Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for July 28, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/27/2000 - 07/28/2000

                              ** EVENT NUMBERS **

37188  37189  37190  37191  37192  37193  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37188       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  FLORIDA BUREAU OF RADIATION CONTROL  |NOTIFICATION DATE: 07/27/2000|
|LICENSEE:  QORE, INC. d/b/a ATLANTA TESTING & EN|NOTIFICATION TIME: 10:13[EDT]|
|    CITY:  TAMPA                    REGION:  2  |EVENT DATE:        07/27/2000|
|  COUNTY:                            STATE:  FL |EVENT TIME:        08:30[EDT]|
|LICENSE#:  1646-1                AGREEMENT:  Y  |LAST UPDATE DATE:  07/27/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |STEPHEN CAHILL       R2      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CHARLEY ADAMS                |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE OWNED BY QORE, INC.  |
| d/b/a ATLANTA TESTING & ENGINEERING, INC. LOCATED IN TAMPA, FLORIDA          |
|                                                                              |
| The following text is a portion of a facsimile received from the Florida     |
| Bureau of Radiation Control:                                                 |
|                                                                              |
| "Licensee:  Qore, Inc., d/b/a Atlanta Testing & Engineering, Inc."           |
|                                                                              |
| "City, State, and Zip Code:  Tampa, FL  33313"                               |
|                                                                              |
| "License #:  1646-1"                                                         |
|                                                                              |
| "License Type; Category:  Specific; 3L(1)"                                   |
|                                                                              |
| "Isotope(s):  Cs-137; Am-241:Be"                                             |
|                                                                              |
| "Activity(s):  8 mCi, 40.2 mCi"                                              |
|                                                                              |
| "Material Form; Chemical Form; Physical Form:  By-product: Special Form"     |
|                                                                              |
| "Probable Disposition of Material:  Unknown"                                 |
|                                                                              |
| "Exposure?  No"                                                              |
|                                                                              |
| "Number:  N/A"                                                               |
|                                                                              |
| "Type of Individual(s):  N/A"                                                |
|                                                                              |
| "Exposure Source:  N/A"                                                      |
|                                                                              |
| "Dose Delivered to:  N/A"                                                    |
|                                                                              |
| "Maximum Dose Received:  N/A"                                                |
|                                                                              |
| "Incident Category:  Loss of Control - Lost, Abandoned, or Stolen            |
| Materials"                                                                   |
|                                                                              |
| "Incident Location:  2306 Isabel St., Tampa, FL"                             |
|                                                                              |
| "Location Classification:  Unrestricted Area"                                |
|                                                                              |
| "Incident Description:  [The] licensee reported that a gauge was stolen from |
| a technician's home between 8 p.m. on 26 July and 8 a.m. on 27 July.  The    |
| technician had worked late at a job and went home for the evening.  When he  |
| checked the container the next morning[,] the gauge was missing.  The gauge  |
| is locked[,] but the container had not been locked.  The keys to the gauge   |
| were not stolen.  The Tampa PD and the Florida Bureau of Radiation Control   |
| are investigating.  The licensee is considering [offering] a $500 reward for |
| the gauge's return."                                                         |
|                                                                              |
| "Device Type (Quantity):  Soil Moisture/Density Gauge (1)"                   |
|                                                                              |
| "Manufacturer:  Troxler"                                                     |
|                                                                              |
| "Model Number:  3430"                                                        |
|                                                                              |
| "Serial Number:  23299"                                                      |
|                                                                              |
| "Emergency Groups at Scene:  None"                                           |
|                                                                              |
| "Organizations Notified:  NRC, Tampa PD"                                     |
|                                                                              |
| "Media Contacted:  None"                                                     |
|                                                                              |
| "Investigator's Name; Title:  Charles Adams, Environmental Specialist II"    |
|                                                                              |
| "Office:  Environmental Radiation Control"                                   |
|                                                                              |
| "Date; Time Investigated:  27-Jul-00; 0830"                                  |
|                                                                              |
| "[NRC] Region II has been notified."                                         |
|                                                                              |
| Call the NRC operations officer for contact information.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   37189       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WESTINGHOUSE ELECTRIC CORPORATION    |NOTIFICATION DATE: 07/27/2000|
|   RXTYPE: URANIUM FUEL FABRICATION             |NOTIFICATION TIME: 11:33[EDT]|
| COMMENTS: LEU CONVERSION (UF6 to UO2)          |EVENT DATE:        07/26/2000|
|           COMMERCIAL LWR FUEL                  |EVENT TIME:        12:52[EDT]|
|                                                |LAST UPDATE DATE:  07/27/2000|
|    CITY:  COLUMBIA                 REGION:  2  +-----------------------------+
|  COUNTY:  RICHLAND                  STATE:  SC |PERSON          ORGANIZATION |
|LICENSE#:  SNM-1107              AGREEMENT:  Y  |STEPHEN CAHILL       R2      |
|  DOCKET:  07001151                             |JOSIE PICCONE        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JIM HEATH                    |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24-HOUR NRC BULLETIN 91-01 REPORT                                            |
|                                                                              |
| "During a routine procedure review associated with a plant-wide procedure    |
| upgrade process, a Nuclear Criticality Safety (NCS) engineer noted that a    |
| procedure was not written in compliance with the documented criticality      |
| safety evaluation.                                                           |
|                                                                              |
| "The procedure under review was 'Filter Disassembly Process' which provides  |
| instructions for the disassembly of HEPA filters to remove non-combustible   |
| material and recover gross contamination (i.e. particles which are not       |
| imbedded in the media) prior to incineration. The procedure instructed the   |
| operator to 'Place paper filter media into a 30-gal paper bag for            |
| shredding.' The NCS engineer subsequently examined the criticality safety    |
| evaluation for the shredder system and found that mass control in the system |
| is maintained by administrative controls which prohibit the shredding of     |
| filters surveyed to contain greater than 5g U-235/10 liters. It was          |
| determined that the procedure for shredding of the paper bags filled with    |
| un-assayed filter media failed to provide the documented double contingency  |
| protection for the system.                                                   |
|                                                                              |
| "Double Contingency Protection:                                              |
| Double contingency protection for the shredder is based on mass control      |
| (prevent greater than 43 kg U from accumulating in the feeder hopper or the  |
| receiver drums).  It was determined that less than double contingency        |
| protection remained for the system. However, at no time was greater than a   |
| safe mass involved. In accordance with Westinghouse Operating License        |
| (SNM-1107), paragraph 3.7.3 (c.5), this event meets the criteria for a 24    |
| hour notification because it constitutes a 'nuclear criticality safety       |
| incident, in an analyzed system, for which less than previously documented   |
| double contingency protection remains ...and: Less than a safe mass ... is   |
| involved...'                                                                 |
|                                                                              |
| "Summary of Activity:                                                        |
| Immediately upon determining that less than double contingency protection    |
| remained, the NCS engineer directed that shredding of bags containing        |
| disassembled filter media be stopped. Thus double contingency protection was |
| immediately restored.                                                        |
|                                                                              |
| "Conclusions:                                                                |
| *  Loss of double contingency protection occurred.                           |
| *  At no time was greater than a safe mass involved.                         |
| *  At no time was there any risk to the health or safety of any employee or  |
| member of the public. No exposure to hazardous material was involved.        |
| *  The Incident Review Committee (IRC) determined that this is a safety      |
| significant incident in accordance with governing procedures. A formal root  |
| cause analysis is underway.                                                  |
| *  Notification was the result of a deficient procedure, not 'a deficient    |
| NCS analysis."                                                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37190       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PALISADES                REGION:  3  |NOTIFICATION DATE: 07/27/2000|
|    UNIT:  [1] [] []                 STATE:  MI |NOTIFICATION TIME: 11:50[EDT]|
|   RXTYPE: [1] CE                               |EVENT DATE:        07/26/2000|
+------------------------------------------------+EVENT TIME:        14:27[EDT]|
| NRC NOTIFIED BY:  SHERI KING                   |LAST UPDATE DATE:  07/27/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |THOMAS KOZAK         R3      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| EMERGENCY OFFSITE FACILITY (EOF) TELEPHONE LAND LINES CUT DURING             |
| CONSTRUCTION.                                                                |
|                                                                              |
| "ON 7/26/00 AT APPROXIMATELY 1427 HOURS, IT WAS DISCOVERED THAT ALL LAND     |
| LINKED TELEPHONES IN THE EMERGENCY OFFSITE RESPONSE FACILITY WERE            |
| INOPERATIVE.  SUBSEQUENT INVESTIGATION REVEALED A MAJOR TELEPHONE TRUNK LINE |
| HAD BEEN SEVERED AT APPROXIMATELY 1130 HOURS DURING CONSTRUCTION ACTIVITIES  |
| APPROXIMATELY ONE MILE FROM THE EOF.  THIS SIGNIFICANT LOSS OF TELEPHONES    |
| WOULD HAVE IMPAIRED THE CAPABILITY TO ACTIVATE THE EOF IN THE EVENT OF AN    |
| ACCIDENT OR EMERGENCY.  AT THE TIME OF THE DISCOVERY, COMMUNICATIONS FROM    |
| THE CONTROL ROOM TO THE NRC AND OFFSITE AGENCIES WERE VERIFIED AS            |
| OPERATIONAL.  THE PHONE LINES WERE REPAIRED BY 1700 HOURS ON 7/26/00.        |
|                                                                              |
| "REPORTABILITY OF THE OCCURRENCE WAS DETERMINED AT 1100 HOURS ON 7/27/00."   |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Research Reactor                                 |Event Number:   37191       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: UNIV OF ARIZONA                      |NOTIFICATION DATE: 07/27/2000|
|   RXTYPE: 100 KW TRIGA MARK I                  |NOTIFICATION TIME: 12:00[EDT]|
| COMMENTS:                                      |EVENT DATE:        07/27/2000|
|                                                |EVENT TIME:        08:45[MST]|
|                                                |LAST UPDATE DATE:  07/27/2000|
|    CITY:  TUCSON                   REGION:  4  +-----------------------------+
|  COUNTY:  PIMA                      STATE:  AZ |PERSON          ORGANIZATION |
|LICENSE#:  R-52                  AGREEMENT:  Y  |BILL JONES           R4      |
|  DOCKET:  05000113                             |JIM LYONS            NRR     |
+------------------------------------------------+JOSIE PICCONE        NMSS    |
| NRC NOTIFIED BY:  J.G. WILLIAMS                |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NLTR                     LICENSEE 24 HR REPORT  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24-HOUR REPORT INVOLVING POTENTIAL I-131 CONTAMINATION                       |
|                                                                              |
| "FACILITY LICENSE R-52                                                       |
|                                                                              |
| "Report, possibly spurious, of I-131 contamination                           |
|                                                                              |
| "July 27, 2000                                                               |
|                                                                              |
| "Description of the Occurrence:                                              |
|                                                                              |
| "On the afternoon of July 18, 2000, a routine contamination survey was       |
| performed at the Nuclear Reactor Laboratory (NRL), University of Arizona by  |
| staff of the Radiation Control Office (RCO). On July 26, at approximately    |
| 0845, the Reactor Supervisor received word that four out of 30 wipe samples  |
| showed contamination, with the highest count rate about 1100 counts per      |
| minute. Subsequently, he was told that I-131 (8-day half life) was           |
| identified by gamma spectrometry.                                            |
|                                                                              |
| "Immediate surveys of the Reactor Laboratory and reviews of records showed   |
| no confirmatory evidence, which should have been found if the reported       |
| contamination was genuine.                                                   |
|                                                                              |
| "Contamination of the samples while in RCO custody is suspected, and this    |
| possibility is being investigated.                                           |
|                                                                              |
| "On the morning of 18 July a group of 20 visitors, members of the public,    |
| was present for about one hour in the morning. One half of the visitors,     |
| mostly school children grades 6 to 9, carried pocket dosimeters, which       |
| showed no exposure. The continuous air monitor showed no indication. The     |
| area monitors showed no indication. Finally, no indication of I-131 could be |
| found in the laboratory yesterday, even though no clean-up had been          |
| attempted.                                                                   |
|                                                                              |
| "The report we received from RCO is at the moment considered to be spurious. |
| This report is transmitted within 24 hours of our receiving that report,     |
| however, in case it proves to have some foundation. Investigation is in any  |
| case needed of how this occurred, and of why the report we received from RCO |
| was not timely."                                                             |
|                                                                              |
| * * * UPDATE 7/27/00 FROM J. WILLIAMS TO S. SANDIN VIA FAX * * *             |
|                                                                              |
| The licensee is retracting this report based on the following:               |
|                                                                              |
| "FACILITY LICENSE R-52                                                       |
|                                                                              |
| Withdrawn: previous report, dated today, entitled, "Report, possibly         |
| spurious, of I-131 contamination"                                            |
|                                                                              |
| "July 27, 2000                                                               |
|                                                                              |
| "Investigation of information that formed the basis for my previous report,  |
| dated today, has led to the conclusion that there exists no credible         |
| evidence of any violation of 10CFR20 at this facility or of any other basis  |
| for an immediate report in accordance with our Technical Specification.  In  |
| particular no exposure or contamination of any person has occurred.          |
| Therefore, the previous report is withdrawn.                                 |
|                                                                              |
| "The basis for this conclusion, briefly, is as follows:                      |
|                                                                              |
| "-  The Radiation Control Office has reason to believe that the gamma        |
| spectrometer used to identify I-131 may have been previously contaminated    |
| with I-131.                                                                  |
|                                                                              |
| "-  I-131 is not an isotope in use in the Reactor Laboratory.  It is present |
| in the reactor fuel elements, but could not have leaked from them without    |
| causing other indications that were not present.                             |
|                                                                              |
| "-  The liquid scintillation counts were incorrectly reported by an          |
| inexperienced analyst (though experienced in operating the equipment).       |
|                                                                              |
| "-  At low counting levels, the techniques used to obtain the liquid         |
| scintillation counts may be sensitive to spurious effects such as static     |
| electricity.                                                                 |
|                                                                              |
| "-  Even if accurate, the count rates reported would not credibly lead to    |
| the possibility of exposures above 10CFR20 limits.                           |
|                                                                              |
| "-  The absence of indications from Reactor Laboratory instruments, as       |
| reported previously, cannot be explained if there were any reactivity        |
| released from the reactor. Channel checks of those instruments had been      |
| performed on the day in question (7/18/00), and their calibrations were      |
| current.                                                                     |
|                                                                              |
| "-  In addition to the absence of air monitor indication and area monitor    |
| indication, the reactor pool water monitoring system showed no indication.   |
|                                                                              |
| "-  Further wipe samples of the locations occupied by visitors on 7/18/00,   |
| showed no indications of activity above background, and other wipes from     |
| areas not accessible to visitors showed no significant indications.          |
|                                                                              |
| "As stated in the original report, the reasons for the reporting of possibly |
| spurious data, also after an apparently undue delay, require investigation.  |
| The results will be reported in writing to the NRC within 30 days, as an     |
| 'observed inadequacy in the implementation of administrative or procedural   |
| controls,' (Tech. Specs. 6.7.c.4)."                                          |
|                                                                              |
| Notified R4DO(Jones) and NMSS(Collins).                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37192       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: RIVER BEND               REGION:  4  |NOTIFICATION DATE: 07/27/2000|
|    UNIT:  [1] [] []                 STATE:  LA |NOTIFICATION TIME: 13:54[EDT]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        07/27/2000|
+------------------------------------------------+EVENT TIME:        09:02[CDT]|
| NRC NOTIFIED BY:  VERNON CARLSON               |LAST UPDATE DATE:  07/27/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BILL JONES           R4      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POTENTIAL LOSS OF SAFETY FUNCTION RELATED TO CONTROL ROOM CHILLED WATER      |
| SYSTEM                                                                       |
|                                                                              |
| "While alternating Divisions of Control Room Chilled water to perform post   |
| maintenance testing on HVK-CHL1B the  'B'  chiller tripped. When actions     |
| were taken to restart the 'A'  chiller the breaker for the service water     |
| recirc valve SWP-MOV 27A tripped. The breaker was reset and the chiller was  |
| started.  Due to the  indeterminate nature of the breaker trip on the valve, |
| the 'A'  chiller was declared Inoperable.  The 'C'  & 'D' chillers were      |
| already Inoperable due to non-related existing conditions. This places the   |
| unit in Action  'B'  of Tech Spec 3.7.3. We are conservatively reporting     |
| this pending the investigation of the condition and it's affect on the       |
| system response to postulated events to determine if the safety function was |
| truly lost.  System is currently operating and maintaining normal control    |
| room temperature."                                                           |
|                                                                              |
| The licensee will inform the NRC Resident Inspector.                         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37193       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  IDAHO NAT ENGR & ENVIRONMENTAL LAB   |NOTIFICATION DATE: 07/27/2000|
|LICENSEE:  IDAHO NAT ENGR & ENVIRONMENTAL LAB   |NOTIFICATION TIME: 19:22[EDT]|
|    CITY:  IDAHO FALLS              REGION:  4  |EVENT DATE:        07/27/2000|
|  COUNTY:                            STATE:  ID |EVENT TIME:        15:55[MDT]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  07/28/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BILL JONES           R4      |
|                                                |ELLIS MERSCHOFF      RA      |
+------------------------------------------------+ELMO COLLINS         NMSS    |
| NRC NOTIFIED BY:  JOE GARCIA                   |CHARLES MILLER       IRO     |
|  HQ OPS OFFICER:  STEVE SANDIN                 |STEINDURF            FEMA    |
+------------------------------------------------+DOE, USDA, HHS (fax)         |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| COURTESY NOTIFICATION OF A DOE EMERGENCY DECLARATION AT AN INDEPENDENT SPENT |
| FUEL STORAGE INSTALLATION (ISFSI) IN IDAHO                                   |
|                                                                              |
| At 1555MDT, DOE INEEL declared a Site Area Emergency due to wildland fires   |
| on DOE controlled property.  The ISFSI containing the TMI spent fuel is not  |
| threatened.  This notification is a courtesy call only and does not involve  |
| the NRC Radiological Emergency Plan.  No NRC assistance is requested.        |
|                                                                              |
| DOE INEEL has notified the State of Idaho, all surrounding counties and DOE  |
| Headquarters.                                                                |
|                                                                              |
| *** UPDATE AT 0304 EDT ON 07/28/00 FROM JOE GARCIA AND FOREST HOLMS TO LEIGH |
| TROCINE ***                                                                  |
|                                                                              |
| This event status update was provided as a courtesy notification.   The Site |
| Area Emergency remains in progress.  There is a site-wide emergency action   |
| level in effect because of a wildland fire.  The TMI-2 ISFSI is located at   |
| the Idaho National Engineering & Environmental Laboratory (INEEL), but the   |
| Site Area Emergency does not impact the TMI-2 ISFSI.  However, INEEL has     |
| been directed by the Department of Energy (DOE) to notify the NRC when       |
| emergency action levels of this nature are in place.  The Site Area          |
| Emergency will remain in effect until the fire is extinguished.              |
|                                                                              |
| The following text is a portion of a facsimile received from the INEEL:      |
|                                                                              |
| "Description of Incident:  Wildland fire on the INEEL.  Fire suppression     |
| efforts continue.  Emergency response centers [are] operational at RWMC,     |
| CFA, INTEC, TRA, EOC with reduced staffing.  INTEC and TRA [are] continuing  |
| to monitor facilities."                                                      |
|                                                                              |
| The NRC operations officer notified the R4DO (Jones), R4RA (Merschoff), NMSS |
| EO (Collins), IRO (Miller), and the Federal Emergency Management Agency      |
| (FEMA) (Storer).  DOE, U.S. Department of Agriculture (USDA), Department of  |
| Health and Human Services (HHS), Environmental Protection Agency (EPA), and  |
| Department of Transportation (DOT) (via the National Response Center) were   |
| also notified via facsimile.                                                 |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021