Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for July 24, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/21/2000 - 07/24/2000

                              ** EVENT NUMBERS **

37181  37182  37183  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37181       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK                 REGION:  1  |NOTIFICATION DATE: 07/21/2000|
|    UNIT:  [1] [] []                 STATE:  NH |NOTIFICATION TIME: 11:26[EDT]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        07/21/2000|
+------------------------------------------------+EVENT TIME:        08:20[EDT]|
| NRC NOTIFIED BY:  GARY KILBY                   |LAST UPDATE DATE:  07/21/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GREGORY CRANSTON     R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO INADVERTENT ACTUATION OF OFFSITE SIREN           |
|                                                                              |
| During maintenance on an out-of-service emergency offsite siren, it was      |
| inadvertently actuated for about 30 seconds.  The licensee notified the      |
| Massachusetts Emergency Management Agency as well as the Newbury and Newbury |
| Port Emergency Directors.                                                    |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37182       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NTH CONSULTANTS                      |NOTIFICATION DATE: 07/23/2000|
|LICENSEE:  NTH CONSULTANTS                      |NOTIFICATION TIME: 18:00[EDT]|
|    CITY:  DETROIT                  REGION:  3  |EVENT DATE:        07/23/2000|
|  COUNTY:                            STATE:  MI |EVENT TIME:        12:00[EDT]|
|LICENSE#:  21-14894-01           AGREEMENT:  N  |LAST UPDATE DATE:  07/23/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MICHAEL PARKER       R3      |
|                                                |PATRICIA HOLAHAN     NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JIM PARSONS                  |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STOLEN TROXLER GAUGE                                                         |
|                                                                              |
| A model 3440 Troxler moisture/density gauge was stolen along with a company  |
| truck from NTH Consultants in Detroit, MI.  The theft occurred between noon  |
| and 3:30pm on 7/23/00.  The gauge contains 8 mCi of Cs-137 and 40 mCi of     |
| Am-241.  The gauge was chained to the bed of the truck at the time of the    |
| theft.  A report is being filed with the Detroit Police Department, the      |
| Michigan State Police and the State radiation offices will be notified.      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37183       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY                    REGION:  2  |NOTIFICATION DATE: 07/23/2000|
|    UNIT:  [1] [2] []                STATE:  VA |NOTIFICATION TIME: 20:42[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        07/23/2000|
+------------------------------------------------+EVENT TIME:        20:10[EDT]|
| NRC NOTIFIED BY:  RAWLEIGH DILLARD             |LAST UPDATE DATE:  07/23/2000|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BRIAN BONSER         R2      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF PLANT COMPUTER                                                       |
|                                                                              |
| "At 1910 hours on 7/23/00, the Safety Parameter Display System (SPDS)        |
| portion of the Emergency Response Facility Computer System (ERFCS) was noted |
| to be inoperable, due to all outputs being displayed in magenta color.       |
| Several attempts were made to reboot the system, but were unsuccessful.  The |
| air conditioning system for the Technical Support Center (TSC) computer room |
| (which houses the ERFCS) had failed earlier in the day, and the air          |
| conditioning system was secured to perform repairs.  Portable cooling fans   |
| were being used to cool the TSC computer room and the room temperature had   |
| stayed at about 80 degrees F.  The system must be secured if temperature     |
| rises above 85 degrees F.                                                    |
|                                                                              |
| "Repairs to the TSC computer room air conditioning system are continuing at  |
| this time.  A return to service time for the SPDS portion of the ERFCS has   |
| not been determined at this time."                                           |
|                                                                              |
| The licensee will notify the NRC resident inspector.                         |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021