Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for August 3, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           08/02/1999 - 08/03/1999

                              ** EVENT NUMBERS **

35980  35981  35982  35983  35984  35985  35986  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35980       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY                    REGION:  2  |NOTIFICATION DATE: 08/02/1999|
|    UNIT:  [1] [2] []                STATE:  VA |NOTIFICATION TIME: 09:58[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        08/02/1999|
+------------------------------------------------+EVENT TIME:        09:15[EDT]|
| NRC NOTIFIED BY:  BILL WEBSTER                 |LAST UPDATE DATE:  08/02/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROBERT HAAG          R2      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DISCOVERY THAT PREVENTS A 3 HOUR FIRE BARRIER FROM MEETING ITS DESIGN        |
|                                                                              |
| "On 7/26/99 a 3-5/8 inch gap approximately 7 feet long was identified to     |
| exist between the Auxiliary Building (Fire Area #17) and the #2 Mechanical   |
| Equipment Room (Fire Area #31).  A deviation report was submitted on the     |
| above date for this condition.  On 8/2/99 following additional evaluation by |
| the plant staff, it was determined that this gap would have prevented this   |
| fire barrier from meeting its 3-hour fire rating.  This condition is         |
| considered to have existed since original design and construction of the     |
| plant.  This condition constitutes a condition outside the Appendix R design |
| basis of the plant.  This condition is being reported pursuant to            |
| 10CFR5O.72(b)(1)(ii)(B).  A continuous fire watch has been established on    |
| one side of the affected fire barrier as a compensatory measure in           |
| accordance with the station Appendix R Program."                             |
|                                                                              |
| The discovery occurred during a quarterly inspection in an area that was     |
| difficult to access normally.  The corrective actions have been determined   |
| and will be completed before the fire watch is removed.                      |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35981       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PALISADES                REGION:  3  |NOTIFICATION DATE: 08/02/1999|
|    UNIT:  [1] [] []                 STATE:  MI |NOTIFICATION TIME: 12:03[EDT]|
|   RXTYPE: [1] CE                               |EVENT DATE:        08/01/1999|
+------------------------------------------------+EVENT TIME:        15:25[EDT]|
| NRC NOTIFIED BY:  MALONE                       |LAST UPDATE DATE:  08/02/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GEOFFREY WRIGHT      R3      |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       99       Power Operation  |99       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DROWNING FATALITY IN LAKE MICHIGAN                                           |
|                                                                              |
| THE LICENSEE MADE AN INFORMATION CALL OF A DROWNING FATALITY IN LAKE         |
| MICHIGAN WHICH OCCURRED NEAR THE PALISADES PLANT.  ACCESS TO THE VICTIM BY   |
| EMERGENCY VEHICLE WAS OBTAINED THROUGH THE PLANT PROTECTED AREA.  THE        |
| LICENSEE DID NOT ISSUE ANY PRESS RELEASES, BUT THE MEDIA DID MENTION THE     |
| PLANT IN ITS REPORTS.                                                        |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   35982       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 08/02/1999|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 14:17[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        08/02/1999|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        12:22[CDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  08/02/1999|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |MARK RING            R3      |
|  DOCKET:  0707001                              |DON COOL             NMSS    |
+------------------------------------------------+AARON DANIS          IAT     |
| NRC NOTIFIED BY:  JONES                        |JOSEPH GIITTER       IRO     |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BOMB THREAT AT LANDFILL                                                      |
|                                                                              |
| THE LICENSEE REPORTED AN UNCLASSIFIED EMERGENCY, AS A COURTESY NOTIFICATION, |
| THAT THERE WAS  A POTENTIAL BOMB THREAT, WHICH HAS NOT YET REACHED THE       |
| CREDIBLE STATE, AT A LANDFILL NORTH OF THE PLANT.  THIS THREAT IS BASED ON   |
| UNIDENTIFIED AND SUSPICIOUS ITEMS BEING FOUND AT THE LANDFILL.  THE LOCAL    |
| POLICE BOMB SQUAD IS RESPONDING.  NO PROTECTIVE ACTION IS RECOMMENDED AT     |
| THIS TIME, SIRENS HAVE NOT BEEN ACTIVATED, NO EAS MESSAGE WAS REQUIRED AND   |
| NO RELEASES HAVE OCCURRED.                                                   |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED ALONG WITH THE COUNTY AND STATE DISASTER |
| AND EMERGENCY SERVICES, AND DOE.                                             |
|                                                                              |
| *** UPDATE ON 8/2/99 @ 1526 BY JONES TO GOULD ***                            |
|                                                                              |
| THE POLICE BOMB SQUAD WILL EVALUATE THE SUSPICIOUS ITEMS AT THE SITE.        |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED.                                         |
|                                                                              |
| *** UPDATE ON 8/2/99 @ 1617 BY JONES TO GOULD ***                            |
|                                                                              |
| THE POLICE BOMB SQUAD DETERMINED THE CONTAINERS AT THE LAND FILL CONTAINED   |
| ANTIFREEZE,  THE EMERGENCY WAS TERMINATED AT 1458 CDT.                       |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED.   THE NMSS EO(MOORE) AND THE REG 3      |
| RDO(RING) AND  DANIS(IAT) WERE NOTIFIED.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35983       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRAIDWOOD                REGION:  3  |NOTIFICATION DATE: 08/02/1999|
|    UNIT:  [1] [2] []                STATE:  IL |NOTIFICATION TIME: 16:43[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        08/02/1999|
+------------------------------------------------+EVENT TIME:        14:45[CDT]|
| NRC NOTIFIED BY:  DORAZIO                      |LAST UPDATE DATE:  08/02/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MARK RING            R3      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOST SECURITY KEY. COMPENSATORY MEASURES TAKEN.  SEE LOG FOR ADDITIONAL      |
| INFORMATION.                                                                 |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED.                                         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35984       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COMANCHE PEAK            REGION:  4  |NOTIFICATION DATE: 08/02/1999|
|    UNIT:  [1] [2] []                STATE:  TX |NOTIFICATION TIME: 17:21[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        08/02/1999|
+------------------------------------------------+EVENT TIME:        15:53[CDT]|
| NRC NOTIFIED BY:  SEWEEL                       |LAST UPDATE DATE:  08/02/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |TOM STETKA           R4      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PLATFORM GRATING CLAMPS(FASTENERS) APPEAR NOT TO BE SEISMICALLY QUALIFIED.   |
|                                                                              |
| THE LICENSEE HAS DETERMINED THAT THE PLATFORM GRATING CLAMPS DO NOT APPEAR   |
| TO HAVE BEEN QUALIFIED FOR THE REQUIREMENTS OF A SEISMIC CATEGORY 1          |
| COMPONENT WHEN LOADED.  WITH THE GRATINGS UNLOADED, HOWEVER, THIS CONDITION  |
| DOES NOT AFFECT THE ABILITY OF SAFETY RELATED SYSTEMS TO PERFORM THERE       |
| INTENDED FUNCTIONS DURING A DESIGN BASIS EARTHQUAKE.   ENGINEERING IS        |
| CONTINUING TO EVALUATE THIS CONDITION.                                       |
|                                                                              |
| THE RESIDENT INSPECTOR WILL BE NOTIFIED                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35985       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LIMERICK                 REGION:  1  |NOTIFICATION DATE: 08/02/1999|
|    UNIT:  [1] [2] []                STATE:  PA |NOTIFICATION TIME: 23:46[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        08/02/1999|
+------------------------------------------------+EVENT TIME:        22:35[EDT]|
| NRC NOTIFIED BY:  JOHN HUNTER                  |LAST UPDATE DATE:  08/02/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD BARKLEY      R1      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SAFEGUARDS SYSTEM DEGRADATION RELATED TO VITAL AREA BOUNDARY.  COMPENSATORY  |
| MEASURES TAKEN UPON DISCOVERY.  THE LICENSEE INFORMED THE NRC RESIDENT       |
| INSPECTOR.  CONTACT THE OPERATIONS CENTER FOR ADDITIONAL DETAILS.            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   35986       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  U.S. STEEL, GARY WORKS               |NOTIFICATION DATE: 08/03/1999|
|LICENSEE:  U.S. STEEL                           |NOTIFICATION TIME: 04:55[EDT]|
|    CITY:  GARY                     REGION:  3  |EVENT DATE:        08/02/1999|
|  COUNTY:  LAKE                      STATE:  IN |EVENT TIME:        20:58[CDT]|
|LICENSE#:  GA458-3G              AGREEMENT:  N  |LAST UPDATE DATE:  08/03/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MARK RING            R3      |
|                                                |CHARLEY HAUGHNEY     NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  DEAN LARSON                  |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NDAM                     DAMAGED GAUGE/DEVICE   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POSSIBLE DAMAGED THICKNESS GAUGE                                             |
|                                                                              |
| The licensee reported a strip break on the #6 continuous galvanizing line    |
| struck a NDS Model #200 (Serial #2061T) thickness gauge and knocked it from  |
| its mount.  The gauge contains a sealed source of 2 curies of Americium-241. |
| The area was isolated and a survey and wipe test indicated normal readings   |
| as indicated by recent surveys.  The licensee notified its contractor, Val   |
| Met, who will actually go the plant to move the gauge and verify any actual  |
| damage to the gauge.  Val Met is the company that replaced NDS.              |
|                                                                              |
| No injuries, personnel exposures, or contamination occurred in this          |
| incident.                                                                    |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021