Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for May 25, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           05/24/2000 - 05/25/2000

                              ** EVENT NUMBERS **

37024  37025  37026  37027  37028  37029  37030  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37024       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CALIFORNIA DEPT OF HEALTH SERVICES   |NOTIFICATION DATE: 05/24/2000|
|LICENSEE:  STERIGENICS INTERNATIONAL            |NOTIFICATION TIME: 13:10[EDT]|
|    CITY:  HAYWARD                  REGION:  4  |EVENT DATE:        05/23/2000|
|  COUNTY:                            STATE:  CA |EVENT TIME:        12:29[PDT]|
|LICENSE#:  6268-01               AGREEMENT:  Y  |LAST UPDATE DATE:  05/24/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CLAUDE JOHNSON       R4      |
|                                                |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  PENDERGAST                   |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE RADIOLOGICAL HEALTH BRANCH OF THE CALIFORNIA DEPARTMENT OF HEALTH        |
| SERVICES WAS NOTIFIED BY STERIGENICS INTERNATIONAL THAT THEY HAD A CABLE JAM |
| ON THEIR SOURCE HOIST ARRAY.                                                 |
|                                                                              |
| THIS OCCURRED ON THEIR 600,000 CURIE POOL IRRADIATOR WHILE THEY WERE         |
| LOWERING THE SOURCE ARRAY INTO THE SHIELDED POSITION AND THE SOURCE HOIST    |
| CABLE JAMMED DUE TO A FRAY ON THE CABLE.  THEY LOOSENED THE SHIELDING AROUND |
| THE SOURCE HOIST CABLE AND THAT ALLOWED THE SOURCES TO BE RETURNED TO THE    |
| SAFE POSITION.  THERE WERE NO OVEREXPOSURES AND NO ABNORMAL RADIATION        |
| LEVELS.  THE PLANT WAS SHUTDOWN UNTIL MAINTENANCE WAS COMPLETED THIS MORNING |
| @ 6:00.                                                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37025       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WATERFORD                REGION:  4  |NOTIFICATION DATE: 05/24/2000|
|    UNIT:  [3] [] []                 STATE:  LA |NOTIFICATION TIME: 14:45[EDT]|
|   RXTYPE: [3] CE                               |EVENT DATE:        05/24/2000|
+------------------------------------------------+EVENT TIME:        12:50[CDT]|
| NRC NOTIFIED BY:  SCOTT                        |LAST UPDATE DATE:  05/24/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CLAUDE JOHNSON       R4      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DISCOVERY OF COMPROMISE OF CLASSIFIED DOCUMENTS/SAFEGUARDS INFORMATION.      |
|                                                                              |
| IMMEDIATE COMPENSATORY MEASURES TAKEN UPON DISCOVERY.                        |
|                                                                              |
| REFER HOO LOG FOR ADDITIONAL DETAILS.                                        |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37026       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 05/24/2000|
|    UNIT:  [1] [2] []                STATE:  WI |NOTIFICATION TIME: 15:48[EDT]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        05/24/2000|
+------------------------------------------------+EVENT TIME:        14:08[CDT]|
| NRC NOTIFIED BY:  ROBBINS                      |LAST UPDATE DATE:  05/24/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GEOFFREY WRIGHT      R3      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF VENTILATION TO PAB BATTERY AND INVERTER ROOMS DURING AN APPENDIX R   |
| FIRE                                                                         |
|                                                                              |
| DURING THE FINAL REVIEW OF THE NEW APPENDIX R REBASELINE PROJECT IT WAS      |
| DISCOVERED THAT VENTILATION TO THE PAB BATTERY AND INVERTER ROOMS WOULD BE   |
| LOST FOR GREATER THAN 2 HOURS FOR AN APPENDIX R FIRE.  FIRE ROUNDS IN THE    |
| AFFECTED AREAS HAVE BEEN STARTED AND PROCEDURE REVISIONS ARE IN PROGRESS TO  |
| ESTABLISH PORTABLE VENTILATION AS NEEDED.                                    |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED.                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37027       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 05/24/2000|
|    UNIT:  [] [] [3]                 STATE:  AL |NOTIFICATION TIME: 15:50[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        05/24/2000|
+------------------------------------------------+EVENT TIME:        13:54[CDT]|
| NRC NOTIFIED BY:  GOLDEN                       |LAST UPDATE DATE:  05/24/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MARK LESSER          R2      |
|10 CFR SECTION:                                 |JOHN HANNON          NRR     |
|ACCS 50.72(b)(1)(iv)     ECCS INJECTION         |JOSEPH GIITTER       IRO     |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|                                                   |                          |
|3     A/R        Y       100      Power Operation  |0        Hot Standby      |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE PLANT HAD A REACTOR SCRAM FROM 100% POWER DUE TO LOW REACTOR WATER       |
| LEVEL                                                                        |
|                                                                              |
| At 13:54 CDT, unit 3 reactor scrammed due to low reactor water level. All    |
| rods fully inserted into the core. The expected groups 2, 3, 6 and 8         |
| isolations were received.  Both recirc pumps tripped, all Standby Gas        |
| Treatment trains started and the 'A' CREV started. The expected Refuel zone  |
| and unit 3 reactor zone isolations were received.  Both the HPCI system and  |
| the RCIC system automatically initiated and injected due to low level        |
| following the scram.  The actual signal perturbation that caused the reactor |
| trip on low water level is still being investigated.  Currently the plant is |
| in a stable condition in mode 3 with investigations in progress.  No relief  |
| valves lifted and HPCI was secured within the first 5 minutes and RCIC       |
| secured a few minutes later.                                                 |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37028       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  WASHINGTON DEPARTMENT OF HEALTH      |NOTIFICATION DATE: 05/24/2000|
|LICENSEE:  ANVIL CORPORATION                    |NOTIFICATION TIME: 18:05[EDT]|
|    CITY:  BELLINGHAM               REGION:  4  |EVENT DATE:        05/11/2000|
|  COUNTY:                            STATE:  WA |EVENT TIME:        00:00[PDT]|
|LICENSE#:  WN-IR031-1            AGREEMENT:  Y  |LAST UPDATE DATE:  05/24/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CLAUDE JOHNSON       R4      |
|                                                |WAYNE HODGES         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  FRAZEE                       |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| Licensee had a source disconnect occur due to a mechanical failure of the    |
| drive cable connector.                                                       |
|                                                                              |
| A source disconnect attributable to mechanical failure of the drive cable    |
| connector occurred during use of a cobalt 60 radiographic exposure device on |
| May 11. Radiography is routinely conducted by this licensee in a shielded    |
| vault (a permanent radiographic installation). An AEA Technologies Model 676 |
| cobalt 60 camera, serial number B105, is generally left set-up between       |
| shots. The routine daily equipment check includes a visual check to confirm  |
| that the drive cable and camera are still connected. The last quarterly      |
| maintenance inspection was at the end of March 2000 and no problems with the |
| drive cable connector were noted. However, during the first shot of the day, |
| the radiographer noticed that the source did not go out smoothly and then    |
| failed to retract. The RSO was contacted and after several more attempts to  |
| retract the source the licensee decided to secure the area and call in the   |
| manufacturer's retrieval experts.  Additional shielding, locks and posting   |
| were added and a survey of the area including the roof showed no readings    |
| above 1 mrem per hour. The state Division of Radiation Protection was        |
| notified and staff observed the retrieval on May 12.  Once the source was    |
| secured, the failed equipment was inspected.  No problems were noted with    |
| the source assembly or the camera.  However, the ball fitting at the drive   |
| cable connector's end had become separated from the cable.  AEA Technologies |
| took the separated ball and 4 inches of the end of the drive cable back to   |
| AEA for analysis.                                                            |
|                                                                              |
| What is the notification or reporting criteria involved? WAC 246-221-250     |
| Notification of incidents (equipment failure)                                |
|                                                                              |
| Activity and isotope(s) involved: 71 curies of Cobalt 60.                    |
|                                                                              |
| Overexposures? There were no overexposures (however, retrieval personnel     |
| received 130 and 65 mrem whole body exposures)                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37029       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  WASHINGTON DEPARTMENT OF HEALTH      |NOTIFICATION DATE: 05/24/2000|
|LICENSEE:  SPEARS ENGINEERING & TECHNICAL SERVIC|NOTIFICATION TIME: 18:26[EDT]|
|    CITY:  SOUTH SEATTLE            REGION:  4  |EVENT DATE:        05/22/2000|
|  COUNTY:                            STATE:  WA |EVENT TIME:        18:00[PDT]|
|LICENSE#:  WN-I0357-1            AGREEMENT:  Y  |LAST UPDATE DATE:  05/24/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CLAUDE JOHNSON       R4      |
|                                                |WAYNE HODGES         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  FRAZEE                       |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LICENSEE REPORTED A STOLEN PORTABLE GAUGE.                                   |
|                                                                              |
| The licensee reported on May 23 that at approximately 6:00 PM the previous   |
| evening a Seaman Nuclear C-200 gauge, serial number A-872, with 4.5          |
| milligrams of Ra-226 was stolen. The licensee's technician had stopped by a  |
| friend's house in South Seattle on his way home. While there, his pickup     |
| truck was stolen from in front of the house. The gauge was locked, in a      |
| locked transport box, and the box was chained and locked in the bed of the   |
| truck. The licensee believes the thief wanted only the truck and will        |
| probably abandon the gauge. The police were notified and the licensee was    |
| advised to notify the local papers and post a reward.                        |
|                                                                              |
| Overexposures? Unknown                                                       |
|                                                                              |
| Disposition/recovery: Unknown at this time                                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37030       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HOPE CREEK               REGION:  1  |NOTIFICATION DATE: 05/24/2000|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 20:27[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        05/24/2000|
+------------------------------------------------+EVENT TIME:        18:04[EDT]|
| NRC NOTIFIED BY:  SERATA                       |LAST UPDATE DATE:  05/24/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |DAN HOLODY           R1      |
|10 CFR SECTION:                                 |JOSEPH GIITTER       IRO     |
|NINF                     INFORMATION ONLY       |JACK CRLENJAK        R1      |
|                                                |JOHN HANNON          NRR     |
|                                                |JOHN ZWOLINSKI       NRR     |
|                                                |ROY ZIMMERMAN        NRR     |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       19       Power Operation  |19       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MAIN TRANSFORMER EXPLOSION AND FIRE WITHIN FIVE FEET OF THE TURBINE          |
| BUILDING.                                                                    |
|                                                                              |
| PRIOR TO THE EVENT, THEY HAD JUST CLOSED THE MAIN TURBINE AND GENERATOR      |
| OUTPUT BREAKERS SO THAT THE TURBINE WOULD SYNCHRONIZE TO THE GRID.  AT 1804  |
| A MAIN TURBINE TRIP AND MAIN TRANSFORMER TROUBLE ALARM WAS  RECEIVED IN THE  |
| CONTROL ROOM.  SUBSEQUENT TO THE TURBINE TRIP, MAIN GENERATOR TRANSFORMER    |
| FIRE ALARMS WERE RECEIVED AND VISUAL VERIFICATIONS CONFIRMED A FIRE ON THE   |
| "C" PHASE OF THE MAIN GENERATOR TRANSFORMER.  THE FIRE DELUGE SYSTEM         |
| ACTIVATED, AND ALTHOUGH EXTERNAL INDICATION THE FIRE HAD CEASED, IT IS       |
| EXPECTED THAT THE FIRE CONTINUES TO BURN INTERNALLY TO THE TRANSFORMER.  ALL |
| OFFSITE POWER SOURCES ARE STILL AVAILABLE.  NO OFFSITE FIRE ASSISTANCE HAS   |
| BEEN REQUESTED.  THE FIRE HAS BEEN ONGOING INTERNALLY FOR APPROXIMATELY TWO  |
| HOURS.  THEY ARE IN THE PROCESS OF ELECTRICALLY ISOLATING THE TRANSFORMER    |
| FROM BOTH THE GENERATOR AND THE GRID AND TAGGING IT OUT.  DELUGE ACTUATION   |
| HAS BEEN SECURED AND THEY ARE SPRAYING THE TRANSFORMER WITH FIRE WATER. THEY |
| ARE ALSO MAKING PREPARATIONS TO USE A FOAM FIRE SUPPRESSION AGENT.           |
|                                                                              |
| FURTHER EVALUATION CONTINUES IN REGARD TO THE ENVIRONMENTAL IMPLICATIONS OF  |
| THE EVENT.  SPECIFICALLY, THE ABILITY OF THE PLANT OIL WASTE SYSTEM TO       |
| PROPERLY PROCESS THE MIXTURE OF WATER AND OIL THAT WERE PRODUCTS OF THE      |
| COMPONENT FAILURE AND SUBSEQUENT FIRE FIGHTING EFFORTS.                      |
|                                                                              |
| THE LICENSEE WILL KEEP THE NRC INFORMED OF ANY ADVERSE CHANGES.              |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WILL BE INFORMED.                                 |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021