Event Notification Report for April 28, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           04/27/2000 - 04/28/2000

                              ** EVENT NUMBERS **

36809  36924  36934  36935  36936  36937  

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   36809       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  U.S. ARMY                            |NOTIFICATION DATE: 03/17/2000|
|LICENSEE:  U.S. ARMY                            |NOTIFICATION TIME: 15:53[EST]|
|    CITY:  ROCK ISLAND              REGION:  3  |EVENT DATE:        03/17/2000|
|  COUNTY:                            STATE:  IL |EVENT TIME:        12:00[CST]|
|LICENSE#:  12-00722-06           AGREEMENT:  Y  |LAST UPDATE DATE:  04/27/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOHN JACOBSON        R3      |
|                                                |AL BELISLE           R2      |
+------------------------------------------------+DON COOL             NMSS    |
| NRC NOTIFIED BY:  JEFF HAVENNER                |CHARLES MILLER       IRO     |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DISCOVERY THAT AN M43A1 CHEMICAL AGENT DETECTOR CELL MODULE CONTAINING 250   |
| �Ci OF AMERICIUM-241 HAD BEEN MISSING FROM FT. BRAGG (NORTH CAROLINA) SINCE  |
| APRIL 1996                                                                   |
|                                                                              |
| Late yesterday afternoon (03/16/00), representatives from Ft. Bragg, North   |
| Carolina, requested the U.S. Army in Rock Island, Illinois, to help trace    |
| files for documentation regarding a cell module that was discovered to be    |
| missing from an M43A1 chemical agent detector.  (The cell module contained   |
| 250 �Ci of americium-241.)  The most recent documentation found related to   |
| the missing cell module indicated that it was last seen at Ft. Bragg in      |
| April of 1996.  More recent paperwork has not yet been found.  The licensee  |
| determined this event to reportable at approximately 1200 CST today          |
| (03/17/00).                                                                  |
|                                                                              |
| The licensee hypothesized that the M43A1 chemical agent detector may have    |
| been turned into a maintenance unit at some point.  If the device tested     |
| with bad air flow, the maintenance unit could have replaced several items    |
| including the cell module.  At this time, it is believed that the cell       |
| module in question may have been removed (without any paperwork) and that    |
| the device may have been returned without a replacement cell module          |
| installed.                                                                   |
|                                                                              |
| The licensee stated that there does not appear to be any likelihood that the |
| general public will get involved with this issue.  The licensee plans to     |
| submit a 30-day written report to the NRC Region 3 office.  (Call the NRC    |
| operations officer for licensee contact information.)                        |
|                                                                              |
| * * * UPDATE AT 1420 ON 03/30/00 BY MOHS RECEIVED BY WEAVER * * *            |
|                                                                              |
| The module was found on March 23, 2000.  The Operations Center notified the  |
| R3DO (Gardner) and R2DO (Caudle) and NMSS (Sherbini).                        |
|                                                                              |
| ***** UPDATE AT 1631 ON 04/27/00 FROM JEFF HAVENNER TO LEIGH TROCINE *****   |
|                                                                              |
| Based on a paper trail, the missing item was located at a Defense Logistics  |
| Agency (DLA) facility in Anniston, Alabama.  The M43A1 chemical agent        |
| detector cell module was non-functional and had been removed during          |
| maintenance.  It was then turned in through channels and sent to this depot  |
| facility.                                                                    |
|                                                                              |
| The NRC operations officer notified the R3DO (Shear), R2DO (Fredrickson),    |
| and NMSS EO (Cool).                                                          |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36924       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY                   REGION:  2  |NOTIFICATION DATE: 04/24/2000|
|    UNIT:  [1] [] []                 STATE:  AL |NOTIFICATION TIME: 16:26[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        04/24/2000|
+------------------------------------------------+EVENT TIME:        12:53[CDT]|
| NRC NOTIFIED BY:  WES CUMBEE                   |LAST UPDATE DATE:  04/27/2000|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ANN BOLAND           R2      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AUTOMATIC START OF THE PENETRATION ROOM FILTRATION SYSTEM DURING MAINTENANCE |
| ACTIVITIES.                                                                  |
|                                                                              |
| Maintenance investigation of a  high vibration on "1B" Spent Fuel Pool       |
| Exhaust fan resulted in the trip of the Spent Fuel Pool ventilation and      |
| subsequent autostart of the Penetration Room Filtration System.  All systems |
| operated as required.                                                        |
|                                                                              |
| Operations restarted the Spent Fuel Pool ventilation and secured the         |
| Penetration Room Filtration System.                                          |
|                                                                              |
| An investigation into this event is in progress.                             |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
|                                                                              |
| ***** UPDATE AT 1357 EDT ON 04/27/00 FROM VAUDY HOLLY, JR. TO LEIGH TROCINE  |
| *****                                                                        |
|                                                                              |
| The licensee is retracting this event notification.  The following text is a |
| portion of a facsimile received from the licensee:                           |
|                                                                              |
| "This event has been evaluated further and determined to be an invalid       |
| actuation based on 10 CFR 50.72(b)(2)(ii)(B)(3)(iv) and (v).  An invalid     |
| actuation of the fuel building ventilation system or auxiliary building      |
| ventilation system is not reportable."                                       |
|                                                                              |
| "The accident analysis for fuel handling accidents in the spent fuel pool    |
| (SFP) credits the high radiation signal initiation of SFP ventilation        |
| isolation and penetration room filtration (PRF) system start.  The low       |
| differential pressure start of the PRF system is not credited; therefore,    |
| PRF system actuation in the absence of a high radiation signal is not an     |
| [engineered safety feature (ESF)] actuation.  For the purposes of 10 CFR     |
| 50.72, this is an invalid actuation."                                        |
|                                                                              |
| The licensee notified the NRC resident inspector.  The NRC operations        |
| officer notified the R2DO (Fredrickson).                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   36934       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 04/27/2000|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 12:45[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        05/23/1998|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        06:13[CDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  04/27/2000|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |GARY SHEAR           R3      |
|  DOCKET:  0707001                              |SCOTT MOORE          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  THOMAS WHITE                 |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|OCBB 76.120(c)(2)(ii)    EQUIP DISABLED/FAILS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HISTORICAL REPORT OF THE DISCOVERY OF A FAULT CONDITION ON THREE MODULES ON  |
| THE 'X' CRITICALITY ACCIDENT ALARM SYSTEM CLUSTER DURING 1998 (24-HOUR       |
| REPORT)                                                                      |
|                                                                              |
| The following text is a portion of a facsimile received from Paducah:        |
|                                                                              |
| "At 0613 [CDT] on 05/23/98, the PSS was informed of a trouble alarm on C-337 |
| Criticality Accident Alarm System (CAAS) 'X' cluster.  Investigation of      |
| trouble alarm revealed that all three modules on [the] 'X' CAAS cluster were |
| in a 'Fault' condition.  The cluster was reset, and the Fault condition      |
| cleared.  This condition was not reported as an event in which equipment     |
| required by the [Technical Safety Requirement (TSR)] is disabled or fails to |
| function as designed as required by 10 CFR 76.120(c)(2).  This event was     |
| found during the investigation of Notification Worksheet No. 36880, which    |
| occurred on 04/12/00.  [The] 'X' CAAS cluster was in this 'Fault' condition  |
| from 0613 [CDT] until 0722 [CDT on 05/23/98].  During this time, an area in  |
| the Southeast corner of C-337, which contains a [Department of Energy (DOE)] |
| Material Storage Area (DMSA) that holds 55-gallon drums of potentially       |
| fissile material, was without operable CAAS coverage."                       |
|                                                                              |
| "This event should have been reported under 10 CFR 76.120(c)(2) as an event  |
| in which equipment required by the TSR is disabled or fails to function as   |
| designed."                                                                   |
|                                                                              |
| This issue was determined to be reportable yesterday afternoon.              |
|                                                                              |
| Paducah personnel notified the NRC resident inspector.                       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   36935       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NRC REGION 1 OFFICE                  |NOTIFICATION DATE: 04/27/2000|
|LICENSEE:  DAVID BLACKMORE & ASSOCIATES         |NOTIFICATION TIME: 13:48[EDT]|
|    CITY:  POTTSTOWN                REGION:  1  |EVENT DATE:        04/27/2000|
|  COUNTY:                            STATE:  PA |EVENT TIME:             [EDT]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  04/27/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JAMES NOGGLE         R1      |
|                                                |SCOTT MOORE          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES NOGGLE (R1DO)          |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NDAM                     DAMAGED GAUGE/DEVICE   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DAVID BLACKMORE & ASSOCIATES REPORT TO NRC REGION 1 REGARDING A CRUSHED SOIL |
| DENSITY GAUGE IN POTTSTOWN, PENNSYLVANIA                                     |
|                                                                              |
| At 1345 on 04/27/00, Joe Hughes (the radiation safety officer at David       |
| Blackmore & Associates) notified the NRC Region 1 office that a soil density |
| gauge was crushed at a construction site in Pottstown, Pennsylvania, near    |
| Porter Road.  Mr. Hughes was informed of the event and was en route to the   |
| job site at the time of this notification to the NRC Region 1 office.  Mr.   |
| Hughes called the NRC Region 1 Office to ask advice and was not aware of the |
| event specifics.  The NRC Region 1 office (Noggle) subsequently notified the |
| NRC operations center.                                                       |
|                                                                              |
| The R1DO (James Noggle) stated that the NRC Office of Nuclear Materials      |
| Safety and Safeguards (George Pangburn and Judith Joustra) had been          |
| informed.                                                                    |
|                                                                              |
| (Call the NRC operations office for licensee contact information.)           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36936       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FITZPATRICK              REGION:  1  |NOTIFICATION DATE: 04/27/2000|
|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 14:42[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        04/27/2000|
+------------------------------------------------+EVENT TIME:        10:50[EDT]|
| NRC NOTIFIED BY:  BOB STEIGERWALD              |LAST UPDATE DATE:  04/27/2000|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JAMES NOGGLE         R1      |
|10 CFR SECTION:                                 |FEMA, DOE, USDA, HHS FAX     |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |EPA, DOT (via NRC)   FAX     |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       90       Power Operation  |90       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - STATE DEC AND U.S. COAST GUARD NOTIFIED OF SMALL OIL DISCHARGE INTO LAKE   |
| ONTARIO -                                                                    |
|                                                                              |
| The licensee notified the New York State Department of Environmental         |
| Conservation (DEC), the U.S. Coast Guard, and the NRC Resident Inspector     |
| that approximately two ounces of oil had discharged from the plant storm     |
| drains into Lake Ontario.  The oil has dispersed.  The cause is unknown and  |
| being investigated by the licensee.                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36937       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM             REGION:  1  |NOTIFICATION DATE: 04/27/2000|
|    UNIT:  [2] [3] []                STATE:  PA |NOTIFICATION TIME: 17:03[EDT]|
|   RXTYPE: [2] GE-4,[3] GE-4                    |EVENT DATE:        04/27/2000|
+------------------------------------------------+EVENT TIME:        16:05[EDT]|
| NRC NOTIFIED BY:  JIM KOVALCHICK               |LAST UPDATE DATE:  04/27/2000|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JAMES NOGGLE         R1      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF POWER TO THE TECHNICAL SUPPORT CENTER                                |
|                                                                              |
| At 1505 on 04/27/00, power was lost to the Peach Bottom Technical Support    |
| Center (TSC) as a result of breaker malfunctions during planned electrical   |
| switching.  As of 1605, power had been out for greater than 1 hour           |
| constituting a loss of emergency assessment capability at the TSC.           |
|                                                                              |
| Assessment capability remains in the main control room and the Emergency     |
| Operations Facilities, and communication is still in tact between the        |
| control room and the TSC.  Troubleshooting and restoration activities by     |
| maintenance and operations personnel are currently in progress, and this     |
| condition does not affect either of the operating plants.                    |
|                                                                              |
| The licensee stated that power to the TSC was lost when two breakers failed  |
| to operate during performance of activities to restore power to a normal     |
| lineup following maintenance work on lines that do not normally affect the   |
| TSC.  (However, when this particular lineup change is made, it realigns the  |
| power going to the TSC.)  When the two breakers failed to operate, power at  |
| the TSC was lost.  The licensee stated that the loss of power affected the   |
| TSC only and that no other systems of facilities were affected.              |
|                                                                              |
| The licensee plans to notify the NRC resident inspector.                     |
|                                                                              |
| ***** UPDATE AT 1729 ON 04/27/00 FROM JIM KOVALCHICK TO LEIGH TROCINE *****  |
|                                                                              |
| Power was restored to the TSC at 1710 on 04/27/00.                           |
|                                                                              |
| The licensee notified the NRC resident inspector.  The NRC operations center |
| notified the R1DO (Noggle).                                                  |
+------------------------------------------------------------------------------+