Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for March 28, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/27/2000 - 03/28/2000

                              ** EVENT NUMBERS **

36771  36817  36836  36837  36838  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36771       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 03/08/2000|
|    UNIT:  [1] [] []                 STATE:  TX |NOTIFICATION TIME: 12:18[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/07/2000|
+------------------------------------------------+EVENT TIME:        13:00[CST]|
| NRC NOTIFIED BY:  MARILYN JOHNSON              |LAST UPDATE DATE:  03/27/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |KRISS KENNEDY        R4      |
|10 CFR SECTION:                                 |                             |
|NLTR                     LICENSEE 24 HR REPORT  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24-HOUR CONDITION OF LICENSE REPORT INVOLVING TECH SPEC REQUIREMENTS         |
|                                                                              |
| "On February 9, 2000, it was discovered that the Flux Multiplication Alarm   |
| (which is used to mitigate boron dilution accidents) was not functional. It  |
| was not recognized at that time that this caused the associated extended     |
| range neutron detector to be inoperable. If an extended range detector is    |
| inoperable in Modes 3, 4, and 5 the Technical Specifications requires that   |
| operations be suspended involving positive reactivity changes.               |
|                                                                              |
| "On March 1, 2000 at 0017 hours Unit 1 entered Mode 3 as part of a shutdown  |
| to support refueling activities.                                             |
| Immediately following Mode 3 entry testing was performed which involves      |
| raising control rods to perform drop                                         |
| testing. Raising control rods constitutes positive reactivity which is       |
| contrary to requirements of the Technical                                    |
| Specifications.                                                              |
|                                                                              |
| "This notification is being made pursuant to Operating License NPF-76        |
| Condition 2.G for operation or condition prohibited by Technical             |
| Specifications."                                                             |
|                                                                              |
| The licensee will inform the NRC resident inspector.                         |
|                                                                              |
| * * * UPDATE AT 1417 ON 03/27/00 BY KEN TAPLETT TO JOLLIFFE * * *            |
|                                                                              |
| Further licensee review determined that the extended range neutron detector  |
| in question had been operable during the positive reactivity change          |
| activity.  During the time of the original notification, the Flux            |
| Multiplication Alarm was thought to be non-functional.  A non-functional     |
| Flux Multiplication Alarm causes the associated extended range neutron       |
| detector to be inoperable.  It was determined that the Flux Multiplication   |
| Alarm was actually functional at the completion of surveillance testing      |
| conducted on February 9, 2000. The surveillance procedure requires an alarm  |
| reset prior to exiting the surveillance test which arms the Flux             |
| Multiplication Alarm circuit thus making it functional.  Although this step  |
| was performed on February 9, 2000, the performers did not recognize at the   |
| time that this corrected the perceived loss of alarm function.               |
|                                                                              |
| Prior to the February 9, 2000 surveillance test, the last satisfactory       |
| performance of the Flux Multiplication Alarm surveillance was conducted on   |
| November 16, 1999 with a grace period to March 10, 2000.  Unit 1 entered     |
| Mode 6 (where the requirement was no longer applicable) on March 3, 2000 and |
| has remained in that mode for a refueling and steam generator replacement    |
| outage.  A satisfactory surveillance test was conducted on March 16, 2000.   |
|                                                                              |
| The licensee plans to revise the test procedure to preclude recurrence of    |
| this event.                                                                  |
|                                                                              |
| Based upon the above justification, the licensee desires to retract this     |
| event.                                                                       |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| The NRC Operations Officer notified the R4DO Kriss Kennedy.                  |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36817       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: RIVER BEND               REGION:  4  |NOTIFICATION DATE: 03/20/2000|
|    UNIT:  [1] [] []                 STATE:  LA |NOTIFICATION TIME: 17:03[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        03/20/2000|
+------------------------------------------------+EVENT TIME:        15:05[CST]|
| NRC NOTIFIED BY:  TOM LYNCH                    |LAST UPDATE DATE:  03/27/2000|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LAWRENCE YANDELL     R4      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECURITY REPORT                                                              |
|                                                                              |
| A contact employee attempted to bring contraband into the Protected Area.    |
| Immediate compensatory actions were taken upon discovery. The licensee       |
| notified the NRC resident inspector. Contact the NRC Operations Center for   |
| additional details.                                                          |
|                                                                              |
| * * * UPDATE AT 1513 ON 03/27/00 FROM KIM AITKEN TO JOLLIFFE * * *           |
|                                                                              |
| Further licensee investigation revealed that there was no significant threat |
| to River Bend Station or the public and that the vendor employee had no      |
| malevolent intent.  After review of Reg Guide 5.62, NUREG 1304, and Generic  |
| Letter 91-03, the licensee has determined that this event is not reportable  |
| under 10CFR26, 10CFR50.72, 10CFR73.71, or 10CFR73, Appendix G.l.d criteria   |
| and thus, the licensee desires to retract this event.  The licensee has      |
| discussed this event with Region IV security personnel and the NRC Resident  |
| Inspector.  The NRC Operations Officer notified the R4DO Kriss Kennedy.      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36836       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 03/27/2000|
|    UNIT:  [] [2] []                 STATE:  GA |NOTIFICATION TIME: 09:17[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/27/2000|
+------------------------------------------------+EVENT TIME:        08:00[EST]|
| NRC NOTIFIED BY:  URQUHART                     |LAST UPDATE DATE:  03/27/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |THOMAS DECKER        R2      |
|10 CFR SECTION:                                 |                             |
|ADAS 50.72(b)(2)(i)      DEG/UNANALYZED COND    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FAILURE OF LOCAL LEAK RATE TEST.                                             |
|                                                                              |
| DURING LOCAL LEAK RATE TESTING(LLRT) OF THE "2G11-F004", DRYWELL FLOOR DRAIN |
| SUMP PRIMARY CONTAINMENT ISOLATION VALVE, IT WAS DETERMINED THAT THE VALVE   |
| LEAKS AT A RATE GREATER THAN 30,000 ACCM(ACTUAL CUBIC CENTIMETERS/MIN) WHICH |
| IS GREATER THAN THE PROCEDURAL LIMITS.  THIS IN COMBINATION WITH ITS         |
| COMPANION( IN SERIES) ISOLATION VALVE(2G11-F003) WHICH HAD FAILED A PREVIOUS |
| LLRT AND WAS REPAIRED, BUT FAILED ITS RETEST, RESULTED IN THE TECH SPEC      |
| LIMIT FOR 0.009L-SUB-A BEING  EXCEEDED FOR BYPASS LEAKAGE.   THE TEST WAS    |
| PERFORMED ON 3/26 AND WAS EVALUATED THIS MORNING.                            |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED.                                         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36837       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  FLORIDA BUREAU OF RADIATION CONTROL  |NOTIFICATION DATE: 03/27/2000|
|LICENSEE:  DUNKELBERGER ENGINEERING & TESTING   |NOTIFICATION TIME: 10:00[EST]|
|    CITY:  WEST PALM BEACH          REGION:  2  |EVENT DATE:        03/27/2000|
|  COUNTY:  PALM BEACH                STATE:  FL |EVENT TIME:             [EST]|
|LICENSE#:  2462-2 (FL)           AGREEMENT:  Y  |LAST UPDATE DATE:  03/27/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |THOMAS DECKER        R2      |
|                                                |BRIAN SMITH          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CHARLEY E. ADAMS (FL)        |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING RECOVERED TROXLER GAUGE                     |
|                                                                              |
| "Citizen found troxler gauge [containing 8mCi Cs-137 and 40mCi Am-241:Be]    |
| along road and took it to the Royal Palm Beach PD. Owner notified this       |
| office of missing gauge, was told of it's location [Intersection of 41 & 67  |
| in Royal Palm Beach], and then took possession. There was no damage to the   |
| gauge which was in a locked case. Owner said that the operator failed to     |
| secure the gauge to the truck when leaving a work site. Florida is           |
| investigating the incident [Florida Incident #FL00-054]."                    |
|                                                                              |
| The licensee lost the device on the morning of 3/27/00 when it fell off his  |
| truck due to not being properly secured.                                     |
|                                                                              |
| Call the Headquarters Operations Center for contact information.             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36838       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 03/27/2000|
|    UNIT:  [1] [2] []                STATE:  TN |NOTIFICATION TIME: 14:43[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/27/2000|
+------------------------------------------------+EVENT TIME:        10:08[EST]|
| NRC NOTIFIED BY:  TERRY KNUETTEL               |LAST UPDATE DATE:  03/27/2000|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |THOMAS DECKER        R2      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FITNESS FOR DUTY EVENT -                                                     |
|                                                                              |
| A temporary employee foreman tested positive for illegal drugs during a      |
| random drug test.  The licensee terminated the employee's plant access       |
| authorization.  Contact the NRC Operations Officer for additional details.   |
| The licensee notified the NRC  Resident Inspector.                           |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021