Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for June 16, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/15/2000 - 06/16/2000

                              ** EVENT NUMBERS **

37084  37085  37086  37087  37088  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37084       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK                REGION:  2  |NOTIFICATION DATE: 06/15/2000|
|    UNIT:  [1] [2] []                STATE:  NC |NOTIFICATION TIME: 07:51[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        06/15/2000|
+------------------------------------------------+EVENT TIME:        06:57[EDT]|
| NRC NOTIFIED BY:  JOE COSTA                    |LAST UPDATE DATE:  06/15/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RUDOLPH BERNHARD     R2      |
|10 CFR SECTION:                                 |                             |
|AESS 50.72(b)(1)(v)      EMERGENCY SIREN INOP   |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF NINE EMERGENCY OFFSITE SIRENS DUE TO LOSS OF LOCAL POWER             |
|                                                                              |
| The licensee was notified that at 0657 EDT that nine of the offsite          |
| emergency warning sirens were deenergized at 0408 EDT due to local power     |
| outage and were inoperable for greater than one hour.  Six were restored in  |
| 1 hour and 16 minutes and the other three were restored in 2 hours and 16    |
| minutes.  All sirens are now operable.                                       |
|                                                                              |
| The licensee notified the NRC Resident Inspector and the State authorities.  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37085       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  FLORIDA BUREAU OF RADIATION CONTROL  |NOTIFICATION DATE: 06/15/2000|
|LICENSEE:  PROFESSIONAL SERVICE INDUSTRIES INC  |NOTIFICATION TIME: 10:25[EDT]|
|    CITY:  TAMPA                    REGION:  2  |EVENT DATE:        06/14/2000|
|  COUNTY:                            STATE:  FL |EVENT TIME:        09:00[EDT]|
|LICENSE#:  22-12                 AGREEMENT:  Y  |LAST UPDATE DATE:  06/15/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |RUDOLPH BERNHARD     R2      |
|                                                |                             |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CHARLES ADAMS (FACSIMILE)    |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT                                                       |
|                                                                              |
| The State of Florida Bureau of Radiation Control reported that a Troxler     |
| soil moisture/density gauge (Model 3430, Serial #30059), containing 8 mCi of |
| Cs-137 and 40 mCi of Am-241/Be, had been stolen from a state licensee. The   |
| licensee reported that the gauge was stolen from a temporary job site        |
| between the hours of 6 p.m. on 6/13/00 and 9 a.m. on 6/14/00. The chain link |
| fence surrounding the site was not damaged, but the door to the shed had     |
| been pried open. The lock on the storage locker containing the container and |
| gauge had been cut. The gauge and container were the only items taken. The   |
| Hillsborough Sheriff's Office and the Florida Bureau of Radiation Control    |
| are investigating. The Sheriff's Office is planning to issue a press         |
| release.                                                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   37086       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  SIOUX VALLEY HOSPITAL                |NOTIFICATION DATE: 06/15/2000|
|LICENSEE:  SIOUX VALLEY HOSPITAL                |NOTIFICATION TIME: 13:52[EDT]|
|    CITY:  SIOUX FALLS              REGION:  4  |EVENT DATE:        04/04/2000|
|  COUNTY:                            STATE:  SD |EVENT TIME:        12:30[MDT]|
|LICENSE#:  40-12378-01           AGREEMENT:  N  |LAST UPDATE DATE:  06/15/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA SMITH          R4      |
|                                                |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  DOUG WARNER                  |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|LADM 35.33(a)            MED MISADMINISTRATION  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PATIENT  DID NOT RECEIVE THERAPEUTIC DOSE OF I-131 AS PRESCRIBED             |
|                                                                              |
| On 4/4/2000 at 1230 hours a patient undergoing treatment for thyroid cancer  |
| did not receive the 100 mCi of I-131 as stated in the written instructions.  |
| The Patient Appointment Center misinterpreted the instruction "100mCi I-131  |
| followed by a whole body scan" to mean "I-131 whole body scan."  A           |
| diagnostic administration of 4.26 mCi I-131  was given for the whole body    |
| scan.  The whole body scan results were reviewed and the prescribing         |
| physician concluded that the therapeutic dose was not required.  The patient |
| was informed.  The Heath Physicist consultant to the hospital reviewed the   |
| incident and advised the hospital that the error was recordable but not      |
| reportable.  This report is being made following an inspection by NRC Region |
| 4 (J. Cruz).                                                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37087       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CLINTON                  REGION:  3  |NOTIFICATION DATE: 06/15/2000|
|    UNIT:  [1] [] []                 STATE:  IL |NOTIFICATION TIME: 21:54[EDT]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        06/15/2000|
+------------------------------------------------+EVENT TIME:        19:15[CDT]|
| NRC NOTIFIED BY:  MARSHALL FUNKHOUSER          |LAST UPDATE DATE:  06/15/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |DAVID HILLS          R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HIGH PRESSURE CORE SPRAY (HPCS) DECLARED INOPERABLE DUE TO INCOMPLETE POST   |
| MODIFICATION TESTING OF IT'S ASSOCIATED DIESEL GENERATOR                     |
|                                                                              |
| "At 1915 on 6/15/00 a Engineering review of a plant modification to the      |
| Division 3 Diesel Generator (DG) determined that the Post Modification       |
| Testing did not verify proper operation of the Loss of Off-Site Power (LOOP) |
| circuitry. This modification had only been performed to Division 3 DG and    |
| therefore Division 1 and 2 DG's are not affected. Division 3 DG provides     |
| power to the High Pressure Core Spray (HPCS) pump. The failure of Division 3 |
| DG to operate during a LOOP would have prevented HPCS from operating. The    |
| loss of a single train safety system such as HPCS is reportable under        |
| 10CFR50.72(b)(2)(iii)(D)."                                                   |
|                                                                              |
| The plant modification involved rewiring the electrical circuit to correct   |
| for a degraded voltage condition and was completed on 1/24/99.  Post         |
| modification testing was completed on 1/31/99.  HPCS has been declared       |
| inoperable but is available, if needed, pending completion of additional     |
| testing.  The licensee will inform the NRC Resident Inspector.               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37088       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 06/15/2000|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 22:10[EDT]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        06/15/2000|
+------------------------------------------------+EVENT TIME:        21:37[EDT]|
| NRC NOTIFIED BY:  DAN GOLDSTON                 |LAST UPDATE DATE:  06/15/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RUDOLPH BERNHARD     R2      |
|10 CFR SECTION:                                 |                             |
|ASHU 50.72(b)(1)(i)(A)   PLANT S/D REQD BY TS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |99       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT COMMENCED A CONTROLLED TECH SPEC REQUIRED SHUTDOWN TO MODE 2 FOR        |
| REPAIRS                                                                      |
|                                                                              |
| "The 'C' steam generator Feedwater Isolation Valve, XVG1611C, air operator   |
| developed an air leak and was declared inoperable 6/13/00 at 1549EDT.        |
| Efforts to stop the leak were unsuccessful.  At 2137EDT on 6/15/00 a         |
| controlled power reduction to mode 2 was started.  Current plans are to      |
| repair the operator in mode 2 and return to power operation."                |
|                                                                              |
| The air leak is ongoing with the affected valve in use (open).  The licensee |
| anticipates entering mode 2 by 0600EDT on 6/16/00 and has informed the NRC   |
| Resident Inspector.                                                          |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021