Event Notification Report for April 19, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           04/16/1999 - 04/19/1999

                              ** EVENT NUMBERS **

35597  35598  35599  35600  35601  35602  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   35597       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  UNITED AIRLINES, NEWARK, NJ          |NOTIFICATION DATE: 04/16/1999|
|LICENSEE:  AMERSHAM                             |NOTIFICATION TIME: 04:58[EDT]|
|    CITY:  NEWARK                   REGION:  1  |EVENT DATE:        04/16/1999|
|  COUNTY:                            STATE:  NJ |EVENT TIME:        02:45[EDT]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  04/16/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |DAN HOLODY           R1      |
|                                                |GEORGE PANGBURN      R1      |
+------------------------------------------------+JOHN JACOBSON        R3      |
| NRC NOTIFIED BY:  LTJG EBNER, DOT NRC          |JOHN SURMEIER        NMSS    |
|  HQ OPS OFFICER:  DICK JOLLIFFE                |FRED COMBS           NMSS    |
+------------------------------------------------+FRANK CONGEL         IRO     |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - LEAKING Tc-99m GENERATOR CONTAMINATED AIRCRAFT AT NEWARK INTERNATIONAL     |
| AIRPORT -                                                                    |
|                                                                              |
| At 0437 on 04/16/99, Bob Hayes of United Airlines notified the Department of |
| Transportation (DOT) National Response Center that a leaking container of    |
| radioactive solid sodium molybdate (DOT Yellow III) had spilled inside an    |
| aircraft that had landed at Newark International Airport (National Response  |
| Center Incident Report #480533).  Approximately 0.01 microcuries of material |
| had spilled.  The spill was cleaned up using an industrial cleaner, with no  |
| residual contamination detected.  LTJG Ebner of the National Response Center |
| notified the NRC Headquarters Operations Officer (HOO) and the NJ Department |
| of Environmental Protection (NJ DEP).                                        |
|                                                                              |
| At 0654 on 04/16/99, John Feney of the NJ DEP informed the NRC HOO that the  |
| container was a Tc-99m generator with a 15-curie radiation source and that   |
| he was preparing to respond to the airport.  He was conferenced with Region  |
| I (Dan Holody) and NMSS (John Surmeier and Fred Combs).  The generator was   |
| enroute from Amersham Holdings, Inc., located in Arlington Heights, IL, to   |
| Amersham Pharmacy located in Livingston, NJ.                                 |
|                                                                              |
| At 0721 on 04/16/99, John Marzocca of the Amersham Pharmacy located in       |
| Livingston, NJ, contacted the NRC HOO to provide additional information      |
| regarding the event.  He was conferenced with Region I (Dan Holody, George   |
| Pangburn, and Duncan White); Region III (John Jacobson); and NMSS (Fred      |
| Combs and John Surmeier).                                                    |
|                                                                              |
| At 0950 on 04/16/99, Joe Moon of Del-Med Trucking, Inc. (the package         |
| shipper), located in South Plainfield, NJ, notified the DOT National         |
| Response Center that the surface of the Type 'A' package measured 11,000 dpm |
| per 300 sq cm (0.0051 microcuries) upon arrival at the Amersham Pharmacy     |
| located in Livingston, NJ (National Response Center Incident Report          |
| #480547).  The exposed driver and the truck were recalled and                |
| decontaminated, and the aircraft has been impounded and is being             |
| decontaminated.   Mr. Winters of the National Response Center notified the   |
| NRC HOO and the NJ DEP.                                                      |
|                                                                              |
| (Contact the NRC HOO for addresses and telephone numbers.)                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   35598       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  STERIGENICS INTERNATIONAL            |NOTIFICATION DATE: 04/16/1999|
|LICENSEE:  STERIGENICS INTERNATIONAL            |NOTIFICATION TIME: 05:38[EDT]|
|    CITY:  ROCKAWAY                 REGION:  1  |EVENT DATE:        04/16/1999|
|  COUNTY:                            STATE:  NJ |EVENT TIME:        02:15[EDT]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  04/16/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |DAN HOLODY           R1      |
|                                                |JOHN SURMEIER        NMSS    |
+------------------------------------------------+FRANK CONGEL         IRO     |
| NRC NOTIFIED BY:  STEVEN ZIMMERMAN             |                             |
|  HQ OPS OFFICER:  DICK JOLLIFFE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|MAAA 36.83(a)(1)         UNSHIELD STUCK SOURCE  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| -RADIATION SOURCE STUCK IN UNSHIELDED POSITION AT A COMMERCIAL IRRADIATOR    |
| FOR 3 HOURS                                                                  |
|                                                                              |
| AT 0215 ON 04/16/99, WHILE IRRADIATING MINERAL SUPPLEMENTS AT A COMMERCIAL   |
| IRRADIATOR, THE RADIATION SOURCE RACK BECAME STUCK IN THE UP (UNSHIELDED)    |
| POSITION.  THE SOURCE RACK CONTAINS A 2.6-MILLION-CURIE Co-60 SOURCE.  AT    |
| 0515, THE LICENSEE SUCCESSFULLY LOWERED THE SOURCE RACK TO ITS SHIELDED      |
| POSITION AND STOPPED ALL OPERATIONS.  NO PERSONNEL EXPOSURES OCCURRED AS A   |
| RESULT OF THIS EVENT.                                                        |
|                                                                              |
| THE LICENSEE PREVIOUSLY ENCOUNTERED A STUCK SOURCE IN AUGUST 1995.           |
| MAINTENANCE ACTIVITIES HAD BEEN PERFORMED ON THE SOURCE RACK ON APRIL 6 AND  |
| 7, 1999.  THE LICENSEE IS INVESTIGATING THIS STUCK SOURCE EVENT AND PLANS TO |
| SUBMIT A WRITTEN REPORT OF THIS EVENT TO NRC REGION 3 WITHIN 30 DAYS.        |
|                                                                              |
| ******************** UPDATE AT 2006 ON 04/16/99 FROM ZIMMERMAN TO TROCINE    |
| ********************                                                         |
|                                                                              |
| The licensee has been in contact with NRC Region 1 (John McGrath) regarding  |
| corrective actions.                                                          |
|                                                                              |
| From 1815 until 2100, the licensee tested the source rack for up and down    |
| motion almost 20 times.  The licensee also performed safety interlock        |
| testing, and the results were satisfactory.  In addition, all of the         |
| bushings were replaced, and all of the guide cables for the source racks     |
| were tightened.                                                              |
|                                                                              |
| The licensee plans to restart tonight.                                       |
|                                                                              |
| As requested by the licensee, the NRC operations officer notified NRC Region |
| 1 (George Pangburn and John McGrath).  The NRC operations officer also       |
| notified the R1DO (Holody).                                                  |
|                                                                              |
| (Call the NRC operations officer for a licensee contact telephone number.)   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   35599       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  U.S. ARMY (ACALA)                    |NOTIFICATION DATE: 04/16/1999|
|LICENSEE:  U.S. ARMY (ACALA)                    |NOTIFICATION TIME: 10:44[EDT]|
|    CITY:  GERMANY                  REGION:     |EVENT DATE:        01/15/1999|
|  COUNTY:                            STATE:     |EVENT TIME:        12:00[EST]|
|LICENSE#:  12-00722-06           AGREEMENT:  N  |LAST UPDATE DATE:  04/16/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOHN JACOBSON        R3      |
|                                                |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JEFF HAVENNER                |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THREE M43A1 CHEMICAL AGENT DETECTORS MISPLACED IN GERMANY                    |
|                                                                              |
| The U.S. Army reported that three M43A1 chemical agent detectors, each       |
| containing 250 �Ci of Am-241, had been misplaced between mid-December 1998   |
| and mid-January 1999.  The detectors were issued to the 324th Signal         |
| Company, and they were being deployed to an unspecified location.  The       |
| paperwork regarding these detectors was not completed properly, and the Army |
| believes that they are still in possession of the detectors.  The U.S. Army  |
| plans to contact the German government regarding this event.                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35600       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 04/17/1999|
|    UNIT:  [] [] [3]                 STATE:  IL |NOTIFICATION TIME: 11:58[EDT]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        04/17/1999|
+------------------------------------------------+EVENT TIME:        09:59[CDT]|
| NRC NOTIFIED BY:  DAVE SLAGER                  |LAST UPDATE DATE:  04/17/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOHN JACOBSON        R3      |
|10 CFR SECTION:                                 |                             |
|ADEG 50.72(b)(1)(ii)     DEGRAD COND DURING OP  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|                                                   |                          |
|3     N          Y       99       Power Operation  |99       Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FAILURE OF A PRIMARY CONTAINMENT AIR SAMPLE RETURN ISOLATION VALVE TO MEET   |
| MAXIMUM INSERVICE TEST STROKE-TIME REQUIREMENTS                              |
|                                                                              |
| While performing quarterly valve stroke-time testing on Unit 3, a primary    |
| containment air sample return isolation valve exceeded its specified maximum |
| stroke-time limit.  The sample return line was isolated in accordance with   |
| Technical Specification 3.7.D for primary containment isolation valves, and  |
| this action satisfied the 4-hour limiting condition for operation action     |
| statement requirements.  The second in-line primary containment isolation    |
| system valve remains operable.                                               |
|                                                                              |
| The licensee stated that no other valves failed to meet the maximum          |
| stroke-time limits.  The licensee also stated that, during a test that was   |
| performed last month, the valve in question was identified as being in the   |
| 'Alert' time range for inservice test timing requirements and that it was    |
| being tested per the required increased testing frequency.  Corrective       |
| actions are being initiated, and troubleshooting activities are in           |
| progress.                                                                    |
|                                                                              |
| The licensee plans to notify the NRC resident inspector.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35601       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 04/18/1999|
|    UNIT:  [1] [] []                 STATE:  PA |NOTIFICATION TIME: 01:41[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        04/17/1999|
+------------------------------------------------+EVENT TIME:        22:14[EDT]|
| NRC NOTIFIED BY:  DON ROLAND                   |LAST UPDATE DATE:  04/18/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |DAN HOLODY           R1      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT 1 HAD LESS THAN THREE OPERABLE DIESEL GENERATORS FOR A SHORT PERIOD OF  |
| TIME.                                                                        |
|                                                                              |
| During restoration from LOCA/LOOP Division 2 testing on Unit 2, which is     |
| shutdown, operators inadvertently placed the 'D' Diesel Generator            |
| Synchronization Auto Control Select Switch to Bypass with the 'B' Diesel     |
| Generator already in Bypass per plant procedures.  This action requires the  |
| diesel be declared inoperable.  The action was immediately identified, and   |
| the switch on the 'D' Diesel was returned to Normal.  The total time that    |
| two diesel generators were inoperable was less than 1 minute.  This left     |
| Unit 1 with only the 'A' and 'C' Diesel Generators operable.                 |
|                                                                              |
| The licensee plans to notify the NRC resident inspector.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35602       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: RIVER BEND               REGION:  4  |NOTIFICATION DATE: 04/18/1999|
|    UNIT:  [1] [] []                 STATE:  LA |NOTIFICATION TIME: 21:08[EDT]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        04/18/1999|
+------------------------------------------------+EVENT TIME:        16:47[CDT]|
| NRC NOTIFIED BY:  RUSS GODWIN                  |LAST UPDATE DATE:  04/18/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LINDA SMITH          R4      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CLOSURE OF THE HIGH PRESSURE CORE SPRAY DIESEL GENERATOR OUTPUT BREAKER IN   |
| RESPONSE TO AN UNDERVOLTAGE CONDITION WHEN THE NORMAL SUPPLY BREAKER TRIPPED |
| OPEN                                                                         |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "At 1647 [CDT], on April 18, 1999, with the plant in Mode 5 (Refueling), the |
| High Pressure Core Spray [(HPCS)] Diesel Generator [(DG)] output breaker     |
| closed in response to an undervoltage condition on its safety-related        |
| 4.16-kV bus."                                                                |
|                                                                              |
| "At the time of the event, the HPCS DG was already running, unloaded, as     |
| part of a planned test sequence.  The undervoltage condition occurred when   |
| the normal supply breaker tripped open.  The HPCS DG output breaker operated |
| as designed, and the HPCS DG supplied its safety-related bus."               |
|                                                                              |
| "The HPCS system was inoperable when this event occurred and is not required |
| to be operable in the current plant mode."                                   |
|                                                                              |
| "The cause of the trip of the normal supply breaker is not known.  [The]     |
| plant staff is investigating this event, and the cause will be corrected     |
| prior to returning the HPCS system to service."                              |
|                                                                              |
| The licensee stated that all systems functioned as required in response to   |
| the undervoltage condition.  The licensee also stated that core alterations  |
| (fuel shuffle) are in progress.                                              |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+