DECLARED INOPERABLE                   |
|                                                                              |
| The licensee, in the process of a routine train swap between the 1B nuclear  |
| volume control (NV) pump and the 1A NV pump, the 1B discharge check valve    |
| did not fully seat.  Flow from the 1A NV pump was being returned through the |
| 1B NV pump to the suction header.  This could have affected the capability   |
| of both of the NV pumps to perform their required actions in the event that  |
| high head injection to the reactor coolant system was needed.  Both pumps    |
| were declared inoperable at 0658 EDT which made the high head injection      |
| system inoperable.  The discharge valve on the 1B NV pump was shut at 0710   |
| EDT to restore the 1A NV pump to operable.                                   |
|                                                                              |
| The method to be used to restore the 1B NV pump to operable is being         |
| considered.                                                                  |
|                                                                              |
| The licensee intends to notify the NRC Resident Inspector.                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37224       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 08/14/2000|
|LICENSEE:  TERA - MAR, INC.                     |NOTIFICATION TIME: 16:55[EDT]|
|    CITY:  FORT WORTH               REGION:  4  |EVENT DATE:        08/14/2000|
|  COUNTY:                            STATE:  TX |EVENT TIME:             [CDT]|
|LICENSE#:  L03157-008            AGREEMENT:  Y  |LAST UPDATE DATE:  08/14/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CHUCK PAULK          R4      |
|                                                |C.W. (BILL) REAMER   NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES OGDEN                  |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING STOLEN HUMBOLT MODEL 51001 GAUGE            |
|                                                                              |
| "Gauge was stolen from the back of a Company truck while the operator was in |
| a FINA Station at 2910 Loop 12, Dallas, Texas.  The driver had not chained   |
| the gauge in the truck and had noted the presence of "unsavory"  persons     |
| that seemed to be following him and were present at the station when he      |
| exited his vehicle.  When he returned to his vehicle the gauge was missing.  |
| He had the keys and the equipment with which to secure the gauge.            |
|                                                                              |
| "The missing gauge is a Humbolt Model 51001, Serial No.: 2692 with 10        |
| millicurie Cs-137 source, Serial No.: 6604GQ and 40 millicurie Am-241 Be     |
| source, Serial No.: NJ02854.                                                 |
|                                                                              |
| "The operator has been counseled by the RSO.                                 |
|                                                                              |
| "Texas License L03157-008.  Licensee is located in Fort Worth, Texas."       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37225       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: OYSTER CREEK             REGION:  1  |NOTIFICATION DATE: 08/15/2000|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 01:45[EDT]|
|   RXTYPE: [1] GE-2                             |EVENT DATE:        08/15/2000|
+------------------------------------------------+EVENT TIME:        01:40[EDT]|
| NRC NOTIFIED BY:  JERE FREEMAN                 |LAST UPDATE DATE:  08/15/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CLIFFORD ANDERSON    R1      |
|10 CFR SECTION:                                 |                             |
|ASHU 50.72(b)(1)(i)(A)   PLANT S/D REQD BY TS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       86       Power Operation  |78       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| TECHNICAL SPECIFICATION REQUIRED SHUTDOWN DUE TO LOSS OF SECONDARY           |
| CONTAINMENT                                                                  |
|                                                                              |
| Two reactor building isolation valves (V-28-21 and V-28-22) are not          |
| performing their isolation function.  The plant is required to be in the     |
| shutdown mode by 0704 EDT on 8/15/00 and cold shutdown mode by 0904 EDT on   |
| 8/15/00.  The valves were discovered at 0304 EDT on 8/14/00 and the licensee |
| has been working on restoring their function.  The licensee is continuing to |
| try to restore their function and qualify other valves to perform their      |
| function.                                                                    |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021