Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for November 18, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           11/17/1999 - 11/18/1999

                              ** EVENT NUMBERS **

36330  36445  36446  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36330       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  US AIR FORCE                         |NOTIFICATION DATE: 10/22/1999|
|LICENSEE:  US AIR FORCE                         |NOTIFICATION TIME: 07:39[EDT]|
|    CITY:  MACON                    REGION:  2  |EVENT DATE:        10/21/1999|
|  COUNTY:                            STATE:  GA |EVENT TIME:        16:53[EDT]|
|LICENSE#:  42-32539-01AF         AGREEMENT:  Y  |LAST UPDATE DATE:  11/17/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |KERRY LANDIS         R2      |
|                                                |LINDA SMITH          R4      |
+------------------------------------------------+CHARLEY HAUGHNEY     NMSS    |
| NRC NOTIFIED BY:  MAJ. WROBEL                  |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE AIR FORCE REPORTED THAT A LANTERN POD WAS LOST IN SHIPMENT               |
|                                                                              |
| A LANTERN POD (INFRARED IMAGING POD) CONTAINING TWO 4 MICROCURIES OF         |
| AMERICIUM-241 SOURCES WAS LOST IN A SHIPMENT FROM KIRKLAND AFB, NEW MEXICO   |
| TO ROBINS AFB, GEORGIA.  THE DEVICE WAS AN AMERSHAM MODEL AMM.7.  FEDEX WAS  |
| THE CARRIER FOR THIS SHIPMENT AND THE AIRBILL NUMBER IS 5654077161.  THE     |
| SHIPMENT WAS DETERMINED TO BE LOST AT THE FEDEX  DISTRIBUTION CENTER IN      |
| MACON, GA.  THE DEVICE IS STILL BEING TRACKED BY FEDEX.                      |
|                                                                              |
| * * *UPDATE AT 1120 ON 11/17/99 BY WROBEL, TAKEN BY WEAVER * * *             |
| The lantern pod was received at Robins AFB, but had not been properly logged |
| in, hence the lost shipment report.  The Ops Center notified the R2DO        |
| (MCALPINE); R4DO(JONES); NMSS(PICCONE).                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36445       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 11/17/1999|
|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 06:59[EST]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        11/17/1999|
+------------------------------------------------+EVENT TIME:        04:25[CST]|
| NRC NOTIFIED BY:  ELLIS PFEFFER                |LAST UPDATE DATE:  11/17/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |THOMAS KOZAK         R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       98       Power Operation  |98       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR CORE ISOLATION COOLING (RCIC) FLOW INDICATOR FAILED LOW              |
|                                                                              |
|                                                                              |
| The RCIC system was declared inoperable due to a flow indicator failing      |
| downscale (below zero).  The indication was noted while the system was in    |
| standby.  The plant is in a 14 day LCO.  Troubleshooting efforts are in      |
| progress.  The licensee notified the NRC resident.                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36446       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GRAND GULF               REGION:  4  |NOTIFICATION DATE: 11/18/1999|
|    UNIT:  [1] [] []                 STATE:  MS |NOTIFICATION TIME: 06:20[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        11/18/1999|
+------------------------------------------------+EVENT TIME:        03:05[CST]|
| NRC NOTIFIED BY:  CHRIS MILLER                 |LAST UPDATE DATE:  11/18/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BILL JONES           R4      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ESF ACTUATION - INADVERTENT LEVEL ONE ACTUATION WHILE SHUTDOWN               |
|                                                                              |
| While venting and filling the control rod drive system, an invalid level 1   |
| signal was generated due to an isolation valve leaking past its seat and     |
| spiking the transmitters.  Because the plant is in a refueling outage, the   |
| majority of Division 1 equipment was removed from service, the Division 1    |
| drywell purge compressor did actuate from the invalid signal.   Additionally |
| the load shedding and sequencing for Division 1 actuated.  The RHR 'A'       |
| shutdown cooling pump and service water pump were shed and reloaded.  The    |
| signal also caused the opening of the RHR 'A' injection valve and  started   |
| the Division 1 diesel generator.   Shutdown cooling flow was never entirely  |
| lost as the RHR pump re-started after 5 seconds.                             |
|                                                                              |
| All components and actuations have been reset to their pre-existing          |
| configurations.                                                              |
|                                                                              |
| The licensee will notify the NRC resident inspector.                         |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021